Chip Based Electroanalytical Systems for Cell Analysis

This review with 239 references has as its aim to give the reader an introduction to the kinds of methods used for developing microchip based electrode systems as well as to cover the existing literature on electroanalytical systems where microchips play a crucial role for “none-destructive” measurements of processes related to living cells, i.e., systems without lysing the cells. The focus is on chip based amperometric and impedimetric cell analysis systems where measurements utilizing solely carbon fibre microelectrodes (CFME) and other non-chip electrode formats, such as CFME for exocytosis studies and scanning electrochemical microscopy (SECM) studies of living cells have been omitted. Included is also a discussion about some future and emerging nano tools and considerations that might have an impact on the future of “non-destructive” chip based electroanalysis of living cells. (Less)

[1]  V. Antony,et al.  Th2 Cytokines IL-4 and IL-13 Downregulate Paxillin Expression in Bronchial Airway Epithelial Cells , 2004, Journal of Clinical Immunology.

[2]  Bernard Lachance,et al.  An in-depth analysis of electric cell-substrate impedance sensing to study the attachment and spreading of mammalian cells. , 2002, Analytical chemistry.

[3]  I. Giaever,et al.  Effect of the pSV2-neo plasmid on NIH 3T3 cell motion detected electrically. , 1994, Experimental cell research.

[4]  R. Wightman,et al.  Dopamine transport into a single cell in a picoliter vial. , 2002, Analytical chemistry.

[5]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[6]  M. E. Charness,et al.  Antagonists of alcohol inhibition of cell adhesion. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[7]  A. Niendorf,et al.  Microphysiological testing for chemosensitivity of living tumor cells with multiparametric microsensor chips. , 2003, Cancer detection and prevention.

[8]  A. Folch,et al.  Biology on a chip: microfabrication for studying the behavior of cultured cells. , 2003, Critical reviews in biomedical engineering.

[9]  Diego Krapf,et al.  Mesoscopic concentration fluctuations in a fluidic nanocavity detected by redox cycling. , 2007, Nano letters.

[10]  K. Torimitsu,et al.  Improvement in signal reliability when measuring l-glutamate released from cultured cells using multi-channel microfabricated sensors , 2001 .

[11]  C. Lo,et al.  Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing. , 1995, Biophysical journal.

[12]  J. A. Jankowski,et al.  Temporally resolved catecholamine spikes correspond to single vesicle release from individual chromaffin cells. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[13]  Wei Zheng,et al.  Application of real-time cell electronic sensing (RT-CES) technology to cell-based assays. , 2004, Assay and drug development technologies.

[14]  S. Rotenberg,et al.  Scanning electrochemical microscopy of living cells: different redox activities of nonmetastatic and metastatic human breast cells. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[15]  K. Foster,et al.  Dielectric properties of tissues and biological materials: a critical review. , 1989, Critical reviews in biomedical engineering.

[16]  Dmitri B Papkovsky,et al.  The use of a fluorescence-based oxygen uptake assay in the analysis of cytotoxicity. , 2006, Toxicology in vitro : an international journal published in association with BIBRA.

[17]  C. McNeil,et al.  Sensor-based measurements of the role and interactions of free radicals in cellular systems. , 2002, Journal of biotechnology.

[18]  A. König,et al.  Multimicrobial sensor using microstructured three-dimensional electrodes based on silicon technology. , 2000, Analytical chemistry.

[19]  Viktor Malyarchuk,et al.  High performance plasmonic crystal sensor formed by soft nanoimprint lithography. , 2005, Optics express.

[20]  Tomoyuki Yasukawa,et al.  Electrochemical mutagen screening using microbial chip. , 2006, Biosensors & bioelectronics.

[21]  K. Torimitsu,et al.  Continuous Monitoring of L‐Glutamate Released from Cultured Rat Nerve Cells with a Microfabricated On‐Line Sensor at a Slow Flow Rate , 1999 .

[22]  W. H. van der Schalie,et al.  Selection of a battery of rapid toxicity sensors for drinking water evaluation. , 2006, Biosensors & bioelectronics.

[23]  W. Schuhmann,et al.  Integrated compact biocompatible hydrogel-based amperometric sensing device for easy screening of drugs involved in nitric oxide production by adherent cultured cells , 2005 .

[24]  S. Gawad,et al.  Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. , 2001, Lab on a chip.

[25]  P. Smith,et al.  Development of self-referencing oxygen microsensor and its application to single pancreatic HIT cells: effects of adenylate cyclase activator forskolin on oxygen consumption. , 2000, The Biological bulletin.

