Postcardiotomy centrifugal mechanical ventricular support.

From August 1979 through August 1991, 91 patients were supported with centrifugal mechanical ventricular assist. Major indications for its use were postcardiotomy ventricular failure (79) or as a bridge to cardiac transplantation (12). In postcardiotomy use (0.2% of all cardiac procedures), there were 54 male (68.4%) and 25 female patients (31.6%) with a mean age of 54.8 years and a mean duration of use of 3.56 days (range, 1 hour to 19 days). Forty-nine patients (62%) were successfully weaned, and 20 (25.3%) were hospital survivors. In 57 patients the device was inserted to wean from cardiopulmonary bypass, whereas in 22 it was employed later in the postoperative period because of low cardiac output or sudden arrest. Thirty-four (59.6%) of the 57 patients in the former group were weaned, and 15 (26.3%) were discharged, results similar to those in the latter group with 15 (68.2%) weaned and 5 (22.7%) discharged. Morbidity associated with use of centrifugal blood pumps included bleeding (87.3%; mean transfusion requirement, 53.2 units), renal failure (46.8%), cerebrovascular accident (12.7%), thromboembolism (12.7%), and hepatic insufficiency (12.7%). After a mean follow-up of 45.4 months (range, 2 to 142 months), 7 patients had died (35% late mortality), 1 patient is in functional class IV, and all others are in functional class I or II. Lower survival was associated with biventricular failure and renal failure but not with age or sex of the patient.

[1]  M E DeBakey,et al.  Left ventricular bypass pump for cardiac assistance. Clinical experience. , 1971, The American journal of cardiology.

[2]  J. Piehler,et al.  Bio-medicus ventricular assist device for salvage of cardiac surgical patients. , 1991, The Annals of thoracic surgery.

[3]  T. Karl,et al.  Centrifugal pump left heart assist in pediatric cardiac operations. Indication, technique, and results. , 1991, The Journal of thoracic and cardiovascular surgery.

[4]  G P Noon,et al.  Bio-medicus ventricular assistance. , 1991, The Annals of thoracic surgery.

[5]  C. Miller,et al.  Combined registry for the clinical use of mechanical ventricular assist devices. Postcardiotomy cardiogenic shock. , 1990, ASAIO transactions.

[6]  D. Pennington,et al.  Follow-up of survivors of mechanical circulatory support. , 1988, The Journal of thoracic and cardiovascular surgery.

[7]  R. Kao,et al.  Mechanical support of the failing heart. , 1986, The Annals of thoracic surgery.

[8]  F. Spencer,et al.  Late functional and hemodynamic status of surviving patients following insertion of the left heart assist device. , 1983, The Journal of thoracic and cardiovascular surgery.

[9]  F. Spencer,et al.  ASSISTED CIRCULATION FOR CARDIAC FAILURE FOLLOWING INTRACARDIAC SURGERY WITH CARDIOPULMONARY BYPASS. , 1965, The Journal of thoracic and cardiovascular surgery.

[10]  H. Laks,et al.  Clinical experience with centrifugal pump ventricular support at UCLA Medical Center. , 1988, ASAIO transactions.

[11]  M. Verani,et al.  Delayed recovery of severely "stunned" myocardium with the support of a left ventricular assist device after coronary artery bypass graft surgery. , 1987, Journal of the American College of Cardiology.

[12]  D. Pennington,et al.  Univentricular versus biventricular assist device support. , 1991, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[13]  W. Pae,et al.  Long-term results of ventricular assist pumping in postcardiotomy cardiogenic shock. , 1987, The Journal of thoracic and cardiovascular surgery.

[14]  L. Joyce,et al.  Experience with the Sarns centrifugal pump as a ventricular assist device. , 1990, ASAIO transactions.

[15]  E. Braunwald,et al.  The Stunned Myocardium: Prolonged, Postischemic Ventricular Dysfunction , 1982, Circulation.

[16]  L. Golding Postcardiotomy mechanical support. , 1991, Seminars in thoracic and cardiovascular surgery.

[17]  A. Gazzaniga,et al.  Clinical choices for circulatory assist devices. , 1990, ASAIO transactions.

[18]  D. Pennington,et al.  Long-term follow-up of postcardiotomy patients with profound cardiogenic shock treated with ventricular assist devices. , 1985, Circulation.

[19]  W. Pierce,et al.  Survival and Complications Following Ventricular Assist Pumping for Cardiogenic Shock , 1983, Annals of surgery.

[20]  W. Pae,et al.  Ventricular-assist pumping in patients with cardiogenic shock after cardiac operations. , 1981, The New England journal of medicine.

[21]  Y Nosé,et al.  Initial clinical experience with a new temporary left ventricular assist device. , 1980, The Annals of thoracic surgery.

[22]  F. Loop,et al.  Clinical results of mechanical support of the failing left ventricle. , 1982, The Journal of thoracic and cardiovascular surgery.

[23]  D. Pennington,et al.  Long-term Follow-up of Survivors of Postcardiotomy Circulatory Support , 1988, ASAIO transactions.

[24]  L. Bailey,et al.  Mechanical assistance for cardiogenic shock following cardiac surgery, myocardial infarction, and cardiac transplantation. , 1987, The Annals of thoracic surgery.