Installation and operation of FACTS devices for enhancing steady-state security

Abstract This paper presents principles about installation and operation of flexible ac transmission systems (FACTS) devices to enhance the steady-state security of power system. Three generic types of FACTS devices are introduced and the proper location of each kind of FACTS devices is determined in accordance with the individual purpose of use. It is desirable to install shunt controllers where there is a need for voltage support according to V – Q sensitivity analysis and to install series controllers where line flow control is required to increase system loadability. It is also important to install combined series–shunt controllers such as UPFC in order to get most of their merits, that is, to control both the active and reactive power flow. An algorithm to minimize simultaneously and iteratively both kinds of security indices such as J P relating to line flow and J V relating to bus voltage is proposed in this paper. For minimization of security indices, each sensitivity vector of both indices is derived analytically. Results from the minimization show that optimal operating points of FACTS devices under various conditions of power system have been achieved. The proposed methodology to install and operate FACTS devices properly is verified on the IEEE 57-bus system where FACTS devices were operated under normal condition and in a line-faulted contingency.

[1]  S. Massucco,et al.  Management of interruptible loads for power system security and operation , 2002, IEEE Power Engineering Society Summer Meeting,.

[2]  Mehrdad Ghandhari,et al.  Improving power system dynamics by series-connected FACTS devices , 1997 .

[3]  A.P.S. Meliopoulos,et al.  Power system small signal stability analysis with FACTS elements , 1997 .

[4]  Seema Singh Location of FACTS devices for enhancing power systems' security , 2001, LESCOPE 01. 2001 Large Engineering Systems Conference on Power Engineering. Conference Proceedings. Theme: Powering Beyond 2001 (Cat. No.01ex490).

[5]  R. H. Lasseter,et al.  Re-dispatching generation to increase power system security margin and support low voltage bus , 2000 .

[6]  J. A. Momoh,et al.  Power System Security Enhancement by OPF with Phase Shifter , 2001, IEEE Power Engineering Review.

[7]  R. Cherkaoui,et al.  Enhancement of power system transient stability using superconducting fault current limiters , 1999, IEEE Transactions on Applied Superconductivity.

[8]  B. Gao,et al.  Voltage Stability Evaluation Using Modal Analysis , 1992, IEEE Power Engineering Review.

[9]  Allen J. Wood,et al.  Power Generation, Operation, and Control , 1984 .

[10]  F. Jurado,et al.  Optimal location of SVC based on system loadability and contingency analysis , 1999, 1999 7th IEEE International Conference on Emerging Technologies and Factory Automation. Proceedings ETFA '99 (Cat. No.99TH8467).

[11]  S.I. Moon,et al.  An operation scheme of UPFC's considering operating objectives and states , 2002, IEEE Power Engineering Society Summer Meeting,.

[12]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[13]  G. T. Heydt,et al.  Power flow control and power flow studies for systems with FACTS devices , 1998 .

[14]  Atif S. Debs,et al.  Modern power systems control and operation , 1988 .

[15]  S. Jalali,et al.  Determination of location and amount of series compensation to increase power transfer capability , 1998 .