[26]  D. Lawrence,et al.  Measurement of macrophage adherence and spreading with weak electric fields. , 1990, Journal of immunological methods.

[27]  S A Chan,et al.  Physiological stimuli evoke two forms of endocytosis in bovine chromaffin cells , 2001, The Journal of physiology.

[28]  A. Guiseppi-Elie,et al.  Improving neuron-to-electrode surface attachment via alkanethiol self-assembly: an alternating current impedance study. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[29]  R. McGuinness,et al.  Cellular Dielectric Spectroscopy: A Powerful New Approach to Label-Free Cellular Analysis , 2004, Journal of biomolecular screening.

[30]  Tomoyuki Yasukawa,et al.  Fabrication of miniature Clark oxygen sensor integrated with microstructure , 2005 .

[31]  I. Giaever,et al.  Monitoring electropermeabilization in the plasma membrane of adherent mammalian cells. , 1993, Biophysical journal.

[32]  C. Lo,et al.  pH changes in pulsed CO2 incubators cause periodic changes in cell morphology. , 1994, Experimental cell research.

[33]  S. Gawad,et al.  Impedance spectroscopy flow cytometry: On‐chip label‐free cell differentiation , 2005, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[34]  A. Bard,et al.  Menadione metabolism to thiodione in hepatoblastoma by scanning electrochemical microscopy. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[35]  V. Rumjanek,et al.  Mediators of cellular immune reactions. , 1982, Pharmacology & therapeutics.

[36]  K. Dick,et al.  Directed Growth of Branched Nanowire Structures , 2007 .

[37]  Bernard Lachance,et al.  Assessment of cytotoxicity using electric cell-substrate impedance sensing: concentration and time response function approach. , 2002, Analytical chemistry.

[38]  Yasuo Ogasawara,et al.  Measurements of endothelial cell-to-cell and cell-to-substrate gaps and micromechanical properties of endothelial cells during monocyte adhesion , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[39]  A. Benabid,et al.  Alteration of hormone and neurotransmitter production in cultured cells by high and low frequency electrical stimulation , 2006, Acta Neurochirurgica.

[40]  Fwu-Shan Sheu,et al.  In situ temporal detection of dopamine exocytosis from L-dopa-incubated MN9D cells using microelectrode array-integrated biochip , 2006 .

[41]  Khajak Berberian,et al.  Electrochemical imaging of fusion pore openings by electrochemical detector arrays. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[42]  A. Ewing,et al.  Voltammetric measurement of oxygen in single neurons using platinized carbon ring electrodes. , 1992, Analytical chemistry.

[43]  Wei-Hua Huang,et al.  Transport, location, and quantal release monitoring of single cells on a microfluidic device. , 2004, Analytical chemistry.

[44]  G. R. Facer,et al.  Capacitance cytometry: measuring biological cells one by one. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[45]  W. Schuhmann,et al.  Redox hydrogel-based bienzyme microelectrodes for amperometric monitoring of L-glutamate , 2002 .

[46]  Seung-Cheol Chang,et al.  Simultaneous intra- and extracellular superoxide monitoring using an integrated optical and electrochemical sensor system. , 2005, Biochemical and biophysical research communications.

[47]  F. Hafner,et al.  Cytosensor Microphysiometer: technology and recent applications. , 2000, Biosensors & bioelectronics.

[48]  Jenny Zhu,et al.  Dynamic Monitoring of Cell Adhesion and Spreading on Microelectronic Sensor Arrays , 2005, Journal of biomolecular screening.

[49]  D. Janigro,et al.  Alternating current electrical stimulation enhanced chemotherapy: a novel strategy to bypass multidrug resistance in tumor cells , 2006, BMC Cancer.

[50]  M. Glogauer,et al.  Cell-substrate separation: effect of applied force and temperature , 1998, European Biophysics Journal.

[51]  Meinhard Knoll,et al.  An amperometric microsensor array with 1024 individually addressable elements for two-dimensional concentration mapping , 1994 .

[52]  Hua Zhang,et al.  Fabrication of Microelectrode Arrays Using Microcontact Printing , 2000 .

[53]  Ronald Pethig,et al.  Dielectric and electronic properties of biological materials , 1979 .

[54]  E. Gheorghiu,et al.  Real-time monitoring of yeast cell division by dielectric spectroscopy. , 1999, Biophysical journal.

[55]  Joachim Wegener,et al.  Bioelectrical impedance assay to monitor changes in cell shape during apoptosis. , 2004, Biosensors & bioelectronics.

