Axillary nerve temperatures during radiofrequency capsulorrhaphy of the shoulder.

PURPOSE The purpose of this study was to determine the temperatures along the course of the axillary nerve during radiofrequency (RF) capsulorrhaphy of the shoulder in a cadaver model. The hypothesis of this project was that temperatures capable of damaging neural tissue would be recorded during simulated RF capsulorrhaphy. TYPE OF STUDY Basic science evaluation. METHODS This study used 9 fresh-frozen cadaver shoulder capsules removed en bloc along with the underlying axillary nerve and soft tissue. The axillary nerve was instrumented with 4 thermocouples placed along the course of the nerve (2 thermocouples anterior and 2 posterior to the 6 o'clock position, spaced 7 mm apart). Each of the specimens underwent RF thermal capsulorrhaphy during which the temperature at each of the thermocouple positions was continuously recorded. RESULTS The average of the maximum temperature at each of the 4 positions measured along the course of the axillary nerve were 52.2 +/- 18.0 degrees C at the most anterior place probed, 45.8 +/- 5.44 degrees C (mid anterior), 44.5 +/- 8.7 degrees C (mid posterior), and 42.8 +/- 10.1 degrees C at the most posteriorly positioned probe. Two specimens had a maximum temperature greater than the 67 degrees C set point of the device, and 7 specimens had a maximum temperature greater than 45 degrees C in at least 1 thermocouple position. CONCLUSIONS This study shows that heating of the axillary nerve can occur during RF capsular shrinkage of the shoulder and may potentially reach levels that can damage neural tissue.

[1]  R. Loomer,et al.  Anatomy of the axillary nerve and its relation to inferior capsular shift. , 1989, Clinical orthopaedics and related research.

[2]  J. Bogdanske,et al.  The Effect of Thermal Heating on the Length and Histologic Properties of the Glenohumeral Joint Capsule , 1997, The American journal of sports medicine.

[3]  G. Fanton Arthroscopic electrothermal surgeryof the shoulder , 1998 .

[4]  B Zarins,et al.  The Thermal Properties of Bovine Joint Capsule , 1997, The American journal of sports medicine.

[5]  H. Tullos,et al.  The axillary nerve and its relationship to common sports medicine shoulder procedures , 1986, The American journal of sports medicine.

[6]  P. Hecht,et al.  The Thermal Effect of Monopolar Radiofrequency Energy on the Properties of Joint Capsule , 1998, The American journal of sports medicine.

[7]  H Calkins,et al.  Temperature monitoring during radiofrequency catheter ablation of accessory pathways. , 1992, Circulation.

[8]  Markel,et al.  The effect of radiofrequency energy on the length and temperature properties of the glenohumeral joint capsule. , 1998, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[9]  S H Lee,et al.  Temperature and impedance monitoring during radiofrequency catheter ablation of slow AV node pathway in patients with atrioventricular node reentrant tachycardia. , 1996, International journal of cardiology.

[10]  R. Hawkins,et al.  The Relationship of the Axillary Nerve to Arthroscopically Placed Capsulolabral Sutures , 1998, The American journal of sports medicine.

[11]  G. Bain,et al.  Arthroscopic relationship of the axillary nerve to the shoulder joint capsule: an anatomic study. , 1999, Journal of shoulder and elbow surgery.

[12]  S. Eliasson,et al.  Sciatic nerve function following hindlimb thermal injury. , 1987, The Journal of surgical research.