Isolated left ventricular assist as bridge to cardiac transplantation.

The electrically driven Novacor implantable left ventricular assist device has been implanted in six patients (four men and two women) since Sept. 7, 1984. In four of the six patients (67%) the device was a successful bridge to cardiac transplantation. One patient died of multiple organ failure and Candida sepsis after 16 days of support with the device. One patient died in the operating room of uncontrollable hemorrhage and biventricular failure caused by severe cardiac rejection. Three patients are alive with cardiac transplants 38, 17, and 10 months after transplantation. One patient died after cardiac transplantation of presumed sepsis. The Novacor left ventricular assist device performed in all cases without mechanical or electrical failure. Excluding the intraoperative death, assist duration ranged from 2 to 16 days. The cardiac index (synonymous with device output) ranged from 2.4 to 3.4 L/min/m2. No embolic events (cerebrovascular or systemic) occurred during assistance with the device. Minimal red cell hemolysis was documented during the period of support. The Novacor left ventricular assist device is a safe and effective bridge to cardiac transplantation in patients with refractory cardiogenic shock.

[1]  E. Hammond,et al.  Clinical use of the total artificial heart. , 1984, The New England journal of medicine.

[2]  J. F. Keane,et al.  Clinical and hemodynamic results of the Fontan operation for tricuspid atresia. , 1982, The American journal of cardiology.

[3]  P J Miller,et al.  Evolution of the solenoid-actuated left ventricular assist system: integration with a pusher-plate pump for intra-abdominal implantation in the calf. , 1978, Artificial organs.

[4]  S. Gidding,et al.  Fontan type operation for complex lesions. Surgical considerations to improve survival. , 1986, The Journal of thoracic and cardiovascular surgery.

[5]  M. Buckley,et al.  Prostaglandin E1. A new therapy for refractory right heart failure and pulmonary hypertension after mitral valve replacement. , 1985, The Journal of thoracic and cardiovascular surgery.

[6]  Denton A. Cooley,et al.  Total artificial heart in two-staged cardiac transplantation. , 1981, Cardiovascular diseases.

[7]  E. Stinson,et al.  Development of a totally implantable, electrically actuated left ventricular assist system. , 1980, American journal of surgery.

[8]  W S Pierce,et al.  Mechanical support of the circulation followed by cardiac transplantation. , 1986, The Journal of thoracic and cardiovascular surgery.

[9]  W. Pae,et al.  Ventricular-assist pumping in patients with cardiogenic shock after cardiac operations. , 1981, The New England journal of medicine.

[10]  N. Shumway,et al.  Studies on orthotopic homotransplantation of the canine heart. , 1960, Surgical forum.

[11]  B. Griffith,et al.  Summary of the world experience with clinical use of total artificial hearts as heart support devices. , 1986, The Journal of heart transplantation.

[12]  Jal S. Jassawalla,et al.  A Totally Implantable Ventricular Assist Device for End-Stage Heart Disease , 1984 .

[13]  C. Hall,et al.  PROLONGED ASSISTED CIRCULATION DURING AND AFTER CARDIAC OR AORTIC SURGERY. PROLONGED PARTIAL LEFT VENTRICULAR BYPASS BY MEANS OF INTRACORPOREAL CIRCULATION. , 1963, The American journal of cardiology.

[14]  J. Copeland,et al.  Thromboembolic complications of the Jarvik-7 total artificial heart: case report. , 1986, Artificial organs.

[15]  V. Behar,et al.  Clinical implications of pulmonary hypertension in mitral stenosis. , 1973, The American journal of cardiology.