Design and deployment of a portable membrane equilibrator for sampling aqueous dissolved gases

We present designs for a portable trace gas sampler, based on membrane technology, to obtain a gas sample from water in the field. A continuous flow of water is equilibrated with a finite volume of gas until the gas pressure matches the total dissolved gas pressure of the water stream. Samples collected in this manner can be analyzed to determine original water concentrations for potentially any dissolved gas. The sampler requires neither compressed carrier gas nor a vacuum pump to extract the dissolved gas sample; its power consumption is minimal and it fits within a 30 L plastic case. During the development stages, both major atmospheric gases (N2, O2, and Ar) and trace gases (CO2, SF6, and SF5CF3) were measured to confirm the equilibrium condition and to quantify the response time. Equilibration studies were conducted in the laboratory and at the site of a borehole CO2 injection experiment on the Lamont campus of Columbia University. The time required to achieve solubility equilibrium depends on the dissolved gas content and the water flow rate; we determined an e‐folding response time of 9–12 min, under air‐saturated conditions and with a flow rate of 2 L/min. Typically, equilibrium is achieved within 30–45 min. We compare the system function and analytical results to conventional sampling methods during the recovery phase of a push‐pull experiment and find a generally good agreement within 10% of conventional analyses for each of the gases.

[1]  L. N. Plummer,et al.  Evidence for terrigenic SF6 in groundwater from basaltic aquifers, Jeju island, Korea: Implications for groundwater dating , 2007 .

[2]  Martin Stute,et al.  Contact zone permeability at intrusion boundaries: new results from hydraulic testing and geophysical logging in the Newark Rift Basin, New York, USA , 2006 .

[3]  Taro Takahashi,et al.  High‐frequency measurement of partial pressure and total concentration of carbon dioxide in seawater using microporous hydrophobic membrane contactors , 2004 .

[4]  Brian Ward,et al.  Influence of rain on air-sea gas exchange: Lessons from a model ocean , 2004 .

[5]  Peter Schlosser,et al.  Determination of longitudinal dispersion coefficient and net advection in the tidal hudson river with a large-scale, high resolution SF6 tracer release experiment. , 2002, Environmental Science and Technology.

[6]  G. Bönisch,et al.  Renewal and circulation of intermediate waters in the Canadian Basin observed on the SCICEX 96 cruise , 2000 .

[7]  Imona C. Omole Hollow-fiber membrane contactors , 1999 .

[8]  J. Istok,et al.  Single‐Well, “Push‐Pull” Test for In Situ Determination of Microbial Activities , 1997 .

[9]  R. Wanninkhof,et al.  The effect of rain on air-water gas exchange , 1997 .

[10]  D. Solomon,et al.  Dissolved gas tracers in groundwater: Simplified injection, sampling, and analysis , 1996 .

[11]  Geert Versteeg,et al.  Microporous hollow fibre membrane modules as gas-liquid contactors. Part 1: Physical mass transfer processes. A specific application: mass transfer in highly viscous liquids , 1993 .

[12]  W. Broecker,et al.  Gas exchange on Mono Lake and Crowley Lake, California , 1987 .

[13]  R. Weiss Carbon dioxide in water and seawater: the solubility of a non-ideal gas , 1974 .

[14]  R. Weiss Solubility of helium and neon in water and seawater , 1971 .