[56]  R. S. Kelly,et al.  Bevelled carbon-fiber ultramicroelectrodes , 1986 .

[57]  Ivar Giaever,et al.  Electrical Impedance of Cultured Endothelium Under Fluid Flow , 2001, Annals of Biomedical Engineering.

[58]  I. Giaever,et al.  Monitoring fibroblast behavior in tissue culture with an applied electric field. , 1984, Proceedings of the National Academy of Sciences of the United States of America.

[59]  H. Shiku,et al.  Cytokine assay on a cellular chip by combining collagen gel embedded culture with scanning electrochemical microscopy , 2006 .

[60]  J. K. Lumpp,et al.  Microfabrication of screen-printed nanoliter vials with embedded surface-modified electrodes , 2006, Analytical and bioanalytical chemistry.

[61]  H. Galla,et al.  Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces. , 1996, Journal of biochemical and biophysical methods.

[62]  Isao Karube,et al.  An integrated module for sensing pO2, pCO2, and pH , 2000 .

[63]  B Wolf,et al.  Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures. , 1997, Biosensors & bioelectronics.

[64]  B. Olde,et al.  A chimeric reporter gene allowing for clone selection and high-throughput screening of reporter cell lines expressing G-protein-coupled receptors. , 2001, Analytical biochemistry.

[65]  Jaime Castillo,et al.  Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate. , 2005, Biosensors & bioelectronics.

[66]  B Wolf,et al.  Multiparametric microsensor chips for screening applications , 2001, Fresenius' journal of analytical chemistry.

[67]  Alan Hall,et al.  Rho GTPases: biochemistry and biology. , 2005, Annual review of cell and developmental biology.

[68]  Weihua Huang,et al.  Carbon fiber nanoelectrodes applied to microchip electrophoresis amperometric detection of neurotransmitter dopamine in rat pheochromocytoma (PC12) cells , 2007, Electrophoresis.

[69]  G. Woude,et al.  Overexpression of sprouty 2 inhibits HGF/SF-mediated cell growth, invasion, migration, and cytokinesis , 2004, Oncogene.

[70]  Monica Simion,et al.  Development of the micro- and nanoelectrodes for cells investigation , 2007 .

[71]  Michihiko Yoshida,et al.  A Novel Integrin-Linked Kinase–Binding Protein, Affixin, Is Involved in the Early Stage of Cell–Substrate Interaction , 2001, The Journal of cell biology.

[72]  Bo Mattiasson,et al.  Amine Oxidase Based Amperometric Biosensors forHistamine Detection , 2000 .

[73]  George M. Whitesides,et al.  Microfabrication by microcontact printing of self‐assembled monolayers , 1994 .

[74]  Xueji Zhang,et al.  A Novel Microchip Nitric Oxide Sensor with sub‐nM Detection Limit , 2002 .

[75]  Chun-Min Lo,et al.  Claudin-4 overexpression in epithelial ovarian cancer is associated with hypomethylation and is a potential target for modulation of tight junction barrier function using a C-terminal fragment of Clostridium perfringens enterotoxin. , 2007, Neoplasia.

[76]  Peidong Yang,et al.  Interfacing silicon nanowires with mammalian cells. , 2007, Journal of the American Chemical Society.

[77]  Yuji Kikuchi,et al.  Determination of blood pO2 using a micromachined Clark-type oxygen electrode , 2001 .

[78]  T. Hug,et al.  Biophysical methods for monitoring cell-substrate interactions in drug discovery. , 2003, Assay and drug development technologies.

[79]  Ron C. Hardman A Toxicologic Review of Quantum Dots: Toxicity Depends on Physicochemical and Environmental Factors , 2005, Environmental health perspectives.

[80]  Koji Asami,et al.  Characterization of biological cells by dielectric spectroscopy , 2002 .

[81]  S I Simon,et al.  Analysis of tight junctions during neutrophil transendothelial migration. , 2000, Journal of cell science.

[82]  C. Olanow A radical hypothesis for neurodegeneration , 1993, Trends in Neurosciences.

[83]  Yen-Wen Chen,et al.  Cellular dielectric spectroscopy: a label-free comprehensive platform for functional evaluation of endogenous receptors. , 2006, Assay and drug development technologies.

[84]  Matsuhiko Nishizawa,et al.  Micropatterning of HeLa Cells on Glass Substrates and Evaluation of Respiratory Activity Using Microelectrodes , 2002 .

[85]  Peter Fromherz,et al.  A cell-semiconductor synapse: transistor recording of vesicle release in chromaffin cells. , 2007, Biophysical journal.

