A gamma and neutron phoswich read out with SiPM for SPRD
暂无分享,去创建一个
Cenxi Yuan | Qibin Fu | Tuchen Huang | C. Yuan | Tuchen Huang | Qibin Fu | Shaopeng Lin | Shaopeng Lin
[1] Benjamin S. McDonald,et al. A wearable sensor based on CLYC scintillators , 2016 .
[2] D. Ramsden,et al. A compact neutron detector based on the use of a SiPM detector , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.
[3] Characterization of 4×4ch MPPC array in scintillation spectrometry , 2013, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).
[4] A. Alhawsawi,et al. A compton-suppressed phoswich detector for gamma spectroscopy , 2013, Journal of Radioanalytical and Nuclear Chemistry.
[5] Kanai S. Shah,et al. Development of Cs2LiYCl6 scintillator , 2013 .
[6] M. Grodzicka-Kobylka,et al. Comparison of SensL and Hamamatsu 4×4 channel SiPM arrays in gamma spectrometry with scintillators , 2017 .
[7] Nicholas Dallmann,et al. A Cs 2 LiYCl 6 :Ce-based advanced radiation monitoring device , 2015 .
[8] S. Pozzi,et al. Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers , 2015 .
[10] M. Nakhostin. Recursive algorithms for digital implementation of neutron/gamma discrimination in liquid scintillation detectors , 2012 .
[11] M. Zuffa,et al. Comparison between a silicon PIN diode and a CsI(Tl) coupled to a silicon PIN diode for dosimetric purpose in radiology , 2014 .
[12] M. Moszynski,et al. Energy resolution of small scintillation detectors with SiPM light readout , 2013 .
[13] H. Ishibashi,et al. Development of a three-layer phoswich alpha–beta–gamma imaging detector , 2015 .
[14] Yanguo Li,et al. A novel analog power supply for gain control of the Multi-Pixel Photon Counter (MPPC) , 2016, 1606.03727.
[15] M. Moszynski,et al. /sup 6/LiI(Eu) in neutron and /spl gamma/-ray spectrometry-a highly sensitive thermal neutron detector , 2005, IEEE Transactions on Nuclear Science.
[16] Rhys M. Preston,et al. Neutron-Gamma Pulse Shape Discrimination Using Organic Scintillators With Silicon Photomultiplier Readout , 2014, IEEE Transactions on Nuclear Science.
[17] Biao Wang,et al. NaI(Tl) scintillator read out with SiPM array for gamma spectrometer , 2017 .
[18] F. Licciulli,et al. A Novel Technique for the Stabilization of SiPM Gain Against Temperature Variations , 2013, IEEE Transactions on Nuclear Science.
[19] G. Nebbia,et al. A novel detector assembly for detecting thermal neutrons, fast neutrons and gamma rays , 2016 .
[20] A. Alhawsawi,et al. Real-time pulse-shape discrimination and beta-gamma coincidence detection in field-programmable gate array , 2013 .
[21] General purpose pulse shape analysis for fast scintillators implemented in digital readout electronics , 2016 .
[22] M. Moszynski,et al. Characterization of large TSV MPPC arrays (4×4ch and 8×8 ch) in scintillation spectrometry , 2017 .