Bio-mimetic Behaviour of IPMC Artificial Muscle Using EMG Signal

Assistive devices such as prosthetic and orthotic devices as well as micro robotic arm can perform similar operation of a human arm when these are actuated by muscle power. The generated force is transferred through an electro-mechanical system. Most of electro mechanical devices are heavy and are not compatible with muscular system. However, an ionic polymer metal composite (IPMC) has tremendous potential as an artificial muscle and is driven by a low voltage range between -3 to +3 V. In this paper, bio-mimetic actuation of IPMC is studied. The electric voltage is detected by electromyographic (EMG) signal through human muscle and is transferred to IPMC. It is observed that an IPMC shows similar behaviour and controls of a human fore arm.

[1]  Y. Cohen Electroactive Polymer (EAP) Actuators as Artificial Muscles - Reality , 2001 .

[2]  G. Cheron,et al.  A dynamic neural network identification of electromyography and arm trajectory relationship during complex movements , 1996, IEEE Transactions on Biomedical Engineering.

[3]  Suncheol Kwon,et al.  Real-time upper limb motion prediction from noninvasive biosignals for physical human-machine interactions , 2009, 2009 IEEE International Conference on Systems, Man and Cybernetics.

[4]  P A Parker,et al.  Operator performance in myoelectric control of a multifunction prosthesis stimulator. , 1990, Journal of rehabilitation research and development.

[5]  Peter M. Quesada,et al.  MUSCLE ACTIVITY AND THE QUANTIFICATION OF CO-CONTRACTION AT THE KNEE DURING WALKING GAIT , 2002 .

[6]  Y. Bar-Cohen Electroactive polymers as artificial muscles , 2007 .

[7]  Nissan Kunju,et al.  EMG Signal Analysis for Identifying Walking Patterns of Normal Healthy Individuals , 2009 .

[8]  Saravanan N Madras,et al.  Biosignal Based Human-Machine Interface for Robotic Arm , 2007 .

[9]  Yoseph Bar-Cohen,et al.  EDITORIAL: Focus issue on Biomimetics Using Electroactive Polymers as Artificial Muscles , 2007 .

[10]  Eugenio Orosco,et al.  Two-dimensional myoelectric control of a robotic arm for upper limb amputees , 2007 .

[11]  K. Kim,et al.  A novel method of manufacturing three-dimensional ionic polymer–metal composites (IPMCs) biomimetic sensors, actuators and artificial muscles , 2002 .

[12]  Kevin Englehart,et al.  A MICROPROCESSOR-BASED MULTIFUNCTION MYOELECTRIC CONTROL SYSTEM , 2000 .

[13]  Mu-Seong Mun,et al.  Control of IPMC-based Artificial Muscle for Myoelectric Hand Prosthesis , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[14]  C M Light,et al.  Intelligent multifunction myoelectric control of hand prostheses , 2002, Journal of medical engineering & technology.

[15]  Lena Maier-Hein,et al.  Articulatory Feature Classification using Surface Electromyography , 2006, 2006 IEEE International Conference on Acoustics Speech and Signal Processing Proceedings.

[16]  Yoseph Bar-Cohen,et al.  Electroactive Polymer (EAP) Actuators as Artificial Muscles: Reality, Potential, and Challenges, Second Edition , 2004 .

[17]  Sridhar P. Arjunan,et al.  Pattern classification of Myo-Electrical signal during different Maximum Voluntary Contractions: A study using BSS techniques , 2010 .

[18]  Brian Caulfield,et al.  MICRO ELECTRO MECHANICAL SYSTEMS BASED SENSOR FOR MECHANOMYOGRAPHY , 2008 .

[19]  Othman Omran Khalifa,et al.  EMG signal classification for human computer interaction: a review , 2009 .

[20]  M. Z. Al-Faiz,et al.  Human Arm Movements Recognition Based on EMG Signal , 2022 .