Rapid annotation of seizures and interictal-ictal-injury continuum EEG patterns

BACKGROUND Manual annotation of seizures and interictal-ictal-injury continuum (IIIC) patterns in continuous EEG (cEEG) recorded from critically ill patients is a time-intensive process for clinicians and researchers. In this study, we evaluated the accuracy and efficiency of an automated clustering method to accelerate expert annotation of cEEG. NEW METHOD We learned a local dictionary from 97 ICU patients by applying k-medoids clustering to 592 features in the time and frequency domains. We utilized changepoint detection (CPD) to segment the cEEG recordings. We then computed a bag-of-words (BoW) representation for each segment. We further clustered the segments by affinity propagation. EEG experts scored the resulting clusters for each patient by labeling only the cluster medoids. We trained a random forest classifier to assess validity of the clusters. RESULTS Mean pairwise agreement of 62.6% using this automated method was not significantly different from interrater agreements using manual labeling (63.8%), demonstrating the validity of the method. We also found that it takes experts using our method 5.31 ± 4.44 min to label the 30.19 ± 3.84 h of cEEG data, more than 45 times faster than unaided manual review, demonstrating efficiency. COMPARISON WITH EXISTING METHODS Previous studies of EEG data labeling have generally yielded similar human expert interrater agreements, and lower agreements with automated methods. CONCLUSIONS Our results suggest that long EEG recordings can be rapidly annotated by experts many times faster than unaided manual review through the use of an advanced clustering method.

[1]  R. Shellhaas,et al.  Assessment of neonatal electroencephalography (EEG) background by conventional and two amplitude-integrated EEG classification systems. , 2008, The Journal of pediatrics.

[2]  Daniel Friedman,et al.  Continuous Electroencephalogram Monitoring in the Intensive Care Unit , 2009, Anesthesia and analgesia.

[3]  M. Brandon Westover,et al.  Quantification of EEG reactivity in comatose patients , 2016, Clinical Neurophysiology.

[4]  Justin Dauwels,et al.  Rapid Annotation of Seizures and Interictal-ictal Continuum EEG Patterns , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[5]  R. Lund,et al.  Changepoint Detection in Periodic and Autocorrelated Time Series , 2007 .

[6]  Lawrence J. Hirsch,et al.  Classification of EEG patterns in patients with impaired consciousness , 2011, Epilepsia.

[7]  Peter W. Kaplan,et al.  Generalized periodic discharges and ‘triphasic waves’: A blinded evaluation of inter-rater agreement and clinical significance , 2016, Clinical Neurophysiology.

[8]  Brendan J. Frey,et al.  Non-metric affinity propagation for unsupervised image categorization , 2007, 2007 IEEE 11th International Conference on Computer Vision.

[9]  Olga Sourina,et al.  Large-Scale Automated Sleep Staging , 2017, Sleep.

[10]  J. C. Sackellares,et al.  Inter-rater agreement on identification of electrographic seizures and periodic discharges in ICU EEG recordings , 2015, Clinical Neurophysiology.

[11]  Suvadeep Bose,et al.  EEG signal analysis for Seizure detection using Discrete Wavelet Transform and Random Forest , 2017, 2017 International Conference on Computer and Applications (ICCA).

[12]  P. Fearnhead,et al.  Optimal detection of changepoints with a linear computational cost , 2011, 1101.1438.

[13]  Jaideep Srivastava,et al.  Event detection from time series data , 1999, KDD '99.

[14]  M. Westover,et al.  Interrater agreement for Critical Care EEG Terminology , 2014, Epilepsia.

[15]  Mahmoud Hassan,et al.  EEGNET: An Open Source Tool for Analyzing and Visualizing M/EEG Connectome , 2015, PloS one.

[16]  Lawrence J. Hirsch,et al.  Interrater Reliability of ICU EEG Research Terminology , 2012, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[17]  Joseph Picone,et al.  Deep Architectures for Automated Seizure Detection in Scalp EEGs , 2017, ArXiv.

[18]  Joseph Sullivan,et al.  Interrater agreement in the interpretation of neonatal electroencephalography in hypoxic‐ischemic encephalopathy , 2017, Epilepsia.

[19]  L. Hirsch Continuous EEG Monitoring in the Intensive Care Unit: An Overview , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[20]  Ryan P. Adams,et al.  Bayesian Online Changepoint Detection , 2007, 0710.3742.

[21]  J. Sackellares,et al.  Quantitative EEG analysis for automated detection of nonconvulsive seizures in intensive care units , 2011, Epilepsy & Behavior.

[22]  Robert Lund,et al.  A Review and Comparison of Changepoint Detection Techniques for Climate Data , 2007 .

[23]  Jan Claassen,et al.  How I Treat Patients with EEG Patterns on the Ictal–Interictal Continuum in the Neuro ICU , 2009, Neurocritical care.

[24]  Rong Jin,et al.  Understanding bag-of-words model: a statistical framework , 2010, Int. J. Mach. Learn. Cybern..

[25]  M. Nuwer,et al.  American Clinical Neurophysiology Society's Standardized Critical Care EEG Terminology: 2012 version. , 2013, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[26]  William B. S. Pressly,et al.  Web-Based Collection of Expert Opinion on Routine Scalp EEG: Software Development and Interrater Reliability , 2011, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[27]  Geoffrey E. Hinton,et al.  Visualizing Data using t-SNE , 2008 .

[28]  J. L. Rogers,et al.  Using significance tests to evaluate equivalence between two experimental groups. , 1993, Psychological bulletin.

[29]  N. Fountain,et al.  Assessment of acute morbidity and mortality in nonconvulsive status epilepticus , 2003, Neurology.

[30]  Emery N. Brown,et al.  A Review of Multitaper Spectral Analysis , 2014, IEEE Transactions on Biomedical Engineering.

[31]  S. L. Shishkin,et al.  Application of the change-point analysis to the investigation of the brain’s electrical activity , 2000 .

[32]  J. S. Barlow,et al.  Automatic adaptive segmentation of clinical EEGs. , 1981, Electroencephalography and clinical neurophysiology.

[33]  E. Gerard,et al.  Continuous EEG Monitoring in the Intensive Care Unit , 2012, Current Neurology and Neuroscience Reports.