A Simple Adaptive Transfer Function for Deriving the Central Blood Pressure Waveform from a Radial Blood Pressure Waveform

Generalized transfer functions (GTFs) are available to compute the more relevant central blood pressure (BP) waveform from a more easily measured radial BP waveform. However, GTFs are population averages and therefore may not adapt to variations in pulse pressure (PP) amplification (ratio of radial to central PP). A simple adaptive transfer function (ATF) was developed. First, the transfer function is defined in terms of the wave travel time and reflection coefficient parameters of an arterial model. Then, the parameters are estimated from the radial BP waveform by exploiting the observation that central BP waveforms exhibit exponential diastolic decays. The ATF was assessed using the original data that helped popularize the GTF. These data included radial BP waveforms and invasive reference central BP waveforms from cardiac catheterization patients. The data were divided into low, middle, and high PP amplification groups. The ATF estimated central BP with greater accuracy than GTFs in the low PP amplification group (e.g., central systolic BP and PP root-mean-square-errors of 3.3 and 4.2 mm Hg versus 6.2 and 7.1 mm Hg; p ≤ 0.05) while showing similar accuracy in the higher PP amplification groups. The ATF may permit more accurate, non-invasive central BP monitoring in elderly and hypertensive patients.

[1]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[2]  T. Waddell,et al.  Carotid Pressure Is a Better Predictor of Coronary Artery Disease Severity Than Brachial Pressure , 2001, Hypertension.

[3]  A. Noordergraaf Circulatory System Dynamics , 1978 .

[4]  J. Blacher,et al.  Pulse pressure amplification, pressure waveform calibration and clinical applications. , 2012, Atherosclerosis.

[5]  W. Nichols,et al.  Comprar Mcdonald's blood flow in arteries. Theoretical, experimental and clinical principles | W. Nichols | 9780340985014 | Hodder Education , 2011 .

[6]  Riccardo Pini,et al.  Central but not brachial blood pressure predicts cardiovascular events in an unselected geriatric population: the ICARe Dicomano Study. , 2008, Journal of the American College of Cardiology.

[7]  The circulatory system , 1978 .

[8]  M. Malik,et al.  If Dr. Bazett Had Had a Computer… , 1996, Pacing and clinical electrophysiology : PACE.

[9]  Ramakrishna Mukkamala,et al.  Tube-Load Model Parameter Estimation for Monitoring Arterial Hemodynamics , 2011, Front. Physio..

[10]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[11]  Hao-Min Cheng,et al.  Quantification of the calibration error in the transfer function-derived central aortic blood pressures. , 2011, American journal of hypertension.

[12]  Hao-Min Cheng,et al.  Measurement accuracy of non-invasively obtained central blood pressure by applanation tonometry: a systematic review and meta-analysis. , 2013, International journal of cardiology.

[13]  Christodoulos Stefanadis,et al.  Prediction of cardiovascular events and all-cause mortality with central haemodynamics: a systematic review and meta-analysis. , 2010, European heart journal.

[14]  Gokul Swamy,et al.  An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveform. , 2009, American journal of physiology. Heart and circulatory physiology.

[15]  C. H. Chen,et al.  Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. , 1997, Circulation.

[16]  S. Holm A Simple Sequentially Rejective Multiple Test Procedure , 1979 .

[17]  H. Harry Asada,et al.  Subject-Specific Estimation of Central Aortic Blood Pressure Using an Individualized Transfer Function: A Preliminary Feasibility Study , 2012, IEEE Transactions on Information Technology in Biomedicine.

[18]  M. Bourgeois,et al.  Characteristics of Aortic Diastolic Pressure Decay with Application to the Continuous Monitoring of Changes in Peripheral Vascular Resistance , 1974, Circulation research.

[19]  M. Karamanoglu,et al.  An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. , 1993, European heart journal.

[20]  Ramakrishna Mukkamala,et al.  A comparative analysis of reduced arterial models for hemodynamic monitoring , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[21]  Ramakrishna Mukkamala,et al.  Patient-Specific Oscillometric Blood Pressure Measurement , 2016, IEEE Transactions on Biomedical Engineering.

[22]  K Sagawa,et al.  Translation of Otto Frank's paper "Die Grundform des Arteriellen Pulses" Zeitschrift für Biologie 37: 483-526 (1899). , 1990, Journal of molecular and cellular cardiology.

[23]  D. Kass,et al.  Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry , 1999, IEEE Transactions on Biomedical Engineering.