Internal elemental microanalysis combining x-ray fluorescence, Compton and transmission tomography

Conventional x-ray transmission tomography provides the spatial distribution of the absorption coefficient inside a sample. Other tomographic techniques, based on the detection of photons coming from fluorescent emission, Compton and Rayleigh scattering, are used for obtaining information on the internal elemental composition of the sample. However, the reconstruction problem for these techniques is generally much more difficult than that of transmission tomography, mainly due to self-absorption effects in the sample. In this article an approach to the reconstruction problem is presented, which integrates the information from the three types of signals. This method provides the quantitative spatial distribution of all elements that emit detectable fluorescent lines (Z15 in usual experimental conditions), even when the absorption effects are strong, and the spatial distribution of the global density of the lighter elements. The use of this technique is demonstrated on the reconstruction of a grain of the martian meteorite NWA817, mainly composed of low Z elements not measured in fluorescence and for which this method provides a unique insight. The measurement was done at the ID22 beamline of the European Synchrotron Radiation Facility.

[1]  Koen Janssens,et al.  Analysis of X‐ray spectra by iterative least squares (AXIL): New developments , 1994 .

[2]  J. A. Grant,et al.  Reconstruction strategy suited to x-ray diffraction tomography , 1995 .

[3]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[4]  Anatoly Snigirev,et al.  Synchrotron hard x-ray microprobe: Fluorescence imaging of single cells , 2001 .

[5]  K. Tanabe Projection method for solving a singular system of linear equations and its applications , 1971 .

[6]  Andrea Somogyi,et al.  XANES micro-imaging and tomography , 2002, Optics + Photonics.

[7]  Koen Janssens,et al.  High resolution x-ray fluorescence microtomography on single sediment particles , 2002, Optics + Photonics.

[8]  Irina Snigireva,et al.  Imaging by parabolic refractive lenses in the hard X-ray range , 1999 .

[9]  J. Weigelt,et al.  X-ray fluorescent computer tomography with synchrotron radiation , 1998 .

[10]  D. Solmon,et al.  The angles between the null spaces of X rays , 1978 .

[11]  R. Gonsalves,et al.  Fluorescent computer tomography: a model for correction of X-ray absorption , 1991 .

[12]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[13]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[14]  Peter J. Eng,et al.  Geoscience applications of x-ray computed microtomography , 1999, Optics & Photonics.

[15]  Tetsuya Yuasa,et al.  Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition , 1997 .

[16]  Derrick C. Mancini,et al.  High-throughput real-time x-ray microtomography at the Advanced Photon Source , 2002, Optics + Photonics.

[17]  Erik H. Anderson,et al.  Nanotomography of labeled cryogenic cells , 2002, Optics + Photonics.

[18]  R. Ketcham,et al.  Acquisition, optimization and interpretation of X-ray computed tomographic imagery: applications to the geosciences , 2001 .

[19]  Gabor T. Herman,et al.  Relaxation methods for image reconstruction , 1978, CACM.

[20]  Kentaro Uesugi,et al.  Development of submicrometer resolution x-ray CT system at SPring-8 , 2002, Optics + Photonics.

[21]  V. Sautter,et al.  A new Martian meteorite from Morocco: the nakhlite North West Africa 817 , 2002 .

[22]  Koen Janssens,et al.  Monte Carlo simulation of X-ray fluorescence spectra: Part 4. Photon scattering at high X-ray energies , 1999 .

[23]  Roberto Cesareo,et al.  A new tomographic device based on the detection of fluorescent x-rays , 1989 .

[24]  Bruno Golosio,et al.  Software for x-ray fluorescence and scattering tomographic reconstruction , 2001 .

[25]  C. Schroer Reconstructing x-ray fluorescence microtomograms , 2001 .

[26]  M. Chukalina,et al.  High-resolution X-ray fluorescence microtomography of homogeneous samples , 2000 .

[27]  Gilles Peix,et al.  Rayleigh to Compton ratio computed tomography using synchrotron radiation , 2000 .

[28]  Koen Janssens,et al.  Monte Carlo simulation of x-ray fluorescence and scattering tomography experiments , 1999, Optics & Photonics.