An introduction to photon-counting detector CT (PCD CT) for radiologists

[1]  L. Boussel,et al.  Coronary CT Angiography with Photon-counting CT: First-In-Human Results. , 2022, Radiology.

[2]  M. Greuter,et al.  Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic phantom study , 2022, The International Journal of Cardiovascular Imaging.

[3]  H. Alkadhi,et al.  Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality. , 2022, Radiology.

[4]  T. Leiner,et al.  Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study , 2022, European Radiology.

[5]  K. Awai,et al.  Dual-energy CT: minimal essentials for radiologists , 2022, Japanese Journal of Radiology.

[6]  F. Schwarz,et al.  Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT. , 2022, European journal of radiology.

[7]  R. Meuli,et al.  Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer , 2021, Diagnostics.

[8]  Jan-Robert Kroeger,et al.  Virtual Non-Contrast versus True Non-Contrast Computed Tomography: Initial Experiences with a Photon Counting Scanner Approved for Clinical Use , 2021, Diagnostics.

[9]  M. Greuter,et al.  Dose Reduction in Coronary Artery Calcium Scoring Using Mono-Energetic Images from Reduced Tube Voltage Dual-Source Photon-Counting CT Data: A Dynamic Phantom Study , 2021, Diagnostics.

[10]  H. Alkadhi,et al.  Tube voltage-independent coronary calcium scoring on a first-generation dual-source photon-counting CT—a proof-of-principle phantom study , 2021, The International Journal of Cardiovascular Imaging.

[11]  Jayasai R. Rajagopal,et al.  Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT. , 2021, Radiology. Cardiothoracic imaging.

[12]  C. McCollough,et al.  Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography: An Exploratory Animal Study. , 2021, Investigative radiology.

[13]  H. Alkadhi,et al.  High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose. , 2021, Investigative radiology.

[14]  H. Alkadhi,et al.  First Performance Evaluation of an Artificial Intelligence-Based Computer-Aided Detection System for Pulmonary Nodule Evaluation in Dual-Source Photon-Counting Detector CT at Different Low-Dose Levels. , 2021, Investigative radiology.

[15]  K. Awai,et al.  Advanced CT techniques for assessing hepatocellular carcinoma , 2021, La radiologia medica.

[16]  Jessica C. Hsu,et al.  In Vivo Molecular K-Edge Imaging of Atherosclerotic Plaque Using Photon-counting CT , 2021, Radiology.

[17]  M. Petersilka,et al.  Image Quality Assessment for Clinical Cadmium Telluride-Based Photon-Counting Computed Tomography Detector in Cadaveric Wrist Imaging , 2021, Investigative radiology.

[18]  M. Petersilka,et al.  Photon-Counting Computed Tomography for Coronary Stent Imaging , 2021, Investigative radiology.

[19]  Jeffrey F. Marsh,et al.  Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens , 2021, European Radiology.

[20]  M. Persson,et al.  Spectral photon-counting CT in cardiovascular imaging. , 2020, Journal of cardiovascular computed tomography.

[21]  D. Richardson,et al.  Early life ionizing radiation exposure and cancer risks: systematic review and meta-analysis , 2020, Pediatric Radiology.

[22]  A. Rodell,et al.  Dual-Energy CT for Suspected Radiographically Negative Wrist Fractures: A Prospective Diagnostic Test Accuracy Study. , 2020, Radiology.

[23]  C. McCollough,et al.  Multi-energy CT imaging for large patients using dual-source photon-counting detector CT , 2020, Physics in medicine and biology.

[24]  Emil Y. Sidky,et al.  Spectral CT metal artifact reduction using weighted masking and a One Step direct inversion reconstruction algorithm , 2020 .

[25]  C. McCollough,et al.  A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study. , 2020, Investigative radiology.

[26]  Cynthia H McCollough,et al.  Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study. , 2019, Medical physics.

[27]  Cynthia H McCollough,et al.  Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging , 2019, Physics in medicine and biology.

[28]  C. McCollough,et al.  Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance , 2019, Physics in medicine and biology.

[29]  Shuai Leng,et al.  Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. , 2019, Radiographics : a review publication of the Radiological Society of North America, Inc.

[30]  Chi Wan Koo,et al.  High-Resolution Chest Computed Tomography Imaging of the Lungs: Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography , 2019, Investigative radiology.

