Modified scaled Fourier linear combiner in thoracic impedance cardiography

New filtering algorithms; a modified scaled Fourier linear combiner (mSFLC) and a modified ensemble averaging (mEA) are proposed to remove the phase distortion of the impedance waveform caused by SFLC. Performance of the filters is assessed from the shape of the filtered waveform and the estimation of systolic time intervals. It was found that the mSFLC and mEA could compensate for drawbacks of the SFLC and precisely reproduce the impedance waveforms; however, misinterpretation and attenuation in the cardiac variables may be caused when abrupt changes or irregularities occur in the source waveform.

[1]  S. B. Raza,et al.  Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal , 1992, Medical and Biological Engineering and Computing.

[2]  T. Yambe,et al.  Validity of the adaptive filter for accurate measurement of cardiac output in impedance cardiography. , 2004, The Tohoku journal of experimental medicine.

[3]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[4]  P. M. McCabe,et al.  New signal processing techniques for improved precision of noninvasive impedance cardiography , 2006, Annals of Biomedical Engineering.

[5]  S. Mohapatra,et al.  Non Invasive Cardiovascular Monitoring by Electrical Impedance Technique , 1988 .

[6]  Y. Miyamoto,et al.  Continuous determination of cardiac output during exercise by the use of impedance plethysmography , 1981, Medical and Biological Engineering and Computing.

[7]  D. Theisen,et al.  Impedance cardiography applied to maximal arm cranking exercise: a matter of sampling and processing strategy. , 1998, Medicine and science in sports and exercise.

[8]  R. Gotshall,et al.  Impedance Cardiography: Noninvasive Assessment of Human Central Hemodynamics at Rest and During Exercise , 1989, Exercise and sport sciences reviews.

[9]  T Kobayashi,et al.  Noninvasive evaluation of cardiac output during postural change and exercise in humans: comparison between the modelflow and pulse dye-densitometry. , 2004, The Japanese journal of physiology.

[10]  Tomoyuki Yambe,et al.  Beat-to-beat evaluation of systolic time intervals during bicycle exercise using impedance cardiography. , 2004, The Tohoku journal of experimental medicine.

[11]  P E Leaverton,et al.  The First Derivative Thoracic Impedance Cardiogram , 1970, Circulation.

[12]  D C Jeutter,et al.  Determination of cardiac output using ensemble-averaged impedance cardiograms. , 1985, Journal of applied physiology.

[13]  Y. Yasuda,et al.  Filtering noncorrelated noise in impedance cardiography , 1995, IEEE Transactions on Biomedical Engineering.

[14]  Design and implementation of a digital filter for beat-by-beat impedance cardiography , 1988, IEEE Transactions on Biomedical Engineering.

[15]  Roman Trobec,et al.  Beat-to-beat QT interval variability before and after cardiac surgery , 2003, Comput. Biol. Medicine.