Evaluation of the sensitivity of the Express View function in the Mirocam® capsule endoscopy software

Abstract Background: A new computer algorithm called Express-View has recently been introduced by Mirocam, but data concerning its application and efficacy are scarce. Objective: To evaluate the lesion detection rate, per-patient sensitivity and the diagnostic accuracy using Express-View. Methods: All patients who performed CE between January 2018 and June 2019, whose indication was obscure gastrointestinal bleeding (OGIB) and with findings on CE, were included. Lesions identified in conventional reading were selected and considered as reference. Results: Eighty-nine patients were included, 50.6% male, with a mean age of 68.4 years-old (±12.3). The Express-View mode detected 85.5% of lesions previously detected by conventional reading (524 out of 613). There were 89 missed lesions, mainly erosions or ulcers (44.9%) and angioectasias (38.2%). The lesion detection rate was found to be lower in the jejunum and ileum compared to extra-small bowel locations and duodenum (p = .04). Although Express-View had a per-patient sensitivity for all lesions of 56.2% and a per-patient sensitivity for all clinically significant lesions of 83.1%, it achieved a diagnostic accuracy of 91%. Conclusions: The per-patient sensitivity for all lesions was shown to be below expectations, although the lesion detection rate, the per-patient sensitivity for all clinically significant lesions, and the diagnostic accuracy were shown to be higher.

[1]  R. Pinho,et al.  Impact of the timing of capsule endoscopy in overt obscure gastrointestinal bleeding on yield and rebleeding rate - is sooner than 14 d advisable? , 2018, World journal of gastrointestinal endoscopy.

[2]  A. Eickhoff,et al.  Diagnosis of small-bowel pathology using paired capsule endoscopy with two different devices: a randomized study , 2007, Endoscopy.

[3]  Amy K Hara,et al.  A Meta-Analysis of the Yield of Capsule Endoscopy Compared to Other Diagnostic Modalities in Patients with Non-Stricturing Small Bowel Crohn's Disease , 2006, The American Journal of Gastroenterology.

[4]  R. Pinho,et al.  Yield of capsule endoscopy in obscure gastrointestinal bleeding: A comparative study between premenopausal and menopausal women , 2018, World journal of gastrointestinal endoscopy.

[5]  R. Weersma,et al.  Can we reduce capsule endoscopy reading times? , 2009, Gastrointestinal endoscopy.

[6]  R. Pinho,et al.  What is the long-term outcome of a negative capsule endoscopy in patients with obscure gastrointestinal bleeding? , 2015, Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva.

[7]  A. Hara,et al.  A Meta-Analysis of the Yield of Capsule Endoscopy Compared to Other Diagnostic Modalities in Patients with Obscure Gastrointestinal Bleeding , 2005, The American Journal of Gastroenterology.

[8]  M. Mascarenhas-Saraiva,et al.  Long-term rebleeding risk following endoscopic therapy of small-bowel vascular lesions with device-assisted enteroscopy , 2016, European journal of gastroenterology & hepatology.

[9]  Emanuele Rondonotti,et al.  Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline , 2015, Endoscopy.

[10]  J. Cotter,et al.  Endoscopic Scores for Evaluation of Crohn's Disease Activity at Small Bowel Capsule Endoscopy: General Principles and Current Applications , 2015, GE Portuguese journal of gastroenterology.

[11]  R. Pinho,et al.  Evaluation of the Usefulness of Virtual Chromoendoscopy with Different Color Modes in the MiroCam® System for Characterization of Small Bowel Lesions , 2018, GE - Portuguese Journal of Gastroenterology.

[12]  D. Faigel,et al.  A multicenter randomized comparison of the Endocapsule and the Pillcam SB. , 2008, Gastrointestinal endoscopy.

[13]  Jean-François Rey,et al.  Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists. , 2012, Clinics and research in hepatology and gastroenterology.

[14]  R. Pinho,et al.  Emergency single-balloon enteroscopy in overt obscure gastrointestinal bleeding: Efficacy and safety , 2014, United European gastroenterology journal.

[15]  R. Pinho,et al.  Evaluation and comparison of capsule endoscopy scores for assessment of inflammatory activity of small-bowel in Crohn's disease. , 2017, Gastroenterologia y hepatologia.

[16]  M. Lapalus,et al.  Can we shorten the small-bowel capsule reading time with the "Quick-view" image detection system? , 2012, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[17]  R. Pinho,et al.  Negative video capsule enteroscopy - what's the next step? , 2018, Gastroenterologia y hepatologia.

[18]  Validation of the computed assessment of cleansing score with the Mirocam® system. , 2016, Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva.

[19]  R. Pinho The Vanishing Frontiers of Therapeutic Enteroscopy , 2015, GE Portuguese journal of gastroenterology.

[20]  A. Riphaus,et al.  Capsule endoscopy interpretation by an endoscopy nurse - a comparative trial. , 2009, Zeitschrift fur Gastroenterologie.

[21]  J. Kjeldsen,et al.  High sensitivity of quick view capsule endoscopy for detection of small bowel Crohn's disease , 2014, Journal of gastroenterology and hepatology.

[22]  BarretoZuiga Rafael,et al.  Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small bowel disorders , 2015 .

[23]  H. Matsumoto,et al.  Evaluation of RAPID® 5 Access software for examination of capsule endoscopies and reading of the capsule by an endoscopy nurse , 2011, Journal of Gastroenterology.

[25]  R. Pinho,et al.  Diagnostic and therapeutic yields of urgent balloon-assisted enteroscopy in overt obscure gastrointestinal bleeding , 2018, European journal of gastroenterology & hepatology.

[26]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.

[27]  Hisao Tajiri,et al.  Evaluation of performance of the Omni mode for detecting video capsule endoscopy images: A multicenter randomized controlled trial , 2016, Endoscopy international open.

[28]  J. Rey,et al.  The use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy. , 2020, Gastrointestinal endoscopy.

[29]  E. Georgiou,et al.  Evaluation of four time-saving methods of reading capsule endoscopy videos , 2012, European journal of gastroenterology & hepatology.

[30]  Anastasios Koulaouzidis,et al.  QuickView in small-bowel capsule endoscopy is useful in certain clinical settings, but QuickView with Blue Mode is of no additional benefit , 2012, European journal of gastroenterology & hepatology.

[31]  P. Figueiredo,et al.  Multicenter survey on the use of device-assisted enteroscopy in Portugal , 2016, United European gastroenterology journal.