Do commercial buildings become less efficient when they provide grid ancillary services?

Commercial buildings offer a vast thermal energy storage capability. Control of building heating, ventilation, and air conditioning (HVAC) systems can potentially be used to balance variations in renewable generation and load. Specifically, buildings can provide ancillary services to the grid by decreasing and increasing consumption with respect to their baseline, making them appear as energy storage to the power system operator. However, a recent study has shown that buildings providing these services tend to consume more energy, resulting in a low effective round-trip efficiency. To explore this phenomenon further, experiments were conducted on three buildings on the University of Michigan campus. The buildings were chosen to provide a variety in structure, size, and HVAC system layout. They were instrumented in early summer of 2017 and baseline power and building automation system (BAS) data were collected for several months in 2017 and 2018. The building thermostats were then perturbed through predefined patterns emulating ancillary service events, enabling detailed investigation of the resulting electrical energy consumption. This paper presents experimental results, focusing on the additional energy consumed and effective input/output efficiency. The three buildings respond with mean round-trip efficiencies ranging from 34 to 81%, with individual tests yielding efficiencies far outside that range. We also find that the efficiency of building response depends on the magnitude and polarity of the temperature setpoint changes. Our results are consistent with past experimental results, but inconsistent with past modeling results. This indicates that the models need to be improved in order to capture the energy impacts of ancillary service provision by buildings.

[1]  Johanna L. Mathieu,et al.  Explaining inefficiencies in commercial buildings providing power system ancillary services , 2017 .

[2]  David H. Blum,et al.  Opportunity Cost Quantification for Ancillary Services Provided by Heating, Ventilating, and Air-Conditioning Systems , 2017, IEEE Transactions on Smart Grid.

[3]  Sanna Syri,et al.  Electrical energy storage systems: A comparative life cycle cost analysis , 2015 .

[4]  Prabir Barooah,et al.  On the Round-Trip Efficiency of an HVAC-Based Virtual Battery , 2018, IEEE Transactions on Smart Grid.

[5]  Sean P. Meyn,et al.  Ancillary Service to the Grid Through Control of Fans in Commercial Building HVAC Systems , 2014, IEEE Transactions on Smart Grid.

[6]  Duncan S. Callaway,et al.  Experimental Demonstration of Frequency Regulation by Commercial Buildings—Part II: Results and Performance Evaluation , 2018, IEEE Transactions on Smart Grid.

[7]  Vincent J. Cushing,et al.  Optimizing commercial building participation in energy and ancillary service markets , 2014 .

[8]  Johanna L. Mathieu,et al.  An experimental study of energy consumption in buildings providing ancillary services , 2017, 2017 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

[9]  Evangelos Vrettos,et al.  Robust Energy-Constrained Frequency Reserves From Aggregations of Commercial Buildings , 2015, IEEE Transactions on Power Systems.

[10]  Colin N. Jones,et al.  Experimental Implementation of Frequency Regulation Services Using Commercial Buildings , 2017, IEEE Transactions on Smart Grid.

[11]  Johanna L. Mathieu,et al.  Variability in automated responses of commercial buildings and industrial facilities to dynamic elec , 2011 .

[12]  Duncan S. Callaway,et al.  Experimental Demonstration of Frequency Regulation by Commercial Buildings—Part I: Modeling and Hierarchical Control Design , 2016, IEEE Transactions on Smart Grid.

[13]  Gregor P. Henze,et al.  Evaluation of optimal control for active and passive building thermal storage , 2004 .

[14]  Ian A. Hiskens,et al.  Frequency Regulation From Commercial Building HVAC Demand Response , 2016, Proceedings of the IEEE.

[15]  Scott Backhaus,et al.  Model Development and Identification for Fast Demand Response in Commercial HVAC Systems , 2014, IEEE Transactions on Smart Grid.

[16]  Ian A. Hiskens,et al.  Achieving Controllability of Electric Loads , 2011, Proceedings of the IEEE.

[17]  James E. Braun,et al.  Laboratory demonstration of variable-speed packaged air-conditioning units for provision of frequency regulation services , 2018, 2018 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

[18]  Mo Chen,et al.  Contract design for frequency regulation by aggregations of commercial buildings , 2014, 2014 52nd Annual Allerton Conference on Communication, Control, and Computing (Allerton).

[19]  Sean P. Meyn,et al.  Experimental Evaluation of Frequency Regulation From Commercial Building HVAC Systems , 2015, IEEE Transactions on Smart Grid.

[20]  Scott Backhaus,et al.  Round-trip efficiency of fast demand response in a large commercial air conditioner , 2015 .

[21]  Sila Kiliccote,et al.  Strategies for Demand Response in Commercial Buildings , 2006 .

[22]  Peng Zhao,et al.  Evaluation of commercial building HVAC systems as frequency regulation providers , 2013 .