[86]  A. Malik,et al.  Electrical method for detection of endothelial cell shape change in real time: assessment of endothelial barrier function. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[87]  Brian J. Birch,et al.  Development of screen-printed carbon electrodes, chemically modified with cobalt phthalocyanine, for electrochemical sensor applications , 1990 .

[88]  Richard H. P. Porter,et al.  Glutamate and Parkinson’s disease , 1996, Molecular Neurobiology.

[89]  G. Reibnegger,et al.  Monoaminergic neurotransmitters, their precursors and metabolites in brains of Alzheimer patients , 1996, Neuroscience Letters.

[90]  Owe Orwar,et al.  Artificial cells: Unique insights into exocytosis using liposomes and lipid nanotubes , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[91]  Chun-Min Lo,et al.  Impedance analysis of fibroblastic cell layers measured by electric cell-substrate impedance sensing , 1998 .

[92]  Xiao Xu,et al.  Live cell quality control and utility of real-time cell electronic sensing for assay development. , 2006, Assay and drug development technologies.

[93]  J. Cooper,et al.  Nanofabrication of electrode arrays by electron-beam and nanoimprint lithographies. , 2006, Lab on a chip.

[94]  Matsuhiko Nishizawa,et al.  Scanning electrochemical microscopy-based drug sensitivity test for a cell culture integrated in silicon microstructures. , 2003, Analytical chemistry.

[95]  I. Giaever,et al.  Micromotion of mammalian cells measured electrically. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[96]  G. Kovacs Micromachined Transducers Sourcebook , 1998 .

[97]  J. W. Schultze,et al.  Principles of electrochemical micro- and nano-system technologies , 2001 .

[98]  A. Bard,et al.  Scanning electrochemical microscopy of menadione-glutathione conjugate export from yeast cells. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[99]  Gerald Urban,et al.  A miniaturized amperometric CO2 sensor based on dissociation of copper complexes , 2003 .

[100]  John H T Luong,et al.  On‐Line Monitoring of Cell Growth and Cytotoxicity Using Electric Cell‐Substrate Impedance Sensing (ECIS) , 2003, Biotechnology progress.

[101]  T. Matsue,et al.  Characterization and Imaging of Single Cells with Scanning Electrochemical Microscopy , 2000 .

[102]  A. Hansen,et al.  Dynamic detection of natural killer cell-mediated cytotoxicity and cell adhesion by electrical impedance measurements. , 2006, Assay and drug development technologies.

[103]  Ivar Giaever,et al.  Use of Electric Fields to Monitor the Dynamical Aspect of Cell Behavior in Tissue Culture , 1986, IEEE Transactions on Biomedical Engineering.

[104]  M. White,et al.  Coordination of cell death and the cell cycle: linking proliferation to death through private and communal couplers. , 2004, Current opinion in cell biology.

[105]  Colette McDonagh,et al.  Plasmonic enhancement of fluorescence for sensor applications , 2005 .

[106]  D. Kültz,et al.  Evolution of the cellular stress proteome: from monophyletic origin to ubiquitous function , 2003, Journal of Experimental Biology.

[107]  J. Oni,et al.  Functionalised electrode array for the detection of nitric oxide released by endothelial cells using different NO-sensing chemistries , 2004, Analytical and bioanalytical chemistry.

[108]  A. B. Frazier,et al.  Microsystems for isolation and electrophysiological analysis of breast cancer cells from blood. , 2006, Biosensors & bioelectronics.

[109]  Xiao Xu,et al.  Real-time monitoring of morphological changes in living cells by electronic cell sensor arrays: an approach to study G protein-coupled receptors. , 2006, Analytical chemistry.

[110]  K. Torimitsu,et al.  Continuous measurement of histamine from rat basophilic leukemia cells (RBL-2H3) with an on-line sensor using histamine oxidase , 2000 .

[111]  Didier Merlin,et al.  Concomitant activation of the JAK/STAT, PI3K/AKT, and ERK signaling is involved in leptin-mediated promotion of invasion and migration of hepatocellular carcinoma cells. , 2007, Cancer research.

[112]  K. Torimitsu,et al.  Continuous Measurement of Glutamate and Hydrogen Peroxide Using a Microfabricated Biosensor for Studying the Neurotoxicity of Tributyltin , 2003, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[113]  E. Bieberich,et al.  Neuronal differentiation and synapse formation of PC12 and embryonic stem cells on interdigitated microelectrode arrays: contact structures for neuron-to-electrode signal transmission (NEST). , 2004, Biosensors & bioelectronics.

