Validity of Skin, Oral and Tympanic Temperatures During Exercise in the Heat: Effects of Wind and Sweat

This experiment investigates the validity of six thermometers with different measuring sensors, operation and site of application, to estimate core temperature (Tc) in comparison to an ingestible thermometric sensor based on quartz crystal technology. Measurements were obtained before, during and after exercise in the heat, controlling the presence of air-cooling and skin sweating. Twelve well-trained men swallowed the ingestible thermometer 6 h before the trial. After pre-exercise resting measurements at 20 °C, subjects entered a heat chamber held at 40 °C. Exercise in the heat consisted of 60 min of pedalling on cycle ergometer at 90% of the individually determined first ventilatory threshold. Results reveal that wind and skin sweat invalidate the use of skin infrared thermometry to estimate Tc during exercise in the heat. However, better Tc estimations were obtained in wind-restricted situations. We detected important differences between same-technology devices but different models and brands. In conclusion, there are important limitations to assess Tc accurately using non-invasive thermometers during and after exercise in the heat. Because some devices showed better validity than others did, we recommended using tympanic Braun®, and non-contact skin infrared Medisana® or Visiofocus® in wind-restricted and no sweat conditions to estimate Tc during exercise in the heat.

[1]  James M. Rippe,et al.  Irwin and Rippe's intensive care medicine , 2003 .

[2]  Manuel Sillero Quintana,et al.  Time required to stabilize thermographic images at rest , 2014 .

[3]  R. Morán-Navarro,et al.  Validity of Hydration Non-Invasive Indices during the Weightcutting and Official Weigh-In for Olympic Combat Sports , 2014, PloS one.

[4]  Rosario Salvador Palmer,et al.  Effect of perspiration on skin temperature measurements by infrared thermography and contact thermometry during aerobic cycling , 2015 .

[5]  E. Sparrow,et al.  Non-invasive measurement of the human core temperature , 2011 .

[6]  A. While,et al.  Tympanic thermometry--normal temperature and reliability. , 2009, Paediatric nursing.

[7]  D. Altman,et al.  Agreement Between Methods of Measurement with Multiple Observations Per Individual , 2007, Journal of biopharmaceutical statistics.

[8]  Daniel S Moran,et al.  Core Temperature Measurement , 2002, Sports medicine.

[9]  A. Caumo,et al.  Thermal Imaging of Exercise-Associated Skin Temperature Changes in Trained and Untrained Female Subjects , 2013, Annals of Biomedical Engineering.

[10]  Ishag Adam,et al.  Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer , 2013, BMC Research Notes.

[11]  J. I. P. Quesada Application of Infrared Thermography in Sports Science , 2017 .

[12]  Christian Raschner,et al.  An Overview of Recent Application of Medical Infrared Thermography in Sports Medicine in Austria , 2010, Sensors.

[13]  Louise M Burke,et al.  American College of Sports Medicine position stand. Exercise and fluid replacement. , 2007, Medicine and science in sports and exercise.

[14]  A. de Haan,et al.  Telemetry pill versus rectal and esophageal temperature during extreme rates of exercise-induced core temperature change , 2012, Physiological measurement.

[15]  Douglas J Casa,et al.  Validity of devices that assess body temperature during outdoor exercise in the heat. , 2007, Journal of athletic training.

[16]  Douglas J Casa,et al.  Validity and reliability of devices that assess body temperature during indoor exercise in the heat. , 2009, Journal of athletic training.

[17]  Michael N. Sawka,et al.  Consensus recommendations on training and competing in the heat , 2015, Scandinavian journal of medicine & science in sports.

[18]  Ciro José Brito,et al.  Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography , 2014, Physiological measurement.

[19]  Ian B Stewart,et al.  Does the technique employed for skin temperature assessment alter outcomes? A systematic review , 2015, Physiological measurement.

[20]  Michael S Ferrara,et al.  National Athletic Trainers' Association Position Statement: Exertional Heat Illnesses. , 2015, Journal of athletic training.

[21]  Aaron J. E. Bach,et al.  The Systematic Bias of Ingestible Core Temperature Sensors Requires a Correction by Linear Regression , 2017, Front. Physiol..

[22]  N S Maxwell,et al.  Reliability and validity of skin temperature measurement by telemetry thermistors and a thermal camera during exercise in the heat. , 2014, Journal of thermal biology.

[23]  V. Fernández-Elías,et al.  Improvements on neuromuscular performance with caffeine ingestion depend on the time-of-day. , 2015, Journal of science and medicine in sport.

[24]  P. Ouyang,et al.  Are fitness, activity, and fatness associated with health-related quality of life and mood in older persons? , 2003, Journal of cardiopulmonary rehabilitation.

[25]  D. Giavarina Understanding Bland Altman analysis , 2015, Biochemia medica.

[26]  Ian B. Stewart,et al.  A Comparison between Conductive and Infrared Devices for Measuring Mean Skin Temperature at Rest, during Exercise in the Heat, and Recovery , 2015, PloS one.

[27]  R. Mora‐Rodriguez Influence of Aerobic Fitness on Thermoregulation During Exercise in the Heat , 2012, Exercise and sport sciences reviews.

[28]  Sebastien Racinais,et al.  Heat Acclimation Decay and Re-Induction: A Systematic Review and Meta-Analysis , 2017, Sports Medicine.

[29]  Jesús G. Pallarés,et al.  Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists , 2016, PloS one.

[30]  Michael N. Sawka,et al.  Cardiovascular adaptations supporting human exercise-heat acclimation , 2016, Autonomic Neuroscience.

[31]  Felipe Pivetta Carpes,et al.  Methodological Aspects of Infrared Thermography in Human Assessment , 2017 .

[32]  V. Candas,et al.  Oral temperature as an index of core temperature during heat transients , 2004, European Journal of Applied Physiology and Occupational Physiology.

[33]  M. Sawka,et al.  PHYSICAL EXERCISE IN HOT CLIMATES: PHYSIOLOGY, PERFORMANCE, AND BIOMEDICAL ISSUES , 2002 .

[34]  V. Bernard,et al.  Infrared camera assessment of skin surface temperature--effect of emissivity. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[35]  Joanne N. Caldwell,et al.  Heat strain during military training activities: The dilemma of balancing force protection and operational capability , 2016, Temperature.

[36]  H. Daanen,et al.  Reliability of an infrared forehead skin thermometer for core temperature measurements , 2006, Journal of medical engineering & technology.

[37]  G. Kenny,et al.  Considerations for the measurement of core, skin and mean body temperatures. , 2014, Journal of thermal biology.

[38]  B. Richardson,et al.  Enhancing peer support for pre-registration students. , 2009, Paediatric nursing.

[39]  J. Coso,et al.  Infrared Tympanic Thermometry in a Hot Environment , 2008, International journal of sports medicine.