Retentive Force of the Konus Telescope on One-piece Implant

The objective of this study was to evaluate the retentive force of one-piece implant (Nobel Direct; Nobel Biocare, Sweden) -supported overdentures including a telescope system. The regular platform Nobel Direct (4.3 mm dia.) was embedded in a brass patrix frame (10 x 10 x 25 mm) using autopolymerized polymethyl methacrylate (PMMA; Unifast II, GC). Two sizes of O-rings [O1 (2.8 mm dia.) and O2 (3.8 mm dia.), SAN-EI, Japan] and protection caps (PC; Straumann) were placed on the Nobel Direct abutment head. The plastic patterns of the Konus telescope outer crown were fabricated on the Nobel Direct abutment head and cast using the GC autocast system. As a control, the PMMA resin (RE) was made to directly touch the abutment head. The patrix and matrix frames were connected under 2 kg and then mounted on a screw-driven mechanical testing machine (Model UTM II, Toyo Boldwin, Japan). The retentive force (n=5, N) obtained at a crosshead speed of 40 mm⁄min was analyzed by ANOVA⁄Scheffe's test (α=0.05). The larger O-ring had less retentive force than the smaller O-ring. The Konus telescope had a retentive force comparable to that of the smaller O-ring (p>0.05). Although the retentive forces of the Konus telescope tended to increase as the connecting load increased, the force of the O-ring did not vary according to the connecting loads. For the one implant-supported overdentures, not only a medium-sized O-ring and protection cap but also coping and Konus telescopes demonstrated having appropriate retentive force.

[1]  I. Watanabe,et al.  Dimensional change of laser-welded gold alloy induced by heat treatment. , 2007, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[2]  Yasunori Suzuki,et al.  Retentive force of O-ring attachment to use Immediate Provisional Implant (IPI)-retained overdenture. , 2005, The European journal of prosthodontics and restorative dentistry.

[3]  S. Parel,et al.  Early clinical experience with a new one-piece implant system in single tooth sites. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[4]  J. Hahn One-piece root-form implants: a return to simplicity. , 2005, The Journal of oral implantology.

[5]  Yasunori Suzuki,et al.  Titanium removable partial denture clasp repair using laser welding: a clinical report. , 2004, The Journal of prosthetic dentistry.

[6]  C. Ohkubo,et al.  O-ring attachments for transitional implant-retained overdentures. , 2004, The Journal of prosthetic dentistry.

[7]  Chikahiro Ohkubo,et al.  In vitro wear assessment of titanium alloy teeth. , 2002, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[8]  K. Yanagisawa,et al.  A Measurement of Galvanic Current and Electrical Potential in Extracted Human Teeth , 1986, Journal of dental research.

[9]  Mariko Kobayashi Comparing the Retentive Force of O-ring and Several Retained Systems for One-piece Root-form Implant-retained Overdentures , 2006 .