Twelfth thoracic-first lumbar vertebral mechanical stability of fractures after Harrington-rod instrumentation.

UNLABELLED Thirteen fresh cadaver spinal segments (fifth thoracic to fifth lumbar vertebra) with a posterior ligamentous defect at the twelfth thoracic-first lumbar level were tested to failure in flexion, creating an unstable fracture at the twelfth thoracic and first lumbar vertebrae. The fractured spines were then instrumented with Harrington distraction rods and retested. Spines instrumented at the eleventh thoracic to second lumbar vertebrae were not significantly stronger than uninstrumented specimens (with a posterior ligamentous defect). Repositioning the upper hook from the eleventh to the tenth thoracic vertebra increased the failure moment by an average of 36 per cent. Instrumentation of the spine at either level protected the spinal column against distraction at the fracture site until a threshold movement was reached. Moving the upper hook from the eleventh up to the tenth thoracic vertebra increased the threshold moment by an average of 65 per cent. Our recommended hook placement at the tenth thoracic and second lumbar vertebrae tends to reduce tilting of the upper vertebra, changing the mode of failure from slip-out of the upper hook (with partial laminar fracture) to total laminar fracture. CLINICAL RELEVANCE The presence of internal fixation rods in itself does not make the unstable fractured spine stronger in a flexion mode. The level of hook placement above and below the fracture is important in determining with bending strength of the instrumented spine. When the use of Harrington distraction rods is contemplated for internally stabilizing a fractured spine, a specific level of hook placement, three laminae above and two laminae below the point of instability, is recommended. This configuration allows the instrumentation to maintain increased spinal stability in a flexion mode by reducing the tendency for the upper hooks to "back out" and lose their hold secondary to vertebral tilting.

[1]  H. Kaufer,et al.  Patterns and mechanisms of lumbar injuries associated with lap seat belts. , 1969, The Journal of bone and joint surgery. American volume.

[2]  G. Wharton Stabilization of spinal injuries for early mobilization. , 1978, The Orthopedic clinics of North America.

[3]  T. Whitesides Traumatic Kyphosis of the Thoracolumbar Spine , 1977, Clinical orthopaedics and related research.

[4]  F. Convery,et al.  Fracture-Dislocation of the Dorsal-Lumbar Spine: Acute Operative Stabilization By Harrington Instrumentation , 1978, Spine.

[5]  D O Hancock,et al.  The value of postural reduction in the initial management of closed injuries of the spine with paraplegia and tetraplegia , 1969, Paraplegia.

[6]  G. Wharton,et al.  The results of laminectomy in patients with incomplete spinal cord injuries , 1971, Paraplegia.

[7]  A. White,et al.  The Clinical Biomechanics of Kyphotic Deformities , 1977, Clinical orthopaedics and related research.

[8]  P. R. Harrington,et al.  Results of reduction and stabilization of the severely fractured thoracic and lumbar spine. , 1978, The Journal of bone and joint surgery. American volume.

[9]  A. Katznelson Stabilisation of the spine in traumatic paraplegia , 1969, Paraplegia.

[10]  G. Bedbrook Recent advances in the management of spinal injuries with paralysis. , 1977, The Australian and New Zealand journal of surgery.

[11]  D. Burke,et al.  The management of thoracic and thoraco-lumbar injuries of the spine with neurological involvement. , 1976, The Journal of bone and joint surgery. British volume.

[12]  M. Makin,et al.  Open reduction of unstable thoracolumbar spinal injuries and fixation with Harrington rods. , 1977, The Journal of bone and joint surgery. American volume.