Prevalence and Characteristics of Intracranial Microemboli Signals in Patients With Different Types of Prosthetic Cardiac Valves

Background and Purpose Transcranial Doppler detection of microemboli is widely described, but there is no clear evidence of the clinical significance or nature of the embolic material in vivo. Thromboembolism is a major cause of morbidity in patients with prosthetic cardiac valves. We undertook this study to evaluate the prevalence and the acoustic characteristics of microembolic signals in three groups of patients with different prosthetic valves. Methods One hundred seventy-nine patients with prosthetic cardiac valves (85 Bjork-Shiley, 56 Medtronic-Hall, and 38 Carpentier-Edwards) and 25 normal subjects were examined using transcranial Doppler. Monitoring time was 30 minutes over the right middle cerebral artery. Results The prevalence and numbers of embolic signals were significantly higher in patients with Bjork-Shiley compared with those with Medtronic-Hall and Carpentier-Ed- wards valves (89% versus 50% and 53%, respectively; P<.001, χ2; 156 [112, 204] versus 2 [1, 4] and 2 [1, 4] signals/h, respectively; median [95% nonparametric confidence interval], both P<.001, multiple comparisons, Bonferroni correction). The signal intensity was significantly higher in patients with Bjork-Shiley and Medtronic-Hall valves than patients with Carpentier-Edwards valves (2435 [2345, 2527] and 2120 [1745, 2483] versus 225 [184, 287] power units, median [95% confidence interval], both P<.001). No correlation was found between embolic signal numbers and clinical parameters including history of neurological deficit, cardiac rhythm, duration of artificial valve, previous cardiac operations, or intensity of anticoagulation. Embolic signals were not detected in any of the control subjects. Conclusions Our data showed that the prevalence, quantity, and acoustic characteristics of Doppler embolic signals differ in patients having three different types of prosthetic heart valves. However, no correlation with clinical parameters was identified.

[1]  M. Spencer,et al.  Detection of microemboli in patients with artificial heart valves using transcranial Doppler: preliminary observations. , 1993, The Journal of heart valve disease.

[2]  K. Lees,et al.  Quantification of Ultrasound Emboli Signals in Patients With Cardiac and Carotid Disease , 1993, Stroke.

[3]  B. Arnolds,et al.  Transcranial Doppler sonography. Examination technique and normal reference values. , 1986, Ultrasound in medicine & biology.

[4]  Helmuth Steinmetz,et al.  Detection of Intracranial Emboli in Patients With Symptomatic Extracranial Carotid Artery Disease , 1992, Stroke.

[5]  J A Zivin,et al.  Detection of arterial emboli using Doppler ultrasound in rabbits. , 1991, Stroke.

[6]  L R Sauvage,et al.  Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography. , 1990, Stroke.

[7]  H. Reul,et al.  Cavitation Potential of Mechanical Heart Valve Prostheses , 1991, The International journal of artificial organs.

[8]  M. Aosaki Thromboembolism in patients with prosthetic heart valves , 1985 .

[9]  T. Treasure,et al.  Microemboli and Cerebral Impairment During Cardiac Surgery , 1990 .

[10]  J. Linley,et al.  The detection of microemboli in the middle cerebral artery during cardiopulmonary bypass: a transcranial Doppler ultrasound investigation using membrane and bubble oxygenators. , 1987, The Annals of thoracic surgery.

[11]  R. Gosling,et al.  Monitoring middle cerebral artery blood velocity during carotid endarterectomy , 1986, The British journal of surgery.

[12]  P. Wolf,et al.  Asymptomatic carotid bruit and risk of stroke. The Framingham study. , 1981, JAMA.

[13]  Hugh S. Markus,et al.  Differentiation Between Different Pathological Cerebral Embolic Materials Using Transcranial Doppler in an In Vitro Model , 1993, Stroke.

[14]  T. Treasure,et al.  Detection of middle cerebral emboli during coronary artery bypass surgery using transcranial Doppler sonography. , 1990, Stroke.

[15]  H. Miller,et al.  A prospective evaluation of the Björk-Shiley, Hancock, and Carpentier-Edwards heart valve prostheses. , 1986, Circulation.

[16]  G. Rábago,et al.  Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement. , 1986, The Journal of thoracic and cardiovascular surgery.

[17]  D. Lindblom,et al.  Long-term relative survival rates after heart valve replacement. , 1990, Journal of the American College of Cardiology.

[18]  M. A. Bell,et al.  Brain microemboli during cardiac surgery or aortography , 1990, Annals of neurology.

[19]  M. Brown,et al.  Microscopic air embolism during cerebral angiography and strategies for its avoidance , 1993, The Lancet.

[20]  V. Fuster,et al.  Systemic thromboembolism in mitral and aortic Starr-Edwards prostheses: a 10-19 year follow-up. , 1982, Circulation.

[21]  S. Helps,et al.  The effect of gas emboli on rabbit cerebral blood flow. , 1990, Stroke.

[22]  M P Spencer,et al.  Experiments on decompression bubbles in the circulation using ultrasonic and electromagnetic flowmeters. , 1969, Journal of occupational medicine. : official publication of the Industrial Medical Association.