[114]  D. Postma,et al.  Down-Regulation of E-Cadherin in Human Bronchial Epithelial Cells Leads to Epidermal Growth Factor Receptor-Dependent Th2 Cell-Promoting Activity1 , 2007, The Journal of Immunology.

[115]  R. Wightman Probing Cellular Chemistry in Biological Systems with Microelectrodes , 2006, Science.

[116]  Kenji Yokoyama,et al.  Integration of enzyme-immobilized column with electrochemical flow cell using micromachining techniques for a glucose detection system , 1993 .

[117]  Stephan Gabos,et al.  Dynamic monitoring of cytotoxicity on microelectronic sensors. , 2005, Chemical research in toxicology.

[118]  Joachim Wegener,et al.  The impact of glia-derived extracellular matrices on the barrier function of cerebral endothelial cells: an in vitro study. , 2007, Experimental cell research.

[119]  Yosi Shacham-Diamand,et al.  Novel integrated electrochemical nano-biochip for toxicity detection in water. , 2005, Nano letters.

[120]  J. Ye,et al.  Fabrication and electrochemical characterization of interdigitated nanoelectrode arrays , 2005 .

[121]  R. Hoffman,et al.  Flow-system measurement of cell impedance properties. , 1979, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[122]  Tsutomu Horiuchi,et al.  Selective detection of L-glutamate using a microfluidic device integrated with an enzyme-modified pre-reactor and an electrochemical detector. , 2003, Biosensors & bioelectronics.

[123]  K. Kihm,et al.  An endothelial cell compatible biosensor fabricated using optically thin indium tin oxide silicon nitride electrodes. , 2007, Biosensors & bioelectronics.

[124]  M. Koudelka-Hep,et al.  Amperometric monitoring of redox activity in living yeast cells: comparison of menadione and menadione sodium bisulfite as electron transfer mediators , 2004 .

[125]  Pascal Colpo,et al.  Assessment of cytotoxicity by impedance spectroscopy. , 2007, Biosensors & bioelectronics.

[126]  D E Ingber,et al.  Using microcontact printing to pattern the attachment of mammalian cells to self-assembled monolayers of alkanethiolates on transparent films of gold and silver. , 1997, Experimental cell research.

[127]  Matsuhiko Nishizawa,et al.  Multi-channel 3-D cell culture device integrated on a silicon chip for anticancer drug sensitivity test. , 2005, Biomaterials.

[128]  I. Giaever,et al.  Prostaglandin E2 alters human orbital fibroblast shape through a mechanism involving the generation of cyclic adenosine monophosphate. , 1995, The Journal of clinical endocrinology and metabolism.

[129]  D. Kell,et al.  The passive electrical properties of biological systems: their significance in physiology, biophysics and biotechnology. , 1987, Physics in medicine and biology.

[130]  Dana M Spence,et al.  Amperometric determination of nitric oxide derived from pulmonary artery endothelial cells immobilized in a microchip channel. , 2004, The Analyst.

[131]  Helene Andersson,et al.  Microtechnologies and nanotechnologies for single-cell analysis. , 2004, Current opinion in biotechnology.

[132]  J. Castracane,et al.  Amperometric detection of quantal catecholamine secretion from individual cells on micromachined silicon chips. , 2003, Analytical chemistry.

[133]  S Fiorito,et al.  Toxicity and biocompatibility of carbon nanoparticles. , 2006, Journal of nanoscience and nanotechnology.

[134]  Fwu-Shan Sheu,et al.  Microelectrode array biochip: tool for in vitro drug screening based on the detection of a drug effect on dopamine release from PC12 cells. , 2006, Analytical chemistry.

[135]  K. Kim,et al.  Human astrocytes/astrocyte-conditioned medium and shear stress enhance the barrier properties of human brain microvascular endothelial cells , 2007, Brain Research.

[136]  E Neher,et al.  Discrete changes of cell membrane capacitance observed under conditions of enhanced secretion in bovine adrenal chromaffin cells. , 1982, Proceedings of the National Academy of Sciences of the United States of America.

[137]  Arto Heiskanen,et al.  On-Chip Determination of Dopamine Exocytosis Using Mercaptopropionic Acid Modified Microelectrodes , 2007 .

[138]  John H T Luong,et al.  Assessment of cytotoxicity by emerging impedance spectroscopy. , 2005, Toxicology and applied pharmacology.

[139]  Christine Williams,et al.  Patch clamping by numbers. , 2004, Drug discovery today.

