무전극 형광램프 시스템의 서어지 특성 연구

In this paper, we have investigated the inductive voltages, currents, frequency of output line of electrodeless fluorescent lamp system as an surge is supplied and have analyzed the surge characteristics as an phase alteration of input voltage with an surge suppling. A result of measurement is that the inductive over- voltages(H-PE, N-PE) on output line of electrodeless fluorescent lamp system showed more high than inductive overvoltages of H(hot)-N(neutral) line. Therefore, designer of system will lay emphasis on an protective circuit with considering an overvoltage(H-PE, N-PE) or phase of input voltage.