Optimal Placement and Sizing of SVC for Voltage Security Enhancement

In present day restructured power systems, increased transactions often lead to the situations where the system no longer remains in secure operating condition. To overcome such undesirable situation the Flexible AC transmission system (FACTS) controllers can be placed in a power system, which are able to provide fast and flexible control of voltage magnitude, active and reactive powers and to improve voltage security and stability. As investment cost of FACTS controllers is very high, these devices must be placed optimally in a power system. Static Var Compensators (SVC) is a shunt FACTS device that can be used for improvement of voltage profile in a power system. For optimal placement of SVC, this paper proposes a method that considers single line outage contingencies. On the basis of Voltage Performance Index two most critical contingencies are considered for searching the optimal location of SVC. The impact of SVC at selected optimal locations is evaluated and compared for varying load condition of the power system. The criteria for selection of optimal location consider improvement of the voltage profile and reduction in the system losses in a power system. The effectiveness of the proposed method is demonstrated on a standard IEEE 30-bus system.

[1]  Rachid Cherkaoui,et al.  Optimal location of FACTS devices to enhance power system security , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[2]  M.M. El Metwally,et al.  Optimal allocation of FACTS devices in power system using genetic algorithms , 2008, 2008 12th International Middle-East Power System Conference.

[3]  Abdelaziz Laifa,et al.  Optimal Location of SVC for Voltage Security Enhancement using MOPSO , 2009 .

[4]  Enrique Acha,et al.  FACTS: Modelling and Simulation in Power Networks , 2004 .

[5]  N. Mithulananthan,et al.  Comparison of Shunt Capacitor, SVC and STATCOM in Static Voltage Stability Margin Enhancement , 2004 .

[6]  Hadi Saadat,et al.  Power System Analysis , 1998 .

[7]  S. Gerbex,et al.  Optimal Location of Multi-Type FACTS Devices in a Power System by Means of Genetic Algorithms , 2001, IEEE Power Engineering Review.

[8]  S.N. Singh,et al.  An Approach for Optimal Placement of Static VAr Compensators Based on Reactive Power Spot Price , 2007, IEEE Transactions on Power Systems.

[9]  Allen J. Wood,et al.  Power Generation, Operation, and Control , 1984 .

[10]  Seema Singh,et al.  An Approach for Optimal Placement of Static VAr Compensators Based on Reactive Power Spot Price , 2007 .

[11]  C. Fuerte-Esquivel,et al.  Advanced SVC models for Newton-Raphson load flow and Newton optimal power flow studies , 2000 .

[12]  A.J. Conejo,et al.  Optimal Network Placement of SVC Devices , 2007, IEEE Transactions on Power Systems.

[13]  Timothy J. E. Miller,et al.  Reactive Power Control In Electric Systems , 1982 .