Comparison of Segmentation-Based Attenuation Correction Methods for PET/MRI: Evaluation of Bone and Liver Standardized Uptake Value with Oncologic PET/CT Data

For attenuation correction (AC) in PET/MRI systems, segmentation-based methods are most often used. However, the standardized uptake value (SUV) of lesions in the bone and liver, which have higher attenuation coefficients than other organs, can be underestimated, potentially leading to misinterpretation of clinical cases. Errors in SUV estimation are also dependent on the segmentation schemes used in the segmentation-based AC. In this study, this potential bias in SUV estimation using 4 different segmentation-based AC methods was evaluated for the PET/CT data of cancer patients with bone and liver lesions. Methods: Forty patients who had spine or liver lesions and underwent 18F-FDG PET/CT participated (18 women and 22 men; 20 spine lesions and 20 liver lesions; mean age (±SD), 60.5 ± 11.4 y; mean body weight, 57.7 ± 10.4 kg). The patient body region was extracted from the CT image and categorized into 5 tissue groups (air, lungs, fat, water, and bone) using Hounsfield unit thresholds, which were determined from the CT histogram. Four segmentation-based AC methods (SLA [soft-tissue/lung/air], WFLA [water/fat/lung/air], SLAB [soft-tissue/lung/air/bone], and WFLAB [water/fat/lung/air/bone]) were compared with CT-based AC. The mean attenuation coefficient for each group was calculated from 40 CT images and assigned to the attenuation maps. PET sinograms were reconstructed using segmentation- and CT-based AC maps, and mean SUV in the lesions was compared. Results: Mean attenuation coefficients for air, lungs, fat, water, and bone were 0.0058, 0.0349, 0.0895, 0.0987, and 0.1178 cm−1, respectively. In the spine lesions, the SUVs were underestimated by 16.4% ± 8.5% (SLA AC) and 14.7% ± 7.5% (WFLA AC) but not to a statistically significant extent for SLAB and WFLAB AC relative to CT AC. In the liver lesions, the SUVs were underestimated by 11.1% ± 2.6%, 8.1% ± 3.0%, 6.8% ± 3.8%, and 4.1% ± 3.8% with SLA, SLAB, WFLA, and WFLAB AC, respectively. Conclusion: Without bone segmentation, the SUVs of spine lesions were considerably underestimated; however, the bias was acceptable with bone segmentation. In liver lesions, the segmentation-based AC methods yielded a negative bias in SUV; however, inclusion of the bone and fat segments reduced the SUV bias. The results of this study will be useful for understanding organ-dependent bias in SUV between PET/CT and PET/MRI.

[1]  Tobias Schaeffter,et al.  The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images , 2010, Nuclear medicine communications.

[2]  Guy B. Williams,et al.  Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches , 2011, The Journal of Nuclear Medicine.

[3]  B. Schölkopf,et al.  Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[4]  Nassir Navab,et al.  Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data , 2009, Journal of Nuclear Medicine.

[5]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[6]  Ilja Bezrukov,et al.  MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods , 2011, The Journal of Nuclear Medicine.

[7]  H. Zaidi,et al.  Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system , 2011, Physics in medicine and biology.

[8]  Eiji Sugiyama,et al.  Design and performance from an integrated PET/MRI system for small animals , 2010, Annals of nuclear medicine.

[9]  I. Burger,et al.  PET/MR imaging of bone lesions – implications for PET quantification from imperfect attenuation correction , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[10]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[11]  Jae Sung Lee,et al.  Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET Scanner , 2012, The Journal of Nuclear Medicine.

[12]  Adam Johansson,et al.  CT substitute derived from MRI sequences with ultrashort echo time. , 2011, Medical physics.

[13]  Christoph Palm,et al.  MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[14]  Jun Zhang,et al.  Three-region MRI-based whole-body attenuation correction for automated PET reconstruction. , 2010, Nuclear medicine and biology.

[15]  Thomas Beyer,et al.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. , 2003, Seminars in nuclear medicine.

[16]  D. Townsend,et al.  Method for transforming CT images for attenuation correction in PET/CT imaging. , 2006, Medical physics.

[17]  Eduard Schreibmann,et al.  MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration. , 2010, Medical physics.

[18]  Scott Metzler,et al.  Nuclear Science Symposium Medical Imaging Conference , 2002 .

[19]  Ciprian Catana,et al.  Simultaneous PET-MRI: a new approach for functional and morphological imaging , 2008, Nature Medicine.

[20]  Matthias Hofmann,et al.  Hybrid PET/MRI of Intracranial Masses: Initial Experiences and Comparison to PET/CT , 2010, The Journal of Nuclear Medicine.

[21]  S. Cherry,et al.  Simultaneous in vivo positron emission tomography and magnetic resonance imaging , 2008, Proceedings of the National Academy of Sciences of the United States of America.

[22]  B. Pichler,et al.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[23]  R. Günther,et al.  Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data , 2010, European Journal of Nuclear Medicine and Molecular Imaging.

[24]  Bernhard Schölkopf,et al.  MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration , 2008, Journal of Nuclear Medicine.

[25]  A. Buck,et al.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[26]  G. Delso,et al.  Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner , 2011, The Journal of Nuclear Medicine.