A continuous-flow capillary mixing method to monitor reactions on the microsecond time scale.

A continuous-flow capillary mixing apparatus, based on the original design of Regenfuss et al. (Regenfuss, P., R. M. Clegg, M. J. Fulwyler, F. J. Barrantes, and T. M. Jovin. 1985. Rev. Sci. Instrum. 56:283-290), has been developed with significant advances in mixer design, detection method and data analysis. To overcome the problems associated with the free-flowing jet used for observation in the original design (instability, optical artifacts due to scattering, poor definition of the geometry), the solution emerging from the capillary is injected directly into a flow-cell joined to the tip of the outer capillary via a ground-glass joint. The reaction kinetics are followed by measuring fluorescence versus distance downstream from the mixer, using an Hg(Xe) arc lamp for excitation and a digital camera with a UV-sensitized CCD detector for detection. Test reactions involving fluorescent dyes indicate that mixing is completed within 15 micros of its initiation and that the dead time of the measurement is 45 +/- 5 micros, which represents a >30-fold improvement in time resolution over conventional stopped-flow instruments. The high sensitivity and linearity of the CCD camera have been instrumental in obtaining artifact-free kinetic data over the time window from approximately 45 micros to a few milliseconds with signal-to-noise levels comparable to those of conventional methods. The scope of the method is discussed and illustrated with an example of a protein folding reaction.

[1]  S. Walter Englander,et al.  Structural characterization of folding intermediates in cytochrome c by H-exchange labelling and proton NMR , 1988, Nature.

[2]  D. Brems,et al.  Manipulation of the observed kinetic phases in the refolding of denatured ferricytochromes c. , 1983, The Journal of biological chemistry.

[3]  J. M. Pratt,et al.  Hemes and hemoproteins. 1: Preparation and analysis of the heme-containing octapeptide (microperoxidase-8) and identification of the monomeric form in aqueous solution. , 1986, Journal of inorganic biochemistry.

[4]  B. Balko,et al.  High speed optical stopped-flow apparatus. , 1968, The Review of scientific instruments.

[5]  David S. Gottfried,et al.  Folding of cytochrome c initiated by submillisecond mixing , 1997, Nature Structural Biology.

[6]  M. J. Parker,et al.  An integrated kinetic analysis of intermediates and transition states in protein folding reactions. , 1995, Journal of molecular biology.

[7]  Britton Chance,et al.  The accelerated flow method for rapid reactions , 1940 .

[8]  Multicapillary Mixer of Solutions , 1966, Science.

[9]  S Sugai,et al.  Rapid formation of secondary structure framework in protein folding studied by stopped‐flow circular dichroism , 1987, FEBS letters.

[10]  C M Dobson,et al.  Collapse and cooperativity in protein folding. , 1996, Current opinion in structural biology.

[11]  B Balko,et al.  High resolution mixer for the study of the kinetics of rapid reactions in solution. , 1968, The Review of scientific instruments.

[12]  B F Peterman,et al.  Measurement of the dead time of a fluorescence stopped-flow instrument. , 1979, Analytical biochemistry.

[13]  T. Sosnick,et al.  Molecular collapse: The rate‐limiting step in two‐state cytochrome c folding , 1996, Proteins.

[14]  H. Hartridge,et al.  A method of measuring the velocity of very rapid chemical reactions , 1923 .

[15]  J. Hofrichter,et al.  Submillisecond protein folding kinetics studied by ultrarapid mixing. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[16]  T. Tsong Ferricytochrome c chain folding measured by the energy transfer of tryptophan 59 to the heme group. , 1976, Biochemistry.

[17]  D. Ballou,et al.  Determination of the dead time of a stopped-flow fluorometer. , 1989, Analytical biochemistry.

[18]  Time-resolved resonance Raman spectroscopy using a fast mixing device , 1994 .

[19]  S. Khorasanizadeh,et al.  Evidence for a three-state model of protein folding from kinetic analysis of ubiquitin variants with altered core residues , 1996, Nature Structural Biology.

[20]  H. Roder Structural characterization of protein folding intermediates by proton magnetic resonance and hydrogen exchange. , 1989, Methods in enzymology.

[21]  H. Roder,et al.  Kinetic role of early intermediates in protein folding. , 1997, Current opinion in structural biology.

[22]  F Sherman,et al.  Side chain packing of the N- and C-terminal helices plays a critical role in the kinetics of cytochrome c folding. , 1996, Biochemistry.

[23]  D. Rousseau,et al.  Microsecond Generation of Oxygen-bound Cytochrome c Oxidase by Rapid Solution Mixing (*) , 1995, The Journal of Biological Chemistry.

[24]  Matthews Cr PATHWAYS OF PROTEIN FOLDING , 1993 .

[25]  Q H Gibson,et al.  Apparatus for rapid and sensitive spectrophotometry. , 1964, The Biochemical journal.

[26]  A. Chaffotte,et al.  Early steps in cytochrome c folding probed by time-resolved circular dichroism and fluorescence spectroscopy. , 1992, Biochemistry.

[27]  T. Sosnick,et al.  The barriers in protein folding , 1994, Nature Structural Biology.

[28]  O. Ptitsyn Structures of folding intermediates. , 1995, Current opinion in structural biology.

[29]  A. Fersht Enzyme structure and mechanism , 1977 .

[30]  P. S. Kim,et al.  Intermediates in the folding reactions of small proteins. , 1990, Annual review of biochemistry.

[31]  J. M. Sauder,et al.  Kinetic mechanism of folding and unfolding of Rhodobacter capsulatus cytochrome c2. , 1996, Biochemistry.

[32]  H. Roder,et al.  An early intermediate in the folding reaction of the B1 domain of protein G contains a native-like core. , 1997, Biochemistry.

[33]  C. M. Jones,et al.  Fast events in protein folding initiated by nanosecond laser photolysis. , 1993, Proceedings of the National Academy of Sciences of the United States of America.

[34]  K. Kuwajima,et al.  Characterization of the critical state in protein folding. Effects of guanidine hydrochloride and specific Ca2+ binding on the folding kinetics of alpha-lactalbumin. , 1989, Journal of molecular biology.

[35]  A. Bhuyan,et al.  Kinetic mechanism of cytochrome c folding: involvement of the heme and its ligands. , 1994, Biochemistry.

[36]  K. Kirschner,et al.  Calibration of stopped-flow spectrophotometers using a two-step disulfide exchange reaction. , 1980, Analytical biochemistry.

[37]  Mixing liquids in microseconds , 1985 .