Imaging Capabilities of the Inveon SPECT System Using Single-and Multipinhole Collimators
暂无分享,去创建一个
Frederic Boisson | David Zahra | Anthonin Reilhac | Marie-Claude Gregoire | Arvind Parmar | Steven R Meikle | Hasar Hamse | M. Grégoire | S. Meikle | A. Reilhac | F. Boisson | A. Parmar | D. Zahra | Hasar Hamse
[1] T D Cradduck,et al. National electrical manufacturers association , 1983, Journal of the A.I.E.E..
[2] Roberto Accorsi,et al. Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging—a simulation study , 2005, Physics in medicine and biology.
[3] P. Acton,et al. Small-Animal SPECT and SPECT/CT: Important Tools for Preclinical Investigation* , 2008, Journal of Nuclear Medicine.
[4] F. Beekman,et al. U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging , 2009, Journal of Nuclear Medicine.
[5] N. Schramm,et al. High-resolution SPECT using multi-pinhole collimation , 2002, IEEE Nuclear Science Symposium Conference Record.
[6] Cornelis H Slump,et al. Using the NEMA NU 4 PET Image Quality Phantom in Multipinhole Small-Animal SPECT , 2011, The Journal of Nuclear Medicine.
[7] Stefan Eberl,et al. A prototype coded aperture detector for small animal SPECT , 2001 .
[8] J. Disselhorst,et al. Image quality phantom and parameters for high spatial resolution small-animal SPECT , 2011 .
[9] K Hamamoto,et al. [Scintillation camera]. , 1967, Saishin igaku. Modern medicine.
[10] Freek J Beekman,et al. The effects of object activity distribution on multiplexing multi-pinhole SPECT. , 2011, Physics in medicine and biology.
[11] B. Hutton,et al. The potential for mixed multiplexed and non-multiplexed data to improve the reconstruction quality of a multi-slit–slat collimator SPECT system , 2010, Physics in medicine and biology.
[12] D. Weber,et al. Ultra-high-resolution imaging of small animals: Implications for preclinical and research studies , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[13] S R Meikle,et al. An investigation of inconsistent projections and artefacts in multi-pinhole SPECT with axially aligned pinholes. , 2011, Physics in medicine and biology.
[14] R. Kramer,et al. Functional imaging of multidrug-resistant P-glycoprotein with an organotechnetium complex. , 1993, Cancer research.
[15] P. V. van Rijk,et al. U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[16] Brendan Vastenhouw,et al. VECTor: A Preclinical Imaging System for Simultaneous Submillimeter SPECT and PET , 2013, The Journal of Nuclear Medicine.
[17] F. Difilippo. Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT–CT scanners , 2008, Physics in medicine and biology.
[18] Kathleen Vunckx,et al. Single and Multipinhole Collimator Design Evaluation Method for Small Animal SPECT , 2008, IEEE Transactions on Medical Imaging.
[19] M. Defrise,et al. Three-pinhole collimator to improve axial spatial resolution and sensitivity in pinhole SPECT , 2007, European Journal of Nuclear Medicine and Molecular Imaging.
[20] Keiichi Magota,et al. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging , 2011, European Journal of Nuclear Medicine and Molecular Imaging.
[21] R. Holen,et al. Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging , 2013, European Journal of Nuclear Medicine and Molecular Imaging.
[22] J. Hoppin,et al. Improving resolution, sensitivity and applications for the NanoSPECT/CT: A high-performance SPECT/CT imager for small-animal research , 2007 .