An Energy-Based Method for Predicting the Additive Effect of Multiple Film Cooling Rows

There have been numerous studies reporting film effectiveness for film rows in isolation, which have led to correlations which are used for preliminary design. Many applications require multiple film cooling rows. Although there is some published data which deals with the combined effect of multiple rows, in most design situations the additive effect is computed using correlations for single rows. The most widely used method is the Sellers superposition method. In many applications the method gives accurate results. Although the method is to some extent physically based, energy is not conserved within the model, and in certain situations this limitation can be shown to lead to an under-prediction of the film effectiveness.In this paper, a new energy-based method for predicting the additive effect of multiple film cooling rows is outlined. The physical basis and limitations of the model are discussed. Predictions conducted using the new method are compared with CFD data and contrasted with the Sellers method. In situations where energy conservation is required to avoid under-prediction of effectiveness the method is shown to be advantageous.Copyright © 2013 by Rolls-Royce plc

[1]  Christian Saumweber,et al.  Interaction of film cooling rows: Effects of hole geometry and row spacing on the cooling performance downstream of the second row of holes , 2004 .

[2]  M. Sasaki,et al.  Film Cooling Effectiveness for Injection from Multirow Holes , 1979 .

[3]  David G. Bogard,et al.  Evaluation of Pressure Side Film Cooling With Flow and Thermal Field Measurements—Part I: Showerhead Effects , 2002 .

[4]  F. J. Camarata,et al.  Multihole Cooling Film Effectiveness and Heat Transfer , 1974 .

[5]  J. H. Chin,et al.  Film Cooling With Multiple Slots and Louvers , 1961 .

[6]  Li He,et al.  Validation of the Immersed Mesh Block (IMB) Approach Against a Cooled Transonic Turbine Stage , 2012 .

[7]  M. Suo,et al.  The Additive Nature of Film Cooling From Rows of Holes , 1976 .

[8]  Achmed Schulz,et al.  Correlation of Film-Cooling Effectiveness From Thermographic Measurements at Enginelike Conditions , 2002 .

[9]  Achmed Schulz,et al.  Interactions of Film Cooling Rows: Effects of Hole Geometry and Row Spacing on the Cooling Performance Downstream of the Second Row of Holes , 2003 .

[10]  D. Lampard,et al.  The Film Cooling Effectiveness of Double Rows of Holes , 1979 .

[11]  David G. Bogard,et al.  Effects of Showerhead Injection on Film Cooling Effectiveness for a Downstream Row of Holes , 2000 .

[12]  Hossein Nadali Najafabadi,et al.  Comparison of Gas Turbine Vane Pressure Side and Suction Side Film Cooling Performance and the Applicability of Superposition , 2012 .

[13]  S. Aoki,et al.  Film Cooling on a Gas Turbine Rotor Blade , 1991 .

[14]  Huiren Zhu,et al.  Investigation of film cooling and superposition method for double row dustpan-shaped holes , 2008 .

[15]  Jens von Wolfersdorf,et al.  Effect of Showerhead Injection on Superposition of Multi-Row Pressure Side Film Cooling With Fan Shaped Holes , 2003 .

[16]  Antonio Andreini,et al.  Film Cooling System Numerical Design: Adiabatic and Conjugate Analysis , 2005 .

[17]  Je-Chin Han,et al.  Effect of Superposition on Spanwise Film-Cooling Effectiveness Distribution on a Gas Turbine Blade , 2006 .

[18]  J. Sellers Gaseous Film Cooling with Multiple Injection Stations , 1963 .

[19]  Karen A. Thole,et al.  Full-Coverage Film Cooling With Short Normal Injection Holes , 2001 .