Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-Non Invasive Multicenter Italian Study for Coronary Artery Disease)

This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (≥16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85–0.95), 0.91 (95% CI 0.86–0.95), 0.94 (95% CI 0.89–0.97), 0.88 (95% CI 0.81–0.93), and 0.91 (95% CI 0.88–0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65–0.79), 0.93 (95% CI 0.87–0.97), 0.73 (95% CI 0.65–0.79), 0.93 (95% CI 0.87–0.97), and 0.82 (95% CI 0.77–0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines.

[1]  Gabriel P. Krestin,et al.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris , 2006, European Radiology.

[2]  G. Reeder Heart Disease: A Textbook of Cardiovascular Medicine , 1984 .

[3]  G. Mancia,et al.  Guidelines on the management of stable angina pectoris: executive summary: the task force on the management of stable angina pectoris of the European society of cardiology. , 2006, European heart journal.

[4]  Yasuyuki Suzuki,et al.  Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[5]  Konstantin Nikolaou,et al.  Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. , 2005, Journal of the American College of Cardiology.

[6]  Simon Wildermuth,et al.  Accuracy of MSCT coronary angiography with 64-slice technology: first experience. , 2005 .

[7]  Jonathan Lessick,et al.  Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. , 2006, JAMA.

[8]  Udo Hoffmann,et al.  Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis , 2004, Circulation.

[9]  Ulrich Baum,et al.  Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. , 2006, The American journal of cardiology.

[10]  E. Braunwald Heart Disease: A Textbook of Cardiovascular Medicine , 1992, Annals of Internal Medicine.

[11]  A. Einstein,et al.  Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. , 2007, JAMA.

[12]  Gabriel P Krestin,et al.  64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. , 2007, Journal of the American College of Cardiology.

[13]  Werner Moshage,et al.  Detection of Coronary Artery Stenoses by Contrast-Enhanced, Retrospectively Electrocardiographically-Gated, Multislice Spiral Computed Tomography , 2001, Circulation.

[14]  Werner Moshage,et al.  Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. , 2000 .

[15]  G. Raff,et al.  Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. , 2005, Journal of the American College of Cardiology.

[16]  K. Engelmann,et al.  Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. , 2002, Radiology.

[17]  P. Serruys,et al.  Large thrombus entrapped in a patent foramen ovale of the atrial septum, which apparently “disappeared” without embolic events , 2002, Heart.

[18]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[19]  M. Reiser,et al.  Correlation of coronary calcification and angiographically documented stenoses in patients with suspected coronary artery disease: results of 1,764 patients. , 2001, Journal of the American College of Cardiology.

[20]  Raymond Kwong,et al.  Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease. , 2007, Journal of the American College of Cardiology.

[21]  Pedro A. Lemos,et al.  Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed Tomography , 2002, Circulation.

[22]  Jörg Hausleiter,et al.  Radiation Dose Estimates From Cardiac Multislice Computed Tomography in Daily Practice: Impact of Different Scanning Protocols on Effective Dose Estimates , 2006, Circulation.

[23]  Alan Buckingham,et al.  Statistical Update , 1996, The Bulletin of the Ecological Society of America.

[24]  R. Frye,et al.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. , 1975, Circulation.

[25]  D. Jewitt,et al.  Manual of Otolaryngology , 1969 .

[26]  Filippo Cademartiri,et al.  Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris. , 2004, Journal of the American College of Cardiology.

[27]  E. Topol,et al.  Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. , 1995, Circulation.

[28]  S. Halliburton,et al.  Performance Evaluation of a Multi-Slice CT System with 16-Slice Detector and Increased Gantry Rotation Speed for Isotropic Submillimeter Imaging of the Heart , 2003, Herz.

[29]  J. Camm,et al.  [Guidelines on the management of stable angina pectoris: executive summary]. , 2006, Giornale italiano di cardiologia.

[30]  P. Wolf,et al.  Heart disease and stroke statistics--2006 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee. , 2006, Circulation.

[31]  C. Claussen,et al.  Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. , 2002, European heart journal.

[32]  Heshui Shi,et al.  Noninvasive Coronary Angiography With Multislice Computed Tomography , 2005 .

[33]  Konstantin Nikolaou,et al.  Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. , 2006, AJR. American journal of roentgenology.

[34]  Werner Moshage,et al.  Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT , 2000, Circulation.

[35]  Rémy Morello,et al.  Coronary arteries: diagnostic performance of 16- versus 64-section spiral CT compared with invasive coronary angiography--meta-analysis. , 2007, Radiology.

[36]  Filippo Cademartiri,et al.  Patients Referred for Diagnostic Conventional Coronary Angiography High-Resolution Spiral Computed Tomography Coronary Angiography , 2005 .

[37]  A. Knez,et al.  Quantification of Obstructive and Nonobstructive Coronary Lesions of 64-Slice Computed Tomography , 2005 .

[38]  W. Kalender,et al.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience. , 2006, European journal of radiology.

[39]  Matthijs Oudkerk,et al.  Coronary angiography with multi-slice computed tomography , 2001, The Lancet.

[40]  Borut Marincek,et al.  Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control , 2006, European Radiology.

[41]  M. D. Di Carli,et al.  New technology for noninvasive evaluation of coronary artery disease. , 2007, Circulation.

[42]  Patrick W Serruys,et al.  Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. , 2005, Journal of the American College of Cardiology.

[43]  Hatem Alkadhi,et al.  Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[44]  Stephen Schroeder,et al.  Diagnostic accuracy of noninvasive coronary imaging using 16-detector slice spiral computed tomography with 188 ms temporal resolution. , 2005, Journal of the American College of Cardiology.

[45]  C. Claussen,et al.  Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease. , 2004, Journal of the American College of Cardiology.

[46]  Konstantin Nikolaou,et al.  Dual-source CT cardiac imaging: initial experience , 2006, European Radiology.

[47]  M. Pfisterer,et al.  Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease. , 2005, European heart journal.

[48]  W. Bautz,et al.  Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction , 2003, Circulation.