Sliding Mode Control System of Single Phase Buck-Boost Inverter with Buffer Inductor
暂无分享,去创建一个
Inverter is one of the primary components of a distributed electric power plants that serve as modifiers DC voltage into AC. In this research is applied of the Sliding Mode Control on Inverter Buck Boost One phase with Buffer Inductor. In the Open Loop test with the source voltage of 60 Volts, generate graphics output voltage in the form of a sinusoidal wave with maximum amplitude of about 400 volts. In the Closed Loop test, the graph output voltage can be controlled to follow a set point with SMC control method of order 2, and the resulting value Error Steady State smallest at 300 Volt, which amounted to 3.33%. The smallest sensitivity value of 0.29 when the input voltage changes by 32%.
[1] J. Ghaisari,et al. A new three-phase boost inverter: Topology and controller , 2008, 2008 Canadian Conference on Electrical and Computer Engineering.
[2] Handy Wicaksono,et al. Analisa Performansi dan Robustness Beberapa Metode Tuning Kontroler PID pada Motor DC , 2005 .
[3] Christopher Edwards,et al. Sliding Mode Control and Observation , 2013 .
[4] M. Purnomo,et al. A NEW TOPOLOGY OF THREE PHASE BUCK-BOOST INVERTER WITH BUFFER INDUCTOR , 2013 .