[140]  Margit Zacharias,et al.  Semiconductor nanowires: from self-organization to patterned growth. , 2006, Small.

[141]  A. Ewing,et al.  Estimation of Free Dopamine in the Cytoplasm of the Giant Dopamine Cell of Planorbis corneus by Voltammetry and Capillary Electrophoresis , 1990, Journal of neurochemistry.

[142]  J. Luong,et al.  Extended applications of electric cell-substrate impedance sensing for assessment of the structure-function of α2β1 integrin , 2004 .

[143]  A. Ewing,et al.  Observation and quantitation of exocytosis from the cell body of a fully developed neuron in Planorbis corneus , 1995, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[144]  Xiao Xu,et al.  Dynamic and label-free monitoring of natural killer cell cytotoxic activity using electronic cell sensor arrays. , 2006, Journal of immunological methods.

[145]  P. Osborne,et al.  Concentration of extracellular L-glutamate released from cultured nerve cells measured with a small-volume online sensor. , 1996, Analytical chemistry.

[146]  J. Coyle,et al.  The emerging role of glutamate in the pathophysiology and treatment of schizophrenia. , 2001, The American journal of psychiatry.

[147]  J M Cooper,et al.  Single-cell measurements of purine release using a micromachined electroanalytical sensor. , 1998, Analytical chemistry.

[148]  J. Bodmer,et al.  Histamine and thrombin modulate endothelial focal adhesion through centripetal and centrifugal forces. , 1996, The Journal of clinical investigation.

[149]  M. Madou Fundamentals of microfabrication : the science of miniaturization , 2002 .

[150]  G Jobst,et al.  Miniaturized thin film glutamate and glutamine biosensors. , 1995, Biosensors & bioelectronics.

[151]  Li Xie,et al.  Microelectronic cell sensor assay for detection of cytotoxicity and prediction of acute toxicity. , 2006, Toxicology in vitro : an international journal published in association with BIBRA.

[152]  L. Berdondini,et al.  Cell-compatible array of three-dimensional tip electrodes for the detection of nitric oxide release. , 2005, Biosensors & bioelectronics.

[153]  Richard D. Rabbitt,et al.  Electric impedance spectroscopy using microchannels with integrated metal electrodes , 1999 .

[154]  Eunjeong Lee An integrated system of microcantilever arrays with carbon nanotube tips for imaging, sensing, and 3D nanomanipulation: Design and control , 2007 .

[155]  A. B. Frazier,et al.  Ion channel characterization using single cell impedance spectroscopy. , 2006, Lab on a chip.

[156]  Joachim Wegener,et al.  Recovery of adherent cells after in situ electroporation monitored electrically. , 2002, BioTechniques.

[157]  Guonan Chen,et al.  Enhanced electrochemical performance at screen-printed carbon electrodes by a new pretreating procedure. , 2007, Analytica chimica acta.

[158]  Joachim Wegener,et al.  Use of electrochemical impedance measurements to monitor β-adrenergic stimulation of bovine aortic endothelial cells , 1999, Pflügers Archiv.

[159]  M. Watsky,et al.  LPA and S1P increase corneal epithelial and endothelial cell transcellular resistance. , 2005, Investigative ophthalmology & visual science.

[160]  K. Torimitsu,et al.  Continuous monitoring of L-glutamate released from cultured nerve cells by an online sensor coupled with micro-capillary sampling. , 1997, Biosensors & bioelectronics.

[161]  James R. Henderson,et al.  An electrochemical sensor array system for the direct, simultaneous in vitro monitoring of nitric oxide and superoxide production by cultured cells. , 2005, Biosensors & bioelectronics.

[162]  G. Kovacs,et al.  Microfabricated solid-state dissolved oxygen sensor , 2002 .

[163]  C. Amatore,et al.  Comparison of apex and bottom secretion efficiency at chromaffin cells as measured by amperometry. , 2007, Biophysical chemistry.

[164]  Lars Samuelson,et al.  Position-controlled interconnected InAs nanowire networks. , 2006, Nano letters.

[165]  Jenny Zhu,et al.  Label-free, real-time monitoring of IgE-mediated mast cell activation on microelectronic cell sensor arrays. , 2004, Journal of immunological methods.

[166]  Dana M. Spence,et al.  A Microchip‐Based System for Immobilizing PC 12 Cells and Amperometrically Detecting Catecholamines Released After Stimulation with Calcium , 2005 .

[167]  H. Shiku,et al.  Amperometric detection of the bacterial metabolic regulation with a microbial array chip. , 2005, Biosensors & bioelectronics.

