Vortex Analysis of Intra-Aneurismal Flow in Cerebral Aneurysms

This study aims to develop an alternative vortex analysis method by measuring structure ofIntracranial aneurysm (IA) flow vortexes across the cardiac cycle, to quantify temporal stability of aneurismal flow. Hemodynamics were modeled in “patient-specific” geometries, using computational fluid dynamics (CFD) simulations. Modified versions of known λ 2 and Q-criterion methods identified vortex regions; then regions were segmented out using the classical marching cube algorithm. Temporal stability was measured by the degree of vortex overlap (DVO) at each step of a cardiac cycle against a cycle-averaged vortex and by the change in number of cores over the cycle. No statistical differences exist in DVO or number of vortex cores between 5 terminal IAs and 5 sidewall IAs. No strong correlation exists between vortex core characteristics and geometric or hemodynamic characteristics of IAs. Statistical independence suggests this proposed method may provide novel IA information. However, threshold values used to determine the vortex core regions and resolution of velocity data influenced analysis outcomes and have to be addressed in future studies. In conclusions, preliminary results show that the proposed methodology may help give novel insight toward aneurismal flow characteristic and help in future risk assessment given more developments.

[1]  Jinhee Jeong,et al.  On the identification of a vortex , 1995, Journal of Fluid Mechanics.

[2]  Dinggang Shen,et al.  Machine Learning in Medical Imaging , 2012, Lecture Notes in Computer Science.

[3]  G E Karniadakis,et al.  Flow instability and wall shear stress variation in intracranial aneurysms , 2010, Journal of The Royal Society Interface.

[4]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[5]  C. Putman,et al.  Hemodynamics of Cerebral Aneurysms. , 2009, Annual review of fluid mechanics.

[6]  Jingfeng Jiang,et al.  Flow characteristics in a canine aneurysm model: a comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations. , 2011, Medical physics.

[7]  E. Wellnhofer,et al.  Intraaneurysmal flow: evaluation with Doppler guidewires. , 1996, AJNR. American journal of neuroradiology.

[8]  MING JIANG,et al.  Detection and Visualization of Vortices , 2005, The Visualization Handbook.

[9]  E. Connolly,et al.  Guidelines for the Management of Patients With Unruptured Intracranial Aneurysms: A Guideline for Healthcare Professionals From the American Heart Association/American Stroke Association , 2015, Stroke.

[10]  M. Markl,et al.  In vivo visualization and analysis of 3-D hemodynamics in cerebral aneurysms with flow-sensitized 4-D MR imaging at 3 T , 2008, Neuroradiology.

[11]  D. Holdsworth,et al.  Image-based computational simulation of flow dynamics in a giant intracranial aneurysm. , 2003, AJNR. American journal of neuroradiology.

[12]  J. Mocco,et al.  Hemodynamic–Morphologic Discriminants for Intracranial Aneurysm Rupture , 2011, Stroke.

[13]  J. Mocco,et al.  MORPHOLOGY PARAMETERS FOR INTRACRANIAL ANEURYSM RUPTURE RISK ASSESSMENT , 2008, Neurosurgery.

[14]  G. Haller An objective definition of a vortex , 2004, Journal of Fluid Mechanics.

[15]  Bongjae Chung,et al.  CFD for Evaluation and Treatment Planning of Aneurysms: Review of Proposed Clinical Uses and Their Challenges , 2014, Annals of Biomedical Engineering.

[16]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[17]  D. d'Humières,et al.  Multiple–relaxation–time lattice Boltzmann models in three dimensions , 2002, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[18]  David A. Steinman,et al.  A Framework for Geometric Analysis of Vascular Structures: Application to Cerebral Aneurysms , 2009, IEEE Transactions on Medical Imaging.

[19]  C Caroselli,et al.  Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms: A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association , 2000, Stroke.

[20]  A. Algra,et al.  Prevalence of unruptured intracranial aneurysms, with emphasis on sex, age, comorbidity, country, and time period: a systematic review and meta-analysis , 2011, The Lancet Neurology.

[21]  B. Weir Unruptured intracranial aneurysms: a review. , 2002, Journal of neurosurgery.

[22]  S. Amin-Hanjani,et al.  Regional Cerebral Blood Flow Using Quantitative MR Angiography , 2007, American Journal of Neuroradiology.

[23]  K. Gärtner,et al.  3D boundary recovery by constrained Delaunay tetrahedralization , 2011 .

[24]  Jingfeng Jiang,et al.  Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow , 2011, Physics in medicine and biology.

[25]  Jingfeng Jiang,et al.  Interactive Decomposition and Mapping of Saccular Cerebral Aneurysms Using Harmonic Functions: Its First Application With “Patient-Specific” Computational Fluid Dynamics (CFD) Simulations , 2013, IEEE Transactions on Medical Imaging.

[26]  P. Moin,et al.  Eddies, streams, and convergence zones in turbulent flows , 1988 .

[27]  D. Ku,et al.  Pulsatile flow in the human left coronary artery bifurcation: average conditions. , 1996, Journal of biomechanical engineering.

[28]  David A. Steinman,et al.  Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries , 2002, Annals of Biomedical Engineering.

[29]  H. P. Lee,et al.  PROPER ORTHOGONAL DECOMPOSITION AND ITS APPLICATIONS—PART I: THEORY , 2002 .

[30]  F. Mut,et al.  Association of Hemodynamic Characteristics and Cerebral Aneurysm Rupture , 2011, American Journal of Neuroradiology.

[31]  Christof Karmonik,et al.  Aneurysm Volume-to-Ostium Area Ratio: A Parameter Useful for Discriminating the Rupture Status of Intracranial Aneurysms , 2011, Neurosurgery.

[32]  D. Wiebers,et al.  Cerebral aneurysms. , 2006, The New England journal of medicine.

[33]  Bernhard Preim,et al.  Semi-Automatic Vortex Extraction in 4D PC-MRI Cardiac Blood Flow Data using Line Predicates , 2013, IEEE Transactions on Visualization and Computer Graphics.

[34]  Weeratunge Malalasekera,et al.  An introduction to computational fluid dynamics - the finite volume method , 2007 .

[35]  N. Pelc,et al.  Blood flow in major cerebral arteries measured by phase-contrast cine MR. , 1994, AJNR. American journal of neuroradiology.

[36]  C. Petz,et al.  Cerebral Aneurysm Hemodynamics and a Length of Parent Vessel , 2009 .

[37]  F Mut,et al.  Quantifying the Large-Scale Hemodynamics of Intracranial Aneurysms , 2014, American Journal of Neuroradiology.

[38]  Nigel Hoggard,et al.  MR Derived Volumetric Flow Rate Waveforms at Locations within the Common Carotid, Internal Carotid, and Basilar Arteries , 2009, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[39]  Michael Forsting,et al.  European Stroke Organization Guidelines for the Management of Intracranial Aneurysms and Subarachnoid Haemorrhage , 2013, Cerebrovascular Diseases.