Computational models for contact current dosimetry at frequencies below 1 MHz

Electric contact currents (CC) can cause muscle contractions, burns, or ventricular fibrillation which may result in life-threatening situations. In vivo studies with CC are rare due to potentially hazardous effects for participants. Cadaver studies are limited to the range of tissue’s electrical properties and the utilized probes’ size, relative position, and sensitivity. Thus, the general safety standards for protection against CC depend on a limited scientific basis. The aim of this study was therefore to develop an extendable and adaptable validated numerical body model for computational CC dosimetry for frequencies between DC and 1 MHz. Applying the developed model for calculations of the IEC heart current factors (HCF) revealed that in the case of transversal CCs, HCFs are frequency dependent, while for longitudinal CCs, the HCFs seem to be unaffected by frequency. HCFs for current paths from chest or back to hand appear to be underestimated by the International Electrotechnical Commission (IEC 60479-1). Unlike the HCFs provided in IEC 60479-1 for longitudinal current paths, our work predicts the HCFs equal 1.0, possibly due to a previously unappreciated current flow through the blood vessels. However, our results must be investigated by further research in order to make a definitive statement. Contact currents of frequencies from DC up to 100 kHz were conducted through the numerical body model Duke by seven contact electrodes on longitudinal and transversal paths. The resulting induced electric field and current enable the evaluation of the body impedance and the heart current factors for each frequency and current path.

[1]  G. Cho,et al.  Alterations in arterial function after high-voltage electrical injury , 2012, Critical Care.

[2]  H. Freiberger,et al.  Der elektrische Widerstand des menschlichen Körpers gegen technischen Gleich- und Wechselstrom , 1934 .

[3]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[4]  O. Gandhi,et al.  Human Body Impedance and Threshold Currents for Perception and Pain for Contact Hazard Analysis in the VLF-MF Band , 1986, IEEE Transactions on Biomedical Engineering.

[5]  Charles F. Dalziel,et al.  Electric shock hazard , 1972, IEEE Spectrum.

[6]  K. Duff,et al.  Electrical Injury and Lightning Injury: A Review of Their Mechanisms and Neuropsychological, Psychiatric, and Neurological Sequelae , 2001, Neuropsychology Review.

[7]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[8]  C. Gabriel Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies. , 1996 .

[9]  Niels Kuster,et al.  The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulations , 2010, Physics in medicine and biology.

[10]  K. Jokela,et al.  ICNIRP Guidelines GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING , 1998 .

[11]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[12]  J. G. Webster,et al.  Changes in electrical resistivity of swine liver after occlusion and postmortem , 2006, Medical and Biological Engineering and Computing.

[13]  Akimasa Hirata,et al.  Low-frequency electrical dosimetry: research agenda of the IEEE International Committee on Electromagnetic Safety. , 2016, Physics in medicine and biology.

[14]  K. Meyer-Waarden,et al.  Ermittlung der mittleren gefährlichen Gesamtstromstärken bei elektrischer Durchströmung des Menschen mittels dreidimensionaler, numerischer Berechnungen in einem aus computertomographischen Daten erstellten Modell , 1984 .

[15]  E. Neufeld,et al.  IT’IS Database for Thermal and Electromagnetic Parameters of Biological Tissues , 2012 .

[16]  Maria A. Stuchly,et al.  Electric fields in the human body resulting from 60-Hz contact currents , 2001, IEEE Transactions on Biomedical Engineering.

[17]  Laura Cercenelli,et al.  A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation , 2018, Sensors.

[18]  C. Andrews A Review of the Psychological Consequences of Lightning and Electrical Injury , 2014 .

[19]  K. Foster,et al.  Anisotropy in the dielectric properties of skeletal muscle , 2006, Medical and Biological Engineering and Computing.

[20]  Akimasa Hirata,et al.  Computational dosimetry for grounded and ungrounded human models due to contact current. , 2013, Physics in medicine and biology.

[21]  R. A. Malkin,et al.  Frequency dependence of the cardiac threshold to alternating current between 10 Hz and 160 Hz , 2006, Medical and Biological Engineering and Computing.

[22]  Mark Potse,et al.  Guidance for catheter ablation of ventricular arrhythmia , 2009, Medical & Biological Engineering & Computing.

[23]  L. Korpinen,et al.  Effects of tissue conductivity and electrode area on internal electric fields in a numerical human model for ELF contact current exposures. , 2012, Physics in medicine and biology.

[24]  U. SAM,et al.  Untersuchungen über die elektrische Gefährdung des Menschen bei Teildurchströmungen, insbesondere bei Arbeiten in Kesseln, Behältern und Rohrleitungen (2. Teil) , 1967 .

[25]  A. Hirata,et al.  Computational dosimetry for child and adult human models due to contact current from 10 Hz to 110 MHz. , 2015, Radiation protection dosimetry.

[26]  Christopher J. Andrews,et al.  Further Documentation of Remote Effects of Electrical Injuries, With Comments on the Place of Neuropsychological Testing and Functional Scanning , 2006, IEEE Transactions on Biomedical Engineering.

[27]  Optimal frequency of radiofrequency catheter ablation in vitro and in vivo for treating ventricular tachycardias--a study using various frequencies. , 1993, Japanese circulation journal.

[28]  Charles F. Dalziel,et al.  Lethal electric currents , 1969, IEEE Spectrum.

[29]  C. F. Dalziel,et al.  Reevaluation of Lethal Electric Currents , 1968 .

[30]  C. Breugem,et al.  High Voltage Electrical Injury Leading to a Delayed Onset Tetraplegia, with Recovery , 1999, Annals of the New York Academy of Sciences.

[31]  C. Gabriel,et al.  Electrical conductivity of tissue at frequencies below 1 MHz , 2009, Physics in medicine and biology.

[32]  J.G. Webster,et al.  The mosaic electrical characteristics of the skin , 1993, IEEE Transactions on Biomedical Engineering.

[33]  D. Panescu,et al.  A nonlinear electrical-thermal model of the skin , 1994, IEEE Transactions on Biomedical Engineering.

[34]  M J DAVIS,et al.  Electrical characteristics of the skin. The impedance of the surface sheath and deep tissues. , 1960, The Journal of investigative dermatology.

[35]  T. W. Coulter,et al.  Hazards in the use of low frequencies for the measurement of physiological events by impedance , 1969, Medical and biological engineering.

[36]  Akimasa Hirata,et al.  Synopsis of IEEE Std C95.1™-2019 “IEEE Standard for Safety Levels With Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz” , 2019, IEEE Access.

[37]  Fabio Freschi,et al.  Numerical Simulation of Heart-Current Factors and Electrical Models of the Human Body , 2012, IEEE Transactions on Industry Applications.

[38]  Effects of skeletal muscle anisotropy on induced currents from low-frequency magnetic fields. , 2009, Physics in medicine and biology.

[39]  Bora Boz,et al.  Hippocampal neuron loss due to electric injury in rats: a stereological study. , 2009, Legal medicine.

[40]  Mauro Feliziani,et al.  Assessment of Human Body Impedance for Safety Requirements Against Contact Currents for Frequencies up to 110 MHz , 2011, IEEE Transactions on Biomedical Engineering.

[41]  M A Stuchly,et al.  Effects of skeletal muscle anisotropy on human organ dosimetry under 60 Hz uniform magnetic field exposure. , 1998, Physics in medicine and biology.