Door-opening motion can potentially lead to a transient breakdown in negative-pressure isolation conditions: the importance of vorticity and buoyancy airflows

Summary A patient with severe chickenpox was admitted to a negative-pressure isolation room. He remained sedated, intubated and mechanically ventilated throughout his admission. He was managed only by nurses immune to chickenpox. A non-immune male nurse occasionally handed equipment through the doorway, without entering the room. Ten days later, he also developed chickenpox. Sequencing of viruses from the patient and nurse showed the same rare genotype, indicating nosocomial transmission. An experimental model demonstrated that, despite negative pressure, opening the door could have resulted in transport of infectious air out of the isolation room, leading to a breakdown in isolation conditions.

[1]  Tze Wai Wong,et al.  Evidence of airborne transmission of the severe acute respiratory syndrome virus. , 2004, The New England journal of medicine.

[2]  G. Batchelor,et al.  An Introduction to Fluid Dynamics , 1968 .

[3]  D. Goldmann,et al.  Airborne transmission of chickenpox in a hospital. , 1980, The New England journal of medicine.

[4]  M. Wallace,et al.  Detection of varicella-zoster virus DNA in air samples from hospital rooms. , 1994, The Journal of infectious diseases.

[5]  J. Bartley,et al.  New ventilation Guidelines for health-care facilities , 2001 .

[6]  I. Orme,et al.  Cough-generated aerosols of Mycobacterium tuberculosis: a new method to study infectiousness. , 2004, American journal of respiratory and critical care medicine.

[7]  David Satcher,et al.  Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care facilities, 1994. Centers for Disease Control and Prevention. , 1994, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.