Design and Construction of the Optical Bench Interferometer for the Taiji Program

A kind of full-function two-sided optical bench interferometer (OBI) is designed to meet the practical requirements of the Taiji Program for space gravitational wave detection. The main optical paths are arranged on the A-side for transmission and interference, and other optical paths and electronic devices are placed on the B-side. According to the design scheme, we successfully constructed two OBIs by using hydrogen–oxygen catalytic stress-free bonding technology. When the OBI is installed and adjusted, the position and Angle error of the interference beam are controlled within 30 μm and 50 μrad through the self-designed precision mechanical clamping mechanism and beam position measuring device. The built OBI was placed on the vibration isolation platform in the vacuum tank for the stability test. The test results show that the noise of the OBI is less than 10 pm/√Hz in the frequency band of 0.1 Hz to 1 Hz, which meets the noise budget requirements of the Taiji Pathfinder in the middle- and high-frequency band.

[1]  A. Petiteau,et al.  Overview and progress on the Laser Interferometer Space Antenna mission , 2022, Nature Astronomy.

[2]  J. P. López-Zaragoza,et al.  Sensor noise in LISA Pathfinder : An extensive in-flight review of the angular and longitudinal interferometric measurement system , 2022, Physical Review D.

[3]  Gang Jin,et al.  Automatic, high-speed, high-precision acquisition scheme with QPD for the Taiji program. , 2020, Optics express.

[4]  Ziren Luo,et al.  The Taiji program: A concise overview , 2020 .

[5]  T. S. Schwarze,et al.  Optical Suppression of Tilt-to-Length Coupling in the LISA Long-Arm Interferometer , 2020, Physical Review Applied.

[6]  Salvatore J. Vitale,et al.  Beyond the Required LISA Free-Fall Performance: New LISA Pathfinder Results down to 20  μHz. , 2018, Physical review letters.

[7]  T. S. Schwarze,et al.  Design and construction of an optical test bed for LISA imaging systems and tilt-to-length coupling , 2016, 1607.00408.

[8]  A. Petiteau,et al.  Sub-Femto-g Free Fall for Space-Based Gravitational Wave Observatories: LISA Pathfinder Results. , 2016, Physical review letters.

[9]  B. A. Boom,et al.  Directly comparing GW150914 with numerical solutions of Einstein's equations for binary black hole coalescence , 2016, 1606.01262.

[10]  D. Reitze The Observation of Gravitational Waves from a Binary Black Hole Merger , 2016 .

[11]  L. W. Huff,et al.  The design and performance of the Gravity Probe B telescope , 2015 .

[12]  Christian J. Killow,et al.  Hydroxide catalysis bonding for astronomical instruments , 2014 .

[13]  Stefano Vitale,et al.  Space-borne gravitational wave observatories , 2014, 1404.3136.

[14]  A. M. Cruise,et al.  Construction and testing of the optical bench for LISA Pathfinder , 2013 .

[15]  J. Thorpe,et al.  Quasi-monolithic structures for spaceflight using hydroxide-catalysis bonding , 2012, IEEE Aerospace Conference.

[16]  A. Rüdiger,et al.  Orbit design for the Laser Interferometer Space Antenna (LISA) , 2010 .

[17]  Christian J. Killow,et al.  Hydroxide-catalysis bonding for stable optical systems for space , 2005 .

[18]  Ulrich Johann,et al.  The LTP interferometer and phasemeter , 2004 .

[19]  N. Beveridge Characterisation of silicon-silicon hydroxide catalysis bonds for future gravitational wave detectors , 2012 .