Design of a textile composite bone plate using 3D-finite element method

Abstract Bone plates are the most common devices used for long bone fracture fixations. Metallic bone plates are conventionally used for load bearing regions suffer the disadvantages that they usually needs to be removed 1–2 years after surgery due to stress shielding and ion releasing effects. One solution to overcome these problems is to use bone plates made of composite materials with desirable mechanical properties as substitutes for the metallic types. In this research, a partially resorbable composite bone plate consisting of a poly L-Lactic acid matrix and textile bioglass fibers used as reinforcement was modeled and analyzed using the ANSYS software V. 9.0. Micromechanical study of a representative volume element (REV) was carried out using the 3D-finite element method to optimized volume fraction of the reinforcement. In this stage, ultimate tensile strength of the composite was determined. In the macromechanical analysis, a three dimensional, quarter symmetric finite element model was developed for a plate with five holes. Bending analysis was performed to determine the bending strength and the bending modulus of the plate. Results showed that for a volume fraction equal to 45%, the longitudinal modulus of elasticity and the ultimate tensile strength would be 23 GPa and 230 MPa, respectively. The bending strength and bending modulus of the plate were calculated to be about 55 MPa and 16.6 GPa, respectively. Compared to the data available on forearm bones in which the longitudinal modulus of elasticity is about 18 GPa, the tensile and bending strength are about 150 MPa and 40 MPa and the bending modulus is 7 GPa, it is concluded that the composite plate system is suitable for forearm region and it is capable of reducing stress shielding effects at the fracture site.

[1]  H Hamada,et al.  Performance study of braided carbon/PEEK composite compression bone plates. , 2003, Biomaterials.

[2]  Seeram Ramakrishna,et al.  Strain distribution analysis of braided composite bone plates , 2003 .

[3]  H. Hamada,et al.  Feasibility of knitted carbon/PEEK composites for orthopedic bone plates. , 2004, Biomaterials.

[4]  S. Ramakrishna,et al.  Biomedical applications of polymer-composite materials: a review , 2001 .

[5]  Joung-Man Park,et al.  Interfacial properties and microfailure degradation mechanisms of bioabsorbable fibers/poly-l-lactide composites using micromechanical test and nondestructive acoustic emission , 2003 .

[6]  L. Francis,et al.  Processing and properties of porous poly(L-lactide)/bioactive glass composites. , 2004, Biomaterials.

[7]  M. Nogami,et al.  Preparation and mechanical properties of polylactic acid composites containing hydroxyapatite fibers. , 2001, Biomaterials.

[8]  S. H. Saidpour,et al.  Assessment of Carbon Fibre Composite Fracture Fixation Plate Using Finite Element Analysis , 2006, Annals of Biomedical Engineering.

[9]  Seeram Ramakrishna,et al.  Fibrous composite materials in dentistry and orthopaedics: review and applications , 2004 .

[10]  H. Hamada,et al.  Influence of micro-structures on bending properties of braided laminated composites , 2007 .

[11]  M. Marcolongo,et al.  Effect of coupling agents on the local mechanical properties of bioactive dental composites by the nano-indentation technique. , 2005, Dental materials : official publication of the Academy of Dental Materials.

[12]  Masaki Hojo,et al.  Evaluation of interfacial strength in CF/epoxies using FEM and in-situ experiments , 2006 .

[13]  J. Carey,et al.  2D braided composites: A review for stiffness critical applications , 2008 .

[14]  Chaosuan Kanchanomai,et al.  Fatigue failure of an orthopedic implant – A locking compression plate , 2008 .

[15]  K. Arakawa,et al.  Relationship between microstructure and fracture behavior of bioabsorbable HA/PLLA composites , 2006 .

[16]  A. T. DiBenedetto,et al.  Tailoring of interfaces in glass fiber reinforced polymer composites: a review , 2001 .

[17]  J. R. Parsons,et al.  The design and analysis of a laminated partially degradable composite bone plate for fracture fixation. , 1987, Journal of biomedical materials research.

[18]  G. Giakas,et al.  The Load-Bearing Characteristics of the Forearm: Pattern of Axial and Bending Force Transmitted Through Ulna and Radius , 2006, Journal of hand surgery.

[19]  P. Vallittu,et al.  The influence of short-term water storage on the flexural properties of unidirectional glass fiber-reinforced composites. , 2002, Biomaterials.

[20]  K. Fujihara,et al.  Stiffness and strength design of composite bone plates , 2005 .

[21]  Thomas Schambron,et al.  Effects of environmental ageing on the static and cyclic bending properties of braided carbon fibre/PEEK bone plates , 2008 .

[22]  Zheng-Ming Huang,et al.  The mechanical properties of composites reinforced with woven and braided fabrics , 2000 .

[23]  Y. Shikinami,et al.  Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): Part I. Basic characteristics. , 1999, Biomaterials.

[24]  A. Waas,et al.  Braided textile composites under compressive loads : Modeling the response, strength and degradation , 2007 .

[25]  Takashi Nakamura,et al.  Formation of bone-like apatite on organic polymers treated with a silane-coupling agent and a titania solution. , 2006, Biomaterials.

[26]  P. Potluri,et al.  Mechanics of non-orthogonally interlaced textile composites , 2007 .

[27]  K. Tayton,et al.  How stiff should semi-rigid fixation of the human tibia be? A clue to the answer. , 1983, The Journal of bone and joint surgery. British volume.

[28]  Xiangdong Ding,et al.  Stress-strain behavior in initial yield stage of short fiber reinforced metal matrix composite , 2002 .