Choosing heat sinks for cooling in tropical climates

Abstract Efforts to limit CO2 emissions from buildings in the tropics either focus on reducing energy demand, i.e., air-conditioning, or on replacing fossil with renewable sources. The link between energy demand and supply is often overlooked, especially the effect of the temperature lift of air-conditioning systems on energy consumption. But while heat and humidity gains define energy demand, operating temperatures of the system define the necessary energy input. We aim to transfer our experience of using the LowEx paradigm for heat pump systems in moderate climates to the tropical climate of Singapore. In this paper, we took a systematic overview of a range of heat sinks, to which we refer to as anergy sinks. We analysed their thermal properties and their effect on the performance of air-conditioning systems, expressed as COP. The predominantly used dry air-cooled condenser units performed worst, especially when subject to a stack effect in (semi-)confined spaces. The performance is highest for cooling towers using the wet bulb temperature followed by water body based anergy sinks and the soil. The wide spread of results confirms that the heat rejection temperature is a decisive factor for the performance of the overall cooling system and the input of primary energy.

[1]  Philippe Goffin,et al.  Low exergy building systems implementation , 2012 .

[2]  Adriana Angelotti,et al.  Exergy analysis of renewable energy-based climatisation systems for buildings: A critical view , 2009 .

[3]  Wong Nyuk Hien,et al.  Microclimatic modeling of the urban thermal environment of Singapore to mitigate urban heat island , 2008 .

[4]  Hansjürg Leibundgut,et al.  The reference environment: utilising exergy and anergy for buildings , 2012 .

[5]  Kwan-Soo Lee,et al.  Effects of stacked condensers in a high-rise apartment building , 2005 .

[6]  Werner Sobek,et al.  Reduce CO2 from buildings with technology to zero emissions , 2012 .

[7]  Zhang Lin,et al.  Prediction of on-coil temperature of condensers installed at tall building re-entrant , 1999 .

[8]  Dietrich Schmidt Low Exergy Systems for High-Performance Buildings and Communities , 2009 .

[9]  Francis W.H. Yik,et al.  Flow and temperatures outside a high-rise residential building due to heat rejection by its air-conditioners , 2001 .

[10]  N. Mendes,et al.  Ground temperature and moisture distribution using different weather patterns , 2008 .

[11]  Hansjürg Leibundgut,et al.  LowEx Solar Building System: Integration of PV/T Collectors into Low Exergy Building Systems☆ , 2012 .

[12]  Milorad Bojić,et al.  Influence of air-conditioning exhaust on exterior recessed space , 2003 .

[14]  Masanori Shukuya,et al.  Exergy concept and its application to the built environment , 2009 .

[15]  Lenore Newman,et al.  The use of deep water cooling systems: Two Canadian examples , 2009 .

[16]  T. Chow,et al.  Estimation of soil temperature profile in Hong Kong from climatic variables , 2011 .

[17]  Zhang Lin,et al.  Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance , 2002 .

[18]  Sheng Zhang,et al.  Dynamics and size structure of phytoplankton in the coastal waters of Singapore , 2000 .