Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution system

This paper proposes the cooperative control of multiple active filters based on voltage detection for harmonic damping throughout a power distribution system. The arrangement of a real distribution system would be changed according to system operation, and/or fault conditions. In addition, shunt capacitors and loads are individually connected to, or disconnected from, the distribution system. Independent control might make multiple active filters produce unbalanced compensating currents. This paper presents hardware and software implementations of cooperative control for two active filters. Experimental results verify the effectiveness of the cooperative control with the help of a communication system.

[1]  G. Lemieux Power system harmonic resonance: a documented case , 1988, Conference Record of 1988 Annual Pulp and Paper Industry Technical Conference.

[2]  Osamu Nakamura,et al.  Measurement and Analysis of Harmonics in Distribution Systems and Development of a Harmonics Suppression Method , 1994 .

[3]  E. J. Currence,et al.  Harmonic resonance at a medium sized industrial plant , 1994 .

[4]  Hirofumi Akagi Control Strategy and Site Selection of a Shunt Active Filter for Damping of Harmonic Propagation in Power Distribution Systems , 1997 .

[5]  W. M. Grady,et al.  Minimizing harmonic voltage distortion with multiple current-constrained active power line conditioners , 1997 .

[6]  H. Akagi,et al.  A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[7]  Damir Novosel,et al.  Automated solutions for distribution feeders , 2000 .

[8]  Takamu Genji,et al.  Development and proof examination result of Active Filter for Power Distribution Systems , 2000 .

[9]  Tien-Ting Chang,et al.  An efficient approach for reducing harmonic voltage distortion in distribution systems with active power line conditioners , 2000 .

[10]  K. Wada,et al.  Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[11]  D. J. Marihart Communications technology guidelines for EMS/SCADA systems , 2001 .

[12]  Hirofumi Akagi,et al.  Control and performance of a fully-digital-controlled shunt active filter for installation on a power distribution system , 2002 .

[13]  Hirofumi Akagi,et al.  Implementation and performance of automatic gain adjustment in a shunt-active filter for harmonic damping throughout a power distribution system , 2002 .