Biomechanical engineering analysis of commonly utilized mitral neochordae

[1]  Jung Hwa Bae,et al.  Development and Ex Vivo Validation of Novel Force-Sensing Neochordae for Measuring Chordae Tendineae Tension in the Mitral Valve Apparatus Using Optical Fibers With Embedded Bragg Gratings , 2019, Journal of biomechanical engineering.

[2]  P. Perier A New Paradigm for the Repair of Posterior Leaflet Prolapse: Respect Rather Than Resect , 2005 .

[3]  T. David Replacement of Chordae Tendineae with Expanded Polytetrafluoroethylene Sutures , 1989, Journal of cardiac surgery.

[4]  Revision of Commonly Used Loop Knots Efficiencies , 2020 .

[5]  Gaetano Burriesci,et al.  The neochord mitral valve repair procedure: Numerical simulation of different neochords tensioning protocols. , 2019, Medical engineering & physics.

[6]  R. Bauernschmitt,et al.  Chordal replacement versus quadrangular resection for repair of isolated posterior mitral leaflet prolapse. , 2010, The Annals of thoracic surgery.

[7]  M. Borger,et al.  Myxomatous Mitral Valve Repair: Loop Neochord Technique , 2015 .

[8]  D. Bates,et al.  Fitting Linear Mixed-Effects Models Using lme4 , 2014, 1406.5823.

[9]  David H. Adams,et al.  Current concepts in mitral valve repair for degenerative disease , 2006, Heart Failure Reviews.

[10]  Alberto Redaelli,et al.  Biomechanical drawbacks of different techniques of mitral neochordal implantation: When an apparently optimal repair can fail. , 2015, The Journal of thoracic and cardiovascular surgery.

[11]  F. Mohr,et al.  Chordal replacement for both minimally invasive and conventional mitral valve surgery using premeasured Gore-Tex loops. , 2000, The Annals of thoracic surgery.

[12]  M. Jensen,et al.  Transapical neochord implantation: is tension of artificial chordae tendineae dependent on the insertion site? , 2014, The Journal of thoracic and cardiovascular surgery.

[13]  Per B. Brockhoff,et al.  lmerTest Package: Tests in Linear Mixed Effects Models , 2017 .

[14]  C. Duran,et al.  Techniques for ensuring the correct length of new mitral chords. , 2003, The Journal of heart valve disease.

[15]  F. Mohr,et al.  Gore-Tex Loop Implantation for Mitral Valve Prolapse: The Leipzig Loop Technique , 2008 .

[16]  Volkmar Falk,et al.  Degenerative mitral valve regurgitation: best practice revolution , 2010, European heart journal.

[17]  J. Garbade,et al.  Loop neochord versus leaflet resection techniques for minimally invasive mitral valve repair: long-term results. , 2020, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.