Infrared imaging for leak detection of N95 filtering facepiece respirators: a pilot study.
暂无分享,去创建一个
Michael S Bergman | Raymond J Roberge | Ronald Shaffer | William D Monaghan | R. Roberge | Andrew J. Palmiero | M. Bergman | Andrew J Palmiero | R. Shaffer | W. Monaghan
[1] C. Knapp,et al. Health care workers' views about respirator use and features that should be included in the next generation of respirators , 2009, American Journal of Infection Control.
[2] A Sreenath,et al. A modified protocol for quantitative fit testing using the PortaCount. , 2001, Applied occupational and environmental hygiene.
[3] Ziqing Zhuang,et al. Correlation Between Respirator Fit and Respirator Fit Test Panel Cells by Respirator Size , 2008, Journal of occupational and environmental hygiene.
[4] Dennis J. Viscusi,et al. Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Odor, Comfort, and Donning Ease , 2011, Journal of occupational and environmental hygiene.
[5] Jeffrey B. Powell,et al. Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators. , 2010, The Annals of occupational hygiene.
[6] R K Oestenstad,et al. Distribution of faceseal leak sites on a half-mask respirator and their association with facial dimensions. , 1990, American Industrial Hygiene Association journal.
[7] P. McCarthy,et al. Thermal screening of facial skin arterial hot spots using non-contact infrared radiometry , 2008, Physiological measurement.
[8] Bryan F. Jones,et al. A reappraisal of the use of infrared thermal image analysis in medicine , 1998, IEEE Transactions on Medical Imaging.
[9] Don-Hee Han,et al. Evaluation of particulate filtering respirators using inward leakage (IL) or total inward leakage (TIL) testing--Korean experience. , 2005, The Annals of occupational hygiene.
[10] Paul A. Jensen,et al. Reducing Respirator Fit Test Errors: A Multi-Donning Approach , 2005 .
[11] S. Lam,et al. Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators , 2011, Journal of Hospital Infection.
[12] Filippo Molinari,et al. Noise Estimation in Infrared Image Sequences: A Tool for the Quantitative Evaluation of the Effectiveness of Registration Algorithms , 2008, IEEE Transactions on Biomedical Engineering.
[13] K. Dubowski. Studies in breath-alcohol analysis: Biological factors , 1975, Zeitschrift für Rechtsmedizin.
[14] E.Y.K. Ng,et al. Study of facial skin and aural temperature , 2006, IEEE Engineering in Medicine and Biology Magazine.
[15] T. Chau,et al. Infrared thermography as an access pathway for individuals with severe motor impairments , 2009, Journal of NeuroEngineering and Rehabilitation.
[16] Mike Clayton,et al. Fit for purpose? The role of fit testing in respiratory protection. , 2005, The Annals of occupational hygiene.
[17] D. Musher. How contagious are common respiratory tract infections? , 2003, The New England journal of medicine.
[18] J. Steketee. Spectral emissivity of skin and pericardium. , 1973, Physics in medicine and biology.
[19] J L Derrick,et al. Predictive value of the user seal check in determining half-face respirator fit , 2004, Journal of Hospital Infection.
[20] M. Buono,et al. Comparison of infrared versus contact thermometry for measuring skin temperature during exercise in the heat , 2007, Physiological measurement.
[21] T. Conine,et al. Assessment of an infra-red non-contact sensor for routine skin temperature monitoring: a preliminary study. , 1992, Journal of medical engineering & technology.
[22] Tiina Reponen,et al. Laboratory and field evaluation of a new personal sampling system for assessing the protection provided by the N95 filtering facepiece respirators against particles. , 2005, The Annals of occupational hygiene.
[23] I. Pavlidis,et al. Noncontact measurement of breathing function , 2006, IEEE Engineering in Medicine and Biology Magazine.
[24] Jan Rustemeyer,et al. Thermography and thermoregulation of the face , 2007, Head & face medicine.
[25] Riedar Kent Oestenstad,et al. Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators , 2010, Journal of occupational and environmental hygiene.
[26] Lisa M Brosseau,et al. Surgical mask filter and fit performance , 2008, American Journal of Infection Control.
[27] Jonathan B. Dowdall,et al. Thermal image analysis for detecting facemask leakage , 2005, SPIE Defense + Commercial Sensing.
[28] A. Jones. Quantitative measurements of the alcohol concentration and the temperature of breath during a prolonged exhalation. , 1982, Acta physiologica Scandinavica.