Grid voltage offset and harmonics rejection using second order generalized integrator and kalman filter technique

This paper proposes the application of second order generalized integrator (SOGI) and Kalman filter (KF) technique for the rejection of DC offset and harmonics from the distorted grid voltage waveform. The SOGI is used to estimate the orthogonal waveforms of grid voltage fundamental frequency component. On the other hand, the linear Kalman filter (LKF) is used to reject the DC offset and harmonics present in the distorted grid voltage waveform. The resonance and harmonic frequencies of the SOGI and LKF, respectively, are provided by the frequency locked loop (FLL). The proposed technique provides better results to reject the DC offset and harmonics as compared to the multiple SOGI (MSOGI) technique. The improved performance of the proposed technique is due to the use of LKF which not only rejects the DC offset and harmonics but also non-sensitive to the change of SOGI's gain. Synthetically generated grid voltage waveforms are used in MATLAB/Simulink to depict the superior performance of the proposed SOGI-LKF technique as compared to the MSOGI with/without offset rejection technique.

[1]  C A G Marques,et al.  Improved Disturbance Detection Technique for Power-Quality Analysis , 2011, IEEE Transactions on Power Delivery.

[2]  J. Arrillaga,et al.  An adaptive Kalman filter for dynamic harmonic state estimation and harmonic injection tracking , 2005, IEEE Transactions on Power Delivery.

[3]  Adly A. Girgis,et al.  Identification and tracking of harmonic sources in a power system using a Kalman filter , 1996 .

[4]  M. M. Morcos,et al.  Artificial Intelligence and Advanced Mathematical Tools for Power Quality Applications: A Survey , 2001, IEEE Power Engineering Review.

[5]  F. Blaabjerg,et al.  Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.

[6]  Soon-Ryul Nam,et al.  Phasor Estimation in the Presence of DC Offset and CT Saturation , 2009, IEEE Transactions on Power Delivery.

[7]  G.W. Chang,et al.  Extended Real Model of Kalman Filter for Time-Varying Harmonics Estimation , 2010, IEEE Transactions on Power Delivery.

[8]  M. Karimi-Ghartemani,et al.  Addressing DC Component in PLL and Notch Filter Algorithms , 2012, IEEE Transactions on Power Electronics.

[9]  P. K. Jain,et al.  Problems of Startup and Phase Jumps in PLL Systems , 2012, IEEE Transactions on Power Electronics.

[10]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[11]  F. Blaabjerg,et al.  Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[12]  R. Teodorescu,et al.  A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions , 2012, IEEE Transactions on Power Electronics.

[13]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[14]  V.G. Agelidis,et al.  Offset rejection for PLL based synchronization in grid-connected converters , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[15]  Liuchen Chang,et al.  Frequency measurement using a frequency locked loop , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[16]  R. Teodorescu,et al.  Multiple second order generalized integrators for harmonic synchronization of power converters , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[17]  F. Blaabjerg,et al.  Grid synchronization of power converters using multiple second order generalized integrators , 2008, 2008 34th Annual Conference of IEEE Industrial Electronics.