[168]  M. Koudelka-Hep,et al.  Amperometric fluidic microchip array sensing device for nitric oxide determination in solution , 2006 .

[169]  Sihai Chen,et al.  Plasmonic detection of a model analyte in serum by a gold nanorod sensor. , 2007, Analytical chemistry.

[170]  S. Negash,et al.  Cdk5 regulates cell-matrix and cell-cell adhesion in lens epithelial cells. , 2002, Journal of cell science.

[171]  Julian A. T. Dow,et al.  Single cell mobility and adhesion monitoring using extracellular electrodes , 1991 .

[172]  A. Bard,et al.  Scanning electrochemical microscopy. Introduction and principles , 1989 .

[173]  George M. Whitesides,et al.  Extending Microcontact Printing as a Microlithographic Technique , 1997 .

[174]  K. Tanizawa,et al.  Differential measurement with a microfluidic device for the highly selective continuous measurement of histamine released from rat basophilic leukemia cells (RBL-2H3). , 2002, Lab on a chip.

[175]  C. James,et al.  An electrochemical detector array to study cell biology on the nanoscale. , 2002 .

[176]  Lars Montelius,et al.  Nanoelectrochemical transducers for (bio-) chemical sensor applications fabricated by nanoimprint lithography , 2004 .

[177]  A. Ewing,et al.  Intracellular Analysis with an Immobilized-Enzyme Glucose Electrode Havine 2-Micrometers Diameter and Subsecond Response Times , 1991 .

[178]  B Wolf,et al.  Functional cellular assays with multiparametric silicon sensor chips. , 2003, Lab on a chip.

[179]  D. Sullivan,et al.  Plasmodium falciparum-infected erythrocytes decrease the integrity of human blood-brain barrier endothelial cell monolayers. , 2007, The Journal of infectious diseases.

[180]  W. Mcentee,et al.  Glutamate: its role in learning, memory, and the aging brain , 2005, Psychopharmacology.

[181]  K. Cole The advance of electrical models for cells and axons. , 1962, Biophysical journal.

[182]  J H Luong,et al.  Monitoring motility, spreading, and mortality of adherent insect cells using an impedance sensor. , 2001, Analytical chemistry.

[183]  Surendra K. Ravula,et al.  Micro electrical impedance spectroscopy of bovine chromaffin cells , 2002, 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578).

[184]  H. Andersson,et al.  Microfluidic devices for cellomics: a review , 2003 .

[185]  H. Shiku,et al.  On-chip electrochemical measurement of beta-galactosidase expression using a microbial chip. , 2004, Chemical communications.

[186]  Sungbo Cho,et al.  Impedance monitoring of herpes simplex virus-induced cytopathic effect in Vero cells , 2007 .

[187]  Christian Amatore,et al.  Electrochemical detection in a microfluidic device of oxidative stress generated by macrophage cells. , 2007, Lab on a chip.

[188]  R. Kennedy,et al.  Oxygen microsensor and its application to single cells and mouse pancreatic islets. , 1999, Analytical chemistry.

[189]  D. Ralph,et al.  Nanometer-scale scanning sensors fabricated using stencil lithography , 2003 .

[190]  H. Galla,et al.  Murine brain capillary endothelial cells exhibit improved barrier properties under the influence of hydrocortisone , 2005, Brain Research.

[191]  D.M. Wilson,et al.  Sensor technologies for monitoring metabolic activity in single cells-part II: nonoptical methods and applications , 2004, IEEE Sensors Journal.

[192]  Yong Chen,et al.  Coupling of electrochemistry and fluorescence microscopy at indium tin oxide microelectrodes for the analysis of single exocytotic events. , 2006, Angewandte Chemie.

[193]  H. Schwan Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.

[194]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[195]  J. Oni,et al.  Simultaneous detection of the release of glutamate and nitric oxide from adherently growing cells using an array of glutamate and nitric oxide selective electrodes. , 2005, Biosensors & bioelectronics.

[196]  P. Dodd,et al.  Glutamate-mediated excitotoxicity and neurodegeneration in Alzheimer’s disease , 2004, Neurochemistry International.

[197]  I. Giaever,et al.  Electric measurements can be used to monitor the attachment and spreading of cells in tissue culture. , 1991, BioTechniques.

[198]  Xiao Xu,et al.  Label-Free and Real-Time Cell-Based Kinase Assay for Screening Selective and Potent Receptor Tyrosine Kinase Inhibitors Using Microelectronic Sensor Array , 2006, Journal of biomolecular screening.

