Capacitive immunosensor for the detection of host cell proteins.

A new analysis for monitoring host cell proteins in preparations of transgenically produced protein pharmaceuticals is described. A capacitive biosensor with a very high sensitivity is used to monitor trace amounts of host cell proteins. The sensor consists of a gold electrode, the surface of which is well insulated and on which a preparation of a population of polyclonal antibodies raised against the complete protein set-up of the host cell are immobilized. Host cell proteins are present at very low concentrations during the production of a transgenic protein. The system studied here is a model system with an enzyme expressed in Escherichia coli (E. coli). Due to the high sensitivity, it may even be possible to dilute the samples to be analyzed, thereby reducing a negative influence from non-specific binding to the sensor surface.

[1]  DiPaolo,et al.  Monitoring impurities in biopharmaceuticals produced by recombinant technology. , 1999, Pharmaceutical science & technology today.

[2]  George G. Guilbault,et al.  Recommendations for Nomenclature of Ion-selective Electrodes , 1977 .

[3]  B. Mattiasson Immunochemical assays for process control: potentials and limitations , 1984 .

[4]  P. Kanatharana,et al.  Detecting penicillin G in milk with impedimetric label-free immunosensor. , 2007, Biosensors & bioelectronics.

[5]  G. Johansson,et al.  An immunological interleukine-6 capacitive biosensor using perturbation with a potentiostatic step. , 1998, Biosensors & bioelectronics.

[6]  Bo Mattiasson,et al.  Continuous measurements of a binding reaction using a capacitive biosensor. , 2005, Biosensors & bioelectronics.

[7]  B. Mattiasson,et al.  Thermometric enzyme linked immunosorbent assay in continuous flow system: optimization and evaluation using human serum albumin as a model system. , 1978, Clinica chimica acta; international journal of clinical chemistry.

[8]  Michael Rubacha,et al.  Demonstration of Robust Host Cell Protein Clearance in Biopharmaceutical Downstream Processes , 2008, Biotechnology progress.

[9]  Richard P. Buck,et al.  Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994) , 1994 .

[10]  Bo Mattiasson,et al.  A comparative study of capacitive immunosensors based on self-assembled monolayers formed from thiourea, thioctic acid, and 3-mercaptopropionic acid. , 2006, Biosensors & bioelectronics.

[11]  P. Dephillips,et al.  Identification of an Escherichia coli Protein Impurity in Preparations of a Recombinant Pharmaceutical , 1993, Pharmaceutical Research.

[12]  G. Johansson,et al.  Capacitance measurements of antibody-antigen interactions in a flow system. , 1997, Analytical chemistry.

[13]  V Anicetti,et al.  Analytical considerations in the development of protein purification processes. , 1994, Bioprocess technology.