[31]  Amir Pourmorteza,et al.  Photon-counting CT: Technical Principles and Clinical Prospects. , 2018, Radiology.

[32]  C. McCollough,et al.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study , 2018, American Journal of Neuroradiology.

[33]  H. Alkadhi,et al.  Photon-Counting CT: High-Resolution Imaging of Coronary Stents , 2017, Investigative radiology.

[34]  Franz Pfeiffer,et al.  Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair , 2018, European Radiology.

[35]  Amir Pourmorteza,et al.  Photon‐counting CT for simultaneous imaging of multiple contrast agents in the abdomen: An in vivo study , 2017, Medical physics.

[36]  Shuai Leng,et al.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets , 2017, Physics in medicine and biology.

[37]  Bruno De Man,et al.  Model and reconstruction of a K-edge contrast agent distribution with an X-ray photon-counting detector. , 2017, Optics express.

[38]  Steffen Kappler,et al.  Low-dose lung cancer screening with photon-counting CT: a feasibility study , 2017, Physics in medicine and biology.

[39]  Xiaochuan Pan,et al.  An algorithm for constrained one-step inversion of spectral CT data , 2015, Physics in medicine and biology.

[40]  Christoph Hoeschen,et al.  Feasibility of spectral CT imaging for the detection of liver lesions with gold-based contrast agents - A simulation study. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[41]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[42]  M. Kachelriess,et al.  Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study. , 2015, Medical physics.

[43]  E. Samei,et al.  Dual-energy MDCT in hypervascular liver tumors: effect of body size on selection of the optimal monochromatic energy level. , 2014, AJR. American journal of roentgenology.

[44]  Ben Huber,et al.  Energy-resolved CT imaging with a photon-counting silicon-strip detector , 2014, Medical Imaging.

[45]  Mats Persson,et al.  Theoretical Comparison of the Iodine Quantification Accuracy of Two Spectral CT Technologies , 2014, IEEE Transactions on Medical Imaging.

[46]  D. Hansell,et al.  High-Resolution CT of Interstitial Lung Disease: A Continuous Evolution , 2014, Seminars in Respiratory and Critical Care Medicine.

[47]  R. Alvarez Dimensionality and noise in energy selective x-ray imaging. , 2013, Medical physics.

[48]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[49]  Shuai Leng,et al.  Dual-energy CT-based monochromatic imaging. , 2012, AJR. American journal of roentgenology.

[50]  Anthony P. H. Butler,et al.  Image Reconstruction for Hybrid True-Color Micro-CT , 2012, IEEE Transactions on Biomedical Engineering.

[51]  C. McCollough,et al.  Applications of dual-energy CT in urologic imaging: an update. , 2012, Radiologic clinics of North America.

[52]  S. Wildermuth,et al.  Dual- and multi-energy CT: approach to functional imaging , 2011, Insights into imaging.

[53]  Joel G Fletcher,et al.  Dual-source dual-energy CT with additional tin filtration: Dose and image quality evaluation in phantoms and in vivo. , 2010, AJR. American journal of roentgenology.

[54]  Axel Thran,et al.  Atherosclerotic Plaque Composition : Analysis with Multicolor CT and Targeted Gold Nanoparticles 1 , 2010 .

[55]  M. Danielsson,et al.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study , 2010, Physics in medicine and biology.

[56]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[57]  R. Alvarez Near optimal energy selective x-ray imaging system performance with simple detectors. , 2010, Medical physics.

[58]  C. McCollough,et al.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration. , 2009, Medical physics.

[59]  J. Iwanczyk,et al.  Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging , 2007, IEEE Transactions on Nuclear Science.

[60]  D. Hough,et al.  Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? , 2009, Radiologic clinics of North America.

[61]  P. Shikhaliev Energy-resolved computed tomography: first experimental results , 2008, Physics in medicine and biology.

[62]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[63]  Kazuo Awai,et al.  Improvement of Low-Contrast Detectability in Low-Dose Hepatic Multidetector Computed Tomography Using a Novel Adaptive Filter: Evaluation With a Computer-Simulated Liver Including Tumors , 2006, Investigative radiology.

[64]  Thomas L Toth,et al.  Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. , 2004, Radiology.

[65]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.