Epileptogenic Zone Localization With 18FDG PET Using a New Dynamic Parametric Analysis

Introduction: [18F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) is part of the regular preoperative work-up in medically refractory epilepsy. As a complement to visual evaluation of PET, statistical parametric maps can help in the detection of the epileptogenic zone (EZ). However, software packages currently available are time-consuming and little intuitive for physicians. We develop a user-friendly software (referred as PET-analysis) for EZ localization in PET studies that allows dynamic real-time statistical parametric analysis. To evaluate its performance, the outcome of PET-analysis was compared with the results obtained by visual assessment and Statistical Parametric Mapping (SPM). Methods: Thirty patients with medically refractory epilepsy who underwent presurgical 18F-FDG PET with good post-operative outcomes were included. The 18F-FDG PET studies were evaluated by visual assessment, with SPM8 and PET-analysis. In SPM, parametric T-maps were thresholded at corrected p < 0.05 and cluster size k = 50 and at uncorrected p < 0.001 and k = 100 (the most used parameters in the literature). Since PET-analysis rapidly processes different threshold combinations, T-maps were thresholded with multiple p-value and different clusters sizes. The presurgical EZ identified by visual assessment, SPM and PET-analysis was compared to the confirmed EZ according to post-surgical follow-up. Results: PET-analysis obtained 66.7% (20/30) of correctly localizing studies, comparable to the 70.0% (21/30) achieved by visual assessment and significantly higher (p < 0.05) than that obtained with the SPM threshold p < 0.001/k = 100, of 36.7% (11/30). Only one study was positive, albeit non-localizing, with the SPM threshold corrected p < 0.05/k = 50. Concordance was substantial for PET-analysis (κ = 0.643) and visual interpretation (κ = 0.622), being fair for SPM (κ = 0.242). Conclusion: Compared to SPM with the fixed standard parameters, PET-analysis may be superior in EZ localization with its easy and rapid processing of different threshold combinations. The results of this initial proof-of-concept study validate the clinical use of PET-analysis as a robust objective complementary tool to visual assessment for EZ localization.

[1]  Rui Feng,et al.  Surgical Treatment of MRI-Negative Temporal Lobe Epilepsy Based on PET: A Retrospective Cohort Study , 2014, Stereotactic and Functional Neurosurgery.

[2]  Alejandro F. Frangi,et al.  FocusDET, A New Toolbox for SISCOM Analysis. Evaluation of the Registration Accuracy Using Monte Carlo Simulation , 2012, Neuroinformatics.

[3]  P. Merlet,et al.  FDG-PET improves surgical outcome in negative MRI Taylor-type focal cortical dysplasias , 2010, Neurology.

[4]  Jae Sung Lee,et al.  Diagnostic performance of 18F-FDG PET and ictal 99mTc-HMPAO SPET in pediatric temporal lobe epilepsy: Quantitative analysis by statistical parametric mapping, statistical probabilistic anatomical map, and subtraction ictal SPET , 2005, Seizure.

[5]  N. Bargalló,et al.  Validation of FDG‐PET/MRI coregistration in nonlesional refractory childhood epilepsy , 2011, Epilepsia.

[6]  Douglas G. Altman,et al.  Explanation and Elaboration , 2022 .

[7]  Dennis Andersson,et al.  A retrospective cohort study , 2018 .

[8]  Karl J. Friston,et al.  Statistical parametric mapping in functional neuroimaging: beyond PET and fMRI activation studies. , 1998, European journal of nuclear medicine.

[9]  N. Tzourio-Mazoyer,et al.  Automated Anatomical Labeling of Activations in SPM Using a Macroscopic Anatomical Parcellation of the MNI MRI Single-Subject Brain , 2002, NeuroImage.

[10]  N. Bargalló,et al.  Seizure‐onset zone localization by statistical parametric mapping in visually normal 18F‐FDG PET studies , 2016, Epilepsia.

[11]  Kai Zhang,et al.  Glucose Metabolic Profile by Visual Assessment Combined with Statistical Parametric Mapping Analysis in Pediatric Patients with Epilepsy , 2017, The Journal of Nuclear Medicine.

[12]  C. Sarkar,et al.  Role of concordance between ictal-subtracted SPECT and PET in predicting long-term outcomes after epilepsy surgery , 2014, Epilepsy Research.

[13]  D. Rennie,et al.  The STARD statement for reporting studies of diagnostic accuracy: explanation and elaboration. , 2003, Annals of internal medicine.

[14]  F. Leijten,et al.  Can we increase the yield of FDG-PET in the preoperative work-up for epilepsy surgery? , 2014, Epilepsy Research.

[15]  Claudio Pollo,et al.  Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients , 2011, Brain : a journal of neurology.

[16]  K. Byth,et al.  The topography and significance of extratemporal hypometabolism in refractory mesial temporal lobe epilepsy examined by FDG‐PET , 2010, Epilepsia.

[17]  Dong Soo Lee,et al.  (18)F-FDG PET in localization of frontal lobe epilepsy: comparison of visual and SPM analysis. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  Max A. Viergever,et al.  elastix: A Toolbox for Intensity-Based Medical Image Registration , 2010, IEEE Transactions on Medical Imaging.

[19]  M. Sperling,et al.  Surgical outcome in PET‐positive, MRI‐negative patients with temporal lobe epilepsy , 2012, Epilepsia.

[20]  Lucie Hertz-Pannier,et al.  Optimizing statistical parametric mapping analysis of 18F-FDG PET in children , 2013, EJNMMI Research.

[21]  M. J. Jang,et al.  Disparity of Perfusion and Glucose Metabolism of Epileptogenic Zones in Temporal Lobe Epilepsy Demonstrated by SPM/SPAM Analysis on 15O Water PET, [18F]FDG‐PET, and [99mTc]‐HMPAO SPECT , 2001, Epilepsia.

[22]  Otto Muzik,et al.  Objective Detection of Epileptic Foci by 18F-FDG PET in Children Undergoing Epilepsy Surgery , 2010, The Journal of Nuclear Medicine.

[23]  George Jallo,et al.  The evaluation of FDG-PET imaging for epileptogenic focus localization in patients with MRI positive and MRI negative temporal lobe epilepsy , 2013, Neuroradiology.

[24]  Xavier Setoain,et al.  Clinical Role of Subtraction Ictal SPECT Coregistered to MR Imaging and 18F-FDG PET in Pediatric Epilepsy , 2014, The Journal of Nuclear Medicine.

[25]  Mijin Yun,et al.  Relationship between bilateral temporal hypometabolism and EEG findings for mesial temporal lobe epilepsy: Analysis of 18F-FDG PET using SPM , 2006, Seizure.

[26]  H. Amthauer,et al.  Use of statistical parametric mapping of 18F-FDG-PET in frontal lobe epilepsy , 2003, Nuklearmedizin.

[27]  N. Bargalló,et al.  PET/MRI and PET/MRI/SISCOM coregistration in the presurgical evaluation of refractory focal epilepsy , 2015, Epilepsy Research.