Resonant ultrasonic wireless power transmission for bio-implants

In this paper, we present the ultrasonic wireless power transmission system as part of a brain-machine interface (BMI) system in development to supply the required electric power. Making a small-size implantable BMI, it is essential to design a low power unit with a rechargeable battery. The ultrasonic power transmission system has two piezoelectric transducers, facing each other between skin tissues converting electrical energy to mechanical vibrational energy or vice versa. Ultrasound is free from the electromagnetic coupling effect and medical frequency band limitations which making it a promising candidate for implantable purposes. In this paper, we present the design of piezoelectric composite transducer, the rectifier circuit, and rechargeable battery that all packaged in biocompatible titanium can. An initial prototype device was built for demonstration purpose. The early experimental results demonstrate the prototype device can reach 50% of energy transmission efficiency in a water medium at 20mm distance and 18% in animal skin tissue at 18mm distance, respectively.

[1]  J. Millán,et al.  Detection of self-paced reaching movement intention from EEG signals , 2012, Front. Neuroeng..

[2]  G. Pfurtscheller,et al.  Brain-Computer Interfaces for Communication and Control. , 2011, Communications of the ACM.

[3]  F Cincotti,et al.  Current trends in hardware and software for brain–computer interfaces (BCIs) , 2011, Journal of neural engineering.

[4]  Piotr J. Durka,et al.  User-centered design of brain-computer interfaces: OpenBCI.pl and BCI Appliance , 2012 .

[5]  Gary Garcia-Molina,et al.  Phase Detection of Visual Evoked Potentials Applied to Brain Computer Interfacing , 2012 .

[6]  Günter Edlinger,et al.  The First Commercial Brain–Computer Interface Environment , 2009 .

[7]  B. Towe,et al.  Miniature ultrasonically powered wireless nerve cuff stimulator , 2011, 2011 5th International IEEE/EMBS Conference on Neural Engineering.

[8]  J-Y Tsai,et al.  Ultrasonic wireless power and data communication for neural stimulation , 2011, 2011 IEEE International Ultrasonics Symposium.

[9]  José del R. Millán,et al.  Introduction to Devices, Applications and Users: Towards Practical BCIs Based on Shared Control Techniques , 2012 .

[10]  Babak Ziaie,et al.  An Ultrasonically Powered Implantable Micro-Oxygen Generator (IMOG) , 2011, IEEE Transactions on Biomedical Engineering.

[11]  Doron Shmilovitz,et al.  Ultrasonic transcutaneous energy transfer using a continuous wave 650 kHz Gaussian shaded transmitter. , 2010, Ultrasonics.

[12]  Jose L Pons,et al.  Monitoring Activities with Lower-Limb Exoskeletons , 2012 .

[13]  Roderick Murray-Smith,et al.  Designing Future BCIs: Beyond the Bit Rate , 2012 .

[14]  M. Duvinage,et al.  A five-state P300-based foot lifter orthosis: Proof of concept , 2012, 2012 ISSNIP Biosignals and Biorobotics Conference: Biosignals and Robotics for Better and Safer Living (BRC).

[15]  Arto Nurmikko,et al.  An implantable wireless neural interface for recording cortical circuit dynamics in moving primates , 2013, Journal of neural engineering.

[16]  Jose L Pons,et al.  Human-robot interfaces in exoskeletons for gait training after stroke: State of the art and challenges , 2012, HRI 2012.

[17]  W.R. Patterson,et al.  Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[18]  Herman van der Kooij,et al.  Model predictive control-based gait pattern generation for wearable exoskeletons , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[19]  Silvestro Micera,et al.  MUNDUS project: MUltimodal Neuroprosthesis for daily Upper limb Support , 2013, Journal of NeuroEngineering and Rehabilitation.

[20]  D. Farina,et al.  Bioinformatic Approaches Used in Modelling Human Tremor , 2009 .

[21]  S. Ozeri,et al.  Ultrasonic transcutaneous energy transfer for powering implanted devices. , 2010, Ultrasonics.