Comparision between bed side testing of blood glucose by glucometer vs centralized testing in a tertiary care hospital.

BACKGROUND To determine the accuracy, turnaround time and cost effectiveness of bedside monitoring of blood glucose levels by non-laboratory health care workers and centralized testing of blood glucose by automated analyzer in a tertiary care hospital. METHODS The study was conducted in Section of Chemical Pathology, Department of Pathology and Microbiology and Section of Endocrinology Department of Medicine, Aga Khan University and Hospital Karachi, from April 2005 to March 2006. One hundred and ten patients were included in the study. The blood glucose levels were analyzed on glucometer (Precision Abbott) by finger stick, using Biosensor Technology. At the same time venous blood was obtained to analyze glucose in clinical laboratory on automated analyzer (SYNCHRON CX7) by glucose oxidase method. RESULTS We observed good correlation between bed side glucometer and laboratory automated analyzer for glucose values between 3.3 mmol/L (60 mg/dl) and 16.7 (300 mg/dl). A significant difference was observed for glucose values less than 3.3 mmol/L (p = 0.002) and glucose values more than 16.67 mmol/l (p = 0.049). Mean Turnaround time for glucometer and automated analyzer were 0.08 hours and 2.49 hours respectively. The cost of glucose testing with glucometer was 48.8% lower than centralized lab based testing. CONCLUSION Bedside glucometer testing, though less expensive does not have good accuracy in acutely ill patient with either very high or very low blood glucose levels.

[1]  S. Saxena,et al.  Does the emergency department need a dedicated stat laboratory? Continuous quality improvement as a management tool for the clinical laboratory. , 1993, American journal of clinical pathology.

[2]  J. P. Vandorsten,et al.  Glucometer analysis of one-hour glucose challenge samples. , 1997, American journal of obstetrics and gynecology.

[3]  Z. Trajanoski,et al.  Accuracy of home blood glucose meters during hypoglycemia , 1996, Diabetes Care.

[4]  R. M. Greendyke Cost analysis. Bedside blood glucose testing. , 1992, American journal of clinical pathology.

[5]  L. Sarkozi,et al.  Analytical evaluation of i-STAT Portable Clinical Analyzer and use by nonlaboratory health-care professionals. , 1993, Clinical chemistry.

[6]  Analytical Evaluation of iSTAT Portable Clinical Analyzer and Use by Nonlaboratory Health-Care Professionals , 2004 .

[7]  J W Winkelman,et al.  The fiscal consequences of central vs distributed testing of glucose. , 1994, Clinical chemistry.

[8]  B A Friedman,et al.  Integrating information from decentralized laboratory testing sites. The creation of a value-added network. , 1993, American journal of clinical pathology.

[9]  Suzanne H. Atkin,et al.  Fingerstick glucose determination in shock. , 1991, Annals of internal medicine.

[10]  I Hinberg,et al.  Near-patient testing. Quality of laboratory test results obtained by non-technical personnel in a decentralized setting. , 1988, American journal of clinical pathology.

[11]  G J Kost,et al.  Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing. , 2000, Archives of pathology & laboratory medicine.

[12]  J. Nosanchuk,et al.  Cost analysis of point-of-care laboratory testing in a community hospital. , 1995, American journal of clinical pathology.