A low cost wearable optical-based goniometer for human joint monitoring

Widely used in the fields of physical and occupational therapy, goniometers are indispensible when it comes to angular measurement of the human joint. In both fields, there is a need to measure the range of motion associated with various joints and muscle groups. For example, a goniometer may be used to help determine the current status of the range of motion in bend the arm at the elbow, bending the knee, or bending at the waist. The device can help to establish the range of motion at the beginning of the treatment series, and also allow the therapist to monitor progress during subsequent sessions. Most commonly found are the mechanical goniometers which are inexpensive but bulky. As the parts are mechanically linked, accuracy and resolution are largely limited. On the other hand, electronic and optical fiberbased goniometers promise better performance over its mechanical counterpart but due to higher cost and setup requirements does not make it an attractive proposition as well. In this paper, we present a reliable and non-intrusive design of an optical-based goniometer for human joint measurement. This device will allow continuous and longterm monitoring of human joint motion in everyday setting. The proposed device was benchmarked against mechanical goniometer and optical based motion capture system to validate its performance. From the empirical results, it has been proven that this design can be use as a robust and effective wearable joint monitoring device.

[1]  Elia Palange,et al.  A New Flexible Optical Fiber Goniometer for Dynamic Angular Measurements: Application to Human Joint Movement Monitoring , 2008, IEEE Transactions on Instrumentation and Measurement.

[2]  T. W. Ng,et al.  The optical mouse for vibratory motion sensing , 2004 .

[3]  B. Steele,et al.  Bodies in motion: monitoring daily activity and exercise with motion sensors in people with chronic pulmonary disease. , 2003, Journal of rehabilitation research and development.

[4]  F K Fuss,et al.  The ulnar collateral ligament of the human elbow joint. Anatomy, function and biomechanics. , 1991, Journal of anatomy.

[5]  H Harry Asada,et al.  Wearable Conductive Fiber Sensors for Multi-Axis Human Joint Angle Measurements , 2005, Journal of NeuroEngineering and Rehabilitation.

[6]  Angela Shiratsu,et al.  Reliability and accuracy of different sensors of a flexible electrogoniometer. , 2003, Clinical biomechanics.

[7]  Marcel Tresanchez,et al.  Using the image acquisition capabilities of the optical mouse sensor to build an absolute rotary encoder , 2010 .

[8]  Bernard F. Morrey,et al.  The Elbow and Its Disorders , 2000 .

[9]  P.H. Veltink,et al.  Inclination measurement of human movement using a 3-D accelerometer with autocalibration , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[10]  D. J. White,et al.  Measurement Of Joint Motion A Guide To Goniometry , 2016 .

[11]  Umberto Minoni,et al.  Low-cost optical motion sensors: An experimental characterization , 2006 .

[12]  Vladimir M. Zatsiorsky,et al.  Kinetics of Human Motion , 2002 .

[13]  B Zappa,et al.  A model of an electro-goniometer and its calibration for biomechanical applications. , 2000, Medical engineering & physics.

[14]  Jordi Palacín,et al.  The optical mouse for indoor mobile robot odometry measurement , 2006 .

[15]  P H Veltink,et al.  Detection of static and dynamic activities using uniaxial accelerometers. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[16]  William D. Bandy,et al.  Joint Range of Motion and Muscle Length Testing , 2009 .