Zeus thin solenoid: test results analysis
暂无分享,去创建一个
The thin solenoid for the Zeus detector has been installed and tested in HERA (Hadron Electron Ring Accelerator) at DESY. The coil reached the design magnetic field (1.8 T in the center) without training. During the test some measurements were made in order to investigate the cooling system and the quench-back behavior. No spontaneous quenches occurred. Several induced fast discharges showed the evidence of a quench-back effect, and the quench-back starting time was less than 1 s. The cylinder temperature measurements during the coil discharge perfectly agree with adiabatic calculations. The indirect cooling efficiency was verified for the two-layer winding. The tests performed showed that the magnet can operate safely at the nominal field.
[1] L. Rossi,et al. Thin and compensating solenoids for ZEUS detector , 1988 .
[2] R. Penco,et al. Zeus Magnet Tests , 1990 .
[3] R. Penco,et al. Zeus Magnets Construction Status Report , 1990 .