[199]  C. Sanchez,et al.  A selective chemical sensor based on the plasmonic response of phosphinine-stabilized gold nanoparticles hosted on periodically organized mesoporous silica thin layers. , 2005, Small.

[200]  Eugen Gheorghiu,et al.  Measuring living cells using dielectric spectroscopy , 1996 .

[201]  Joachim Wegener,et al.  Electrical wound-healing assay for cells in vitro. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[202]  Ales Prokop,et al.  A microphysiometer for simultaneous measurement of changes in extracellular glucose, lactate, oxygen, and acidification rate. , 2004, Analytical chemistry.

[203]  Wen‐Chang Chen,et al.  Electrochemical Characterization of Screen‐Printed Carbon Electrodes by Modification with Chitosan Oligomers , 2005 .

[204]  K. Gillis,et al.  On-chip amperometric measurement of quantal catecholamine release using transparent indium tin oxide electrodes. , 2006, Analytical chemistry.

[205]  Ralf Ehret,et al.  Real-time assessment of cytotoxicity by impedance measurement on a 96-well plate , 2007 .

[206]  A. Ewing,et al.  Chemical analysis of single cells and exocytosis. , 1997, Critical reviews in neurobiology.

[207]  Mark R Cookson,et al.  The biochemistry of Parkinson's disease. , 2005, Annual review of biochemistry.

[208]  Tomoyuki Yasukawa,et al.  Oxygen consumption of cell suspension in a poly(dimethylsiloxane) (PDMS) microchannel estimated by scanning electrochemical microscopy. , 2006, The Analyst.

[209]  R. Tepper,et al.  Cockroach extract antigen increases bronchial airway epithelial permeability. , 2002, The Journal of allergy and clinical immunology.

[210]  Ju Hun Yeon,et al.  Cytotoxicity test based on electrochemical impedance measurement of HepG2 cultured in microfabricated cell chip. , 2005, Analytical biochemistry.

[211]  J. A. Jankowski,et al.  Analysis of diffusional broadening of vesicular packets of catecholamines released from biological cells during exocytosis. , 1992, Analytical chemistry.

[212]  O. Niwa Electroanalytical Chemistry with Carbon Film Electrodes and Micro and Nano-Structured Carbon Film-Based Electrodes , 2005 .

[213]  Shoko Iwaki,et al.  Real-time monitoring of histamine released from rat basophilic leukemia (RBL-2H3) cells with a histamine microsensor using recombinant histamine oxidase. , 2002, Analytical biochemistry.

[214]  Horiuchi,et al.  Subnanoliter volume wall-jet cells combined with interdigitated microarray electrode and enzyme modified planar microelectrode , 2000, Analytical chemistry.

[215]  I. Giaever,et al.  Prostaglandin E2 elicits a morphological change in cultured orbital fibroblasts from patients with Graves ophthalmopathy. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[216]  J. Wegener,et al.  Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces. , 2000, Experimental cell research.

[217]  D. Knecht,et al.  Automated real-time measurements of leukocyte chemotaxis. , 2007, Journal of immunological methods.

[218]  I. Ges,et al.  Differential pH measurements of metabolic cellular activity in nl culture volumes using microfabricated iridium oxide electrodes. , 2007, Biosensors & bioelectronics.

[219]  Godfrey L. Smith,et al.  Ultra-low-volume, real-time measurements of lactate from the single heart cell using microsystems technology. , 2002, Analytical chemistry.

[220]  Eugenia Wang,et al.  Use of electric cell-substrate impedance sensing as a tool for quantifying cytopathic effect in influenza A virus infected MDCK cells in real-time. , 2005, Journal of virological methods.

[221]  E. Lundgren,et al.  Improving InAs nanotree growth with composition-controlled Au–In nanoparticles , 2006 .

[222]  M. Kaplan,et al.  Respiratory syncytial virus causes increased bronchial epithelial permeability. , 2004, Chest.

[223]  H. Shiku,et al.  Fabrication of microbial chip using collagen gel microstructure. , 2003, Lab on a chip.

[224]  K. Torimitsu,et al.  Microfabricated On-Line Sensor for Continuous Monitoring of l-Glutamate , 1998 .

[225]  Chun-Min Lo,et al.  Cell–substrate impedance analysis of epithelial cell shape and micromotion upon challenge with bacterial proteins that perturb extracellular matrix and cytoskeleton , 1998 .

[226]  C. Lo,et al.  Monitoring motion of confluent cells in tissue culture. , 1993, Experimental cell research.