Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans.

PURPOSE The purpose of this study is to determine dose delivery errors that could result from random and systematic setup errors for head-and-neck patients treated using the simultaneous integrated boost (SIB)-intensity-modulated radiation therapy (IMRT) technique. METHODS AND MATERIALS Twenty-four patients who participated in an intramural Phase I/II parotid-sparing IMRT dose-escalation protocol using the SIB treatment technique had their dose distributions reevaluated to assess the impact of random and systematic setup errors. The dosimetric effect of random setup error was simulated by convolving the two-dimensional fluence distribution of each beam with the random setup error probability density distribution. Random setup errors of sigma = 1, 3, and 5 mm were simulated. Systematic setup errors were simulated by randomly shifting the patient isocenter along each of the three Cartesian axes, with each shift selected from a normal distribution. Systematic setup error distributions with Sigma = 1.5 and 3.0 mm along each axis were simulated. Combined systematic and random setup errors were simulated for sigma = Sigma = 1.5 and 3.0 mm along each axis. For each dose calculation, the gross tumor volume (GTV) received by 98% of the volume (D(98)), clinical target volume (CTV) D(90), nodes D(90), cord D(2), and parotid D(50) and parotid mean dose were evaluated with respect to the plan used for treatment for the structure dose and for an effective planning target volume (PTV) with a 3-mm margin. RESULTS Simultaneous integrated boost-IMRT head-and-neck treatment plans were found to be less sensitive to random setup errors than to systematic setup errors. For random-only errors, errors exceeded 3% only when the random setup error sigma exceeded 3 mm. Simulated systematic setup errors with Sigma = 1.5 mm resulted in approximately 10% of plan having more than a 3% dose error, whereas a Sigma = 3.0 mm resulted in half of the plans having more than a 3% dose error and 28% with a 5% dose error. Combined random and systematic dose errors with sigma = Sigma = 3.0 mm resulted in more than 50% of plans having at least a 3% dose error and 38% of the plans having at least a 5% dose error. Evaluation with respect to a 3-mm expanded PTV reduced the observed dose deviations greater than 5% for the sigma = Sigma = 3.0 mm simulations to 5.4% of the plans simulated. CONCLUSIONS Head-and-neck SIB-IMRT dosimetric accuracy would benefit from methods to reduce patient systematic setup errors. When GTV, CTV, or nodal volumes are used for dose evaluation, plans simulated including the effects of random and systematic errors deviate substantially from the nominal plan. The use of PTVs for dose evaluation in the nominal plan improves agreement with evaluated GTV, CTV, and nodal dose values under simulated setup errors. PTV concepts should be used for SIB-IMRT head-and-neck squamous cell carcinoma patients, although the size of the margins may be less than those used with three-dimensional conformal radiation therapy.

[1]  Joos V Lebesque,et al.  Biologic and physical fractionation effects of random geometric errors. , 2003, International journal of radiation oncology, biology, physics.

[2]  X Allen Li,et al.  Simultaneous integrated boost for breast cancer using IMRT: a radiobiological and treatment planning study. , 2004, International journal of radiation oncology, biology, physics.

[3]  R Mohan,et al.  Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers. , 2000, International journal of radiation oncology, biology, physics.

[4]  S. Senan,et al.  A treatment planning study evaluating a 'simultaneous integrated boost' technique for accelerated radiotherapy of stage III non-small cell lung cancer. , 2004, Lung cancer.

[5]  A. Dutreix When and how can we improve precision in radiotherapy? , 1984, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[7]  V Grégoire,et al.  Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  P J Keall,et al.  A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error. , 2002, Physics in medicine and biology.

[9]  Radhe Mohan,et al.  Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas: II--clinical results. , 2004, International journal of radiation oncology, biology, physics.

[10]  Alessandra Bolsi,et al.  Comparative dosimetric evaluation of the simultaneous integrated boost with photon intensity modulation in head and neck cancer patients. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  R Mohan,et al.  The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. , 2001, International journal of radiation oncology, biology, physics.

[12]  L. Dawson,et al.  Salivary Gland Sparing and Improved Target Irradiation by Conformal and Intensity Modulated Irradiation of Head and Neck Cancer , 2003, World Journal of Surgery.

[13]  Joos V Lebesque,et al.  Reduction of rectal dose by integration of the boost in the large-field treatment plan for prostate irradiation. , 2002, International journal of radiation oncology, biology, physics.

[14]  J Wong,et al.  The use of adaptive radiation therapy to reduce setup error: a prospective clinical study. , 1998, International journal of radiation oncology, biology, physics.

[15]  D Yan,et al.  An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. , 2000, International journal of radiation oncology, biology, physics.

[16]  J. Hendry,et al.  Prediction of the benefits from dose-escalated hypofractionated intensity-modulated radiotherapy for prostate cancer. , 2003, International journal of radiation oncology, biology, physics.

[17]  R. Mohan,et al.  Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas. I: dosimetric results. , 2003, International journal of radiation oncology, biology, physics.

[18]  R Mohan,et al.  The potential for sparing of parotids and escalation of biologically effective dose with intensity-modulated radiation treatments of head and neck cancers: a treatment design study. , 2000, International journal of radiation oncology, biology, physics.

[19]  M. Tubiana,et al.  An approach to the interpretation of clinical data on the tumour control probability-dose relationship. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  J Wong,et al.  Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors. , 1997, International journal of radiation oncology, biology, physics.

[21]  S. Dische,et al.  Precision in reporting the dose given in a course of radiotherapy , 1994 .

[22]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[23]  R K Ten Haken,et al.  Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer. , 1999, International journal of radiation oncology, biology, physics.

[24]  Joos V Lebesque,et al.  Inclusion of geometric uncertainties in treatment plan evaluation. , 2002, International journal of radiation oncology, biology, physics.

[25]  E. B. Butler,et al.  Smart (simultaneous modulated accelerated radiation therapy) boost: a new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[26]  M. Herk Errors and margins in radiotherapy. , 2004 .

[27]  J. Deasy,et al.  A prospective study of salivary function sparing in patients with head-and-neck cancers receiving intensity-modulated or three-dimensional radiation therapy: initial results. , 2001, International journal of radiation oncology, biology, physics.

[28]  R Mohan,et al.  Algorithms and functionality of an intensity modulated radiotherapy optimization system. , 2000, Medical physics.

[29]  Karl-Axel Johansson,et al.  Systematic set-up errors for IMRT in the head and neck region: effect on dose distribution. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  D P Dearnaley,et al.  Improvements in target coverage and reduced spinal cord irradiation using intensity-modulated radiotherapy (IMRT) in patients with carcinoma of the thyroid gland. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  Nesrin Dogan,et al.  Assessment of different IMRT boost delivery methods on target coverage and normal-tissue sparing. , 2003, International journal of radiation oncology, biology, physics.

[32]  Henk Huizenga,et al.  Set-up improvement in head and neck radiotherapy using a 3D off-line EPID-based correction protocol and a customised head and neck support. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[33]  J C Stroom,et al.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. , 1999, International journal of radiation oncology, biology, physics.

[34]  Yi-Min Hu,et al.  Comparison of conformal and intensity-modulated techniques for simultaneous integrated boost radiotherapy of upper esophageal carcinoma. , 2004, World journal of gastroenterology.