Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS.

UNLABELLED Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). METHODS AND RESULTS Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121+/-34HU (n=76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58+/-43HU (n=176, p<0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. CONCLUSIONS A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful.

[1]  S. Achenbach,et al.  Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation. , 2005, European heart journal.

[2]  Stephen Schroeder,et al.  Reliability of Differentiating Human Coronary Plaque Morphology Using Contrast-Enhanced Multislice Spiral Computed Tomography: A Comparison With Histology , 2004, Journal of computer assisted tomography.

[3]  C. Meisner,et al.  Accuracy of Density Measurements Within Plaques Located in Artificial Coronary Arteries by X-Ray Multislice CT: Results of a Phantom Study , 2001, Journal of computer assisted tomography.

[4]  J M Tobis,et al.  Variability in tissue characterization of atherosclerotic plaque by intravascular ultrasound: a comparison of four intravascular ultrasound systems. , 1996, American journal of cardiac imaging.

[5]  C. Caussin,et al.  Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular ultrasound. , 2004, The American journal of cardiology.

[6]  Filippo Cademartiri,et al.  Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography , 2005, European Radiology.

[7]  W. Quist,et al.  Noninvasive characterization of plaque morphology using helical computed tomography. , 1998, The Journal of cardiovascular surgery.

[8]  Pedro A. Lemos,et al.  Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed Tomography , 2002, Circulation.

[9]  J. Lima,et al.  34th Bethesda Conference: Task force #3--What is the spectrum of current and emerging techniques for the noninvasive measurement of atherosclerosis? , 2003, Journal of the American College of Cardiology.

[10]  Udo Hoffmann,et al.  Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease: Patient- Versus Segment-Based Analysis , 2004, Circulation.

[11]  M. Reiser,et al.  Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. , 2004, Atherosclerosis.

[12]  P. Yock,et al.  Intravascular ultrasound: novel pathophysiological insights and current clinical applications. , 2001, Circulation.

[13]  Konstantin Nikolaou,et al.  Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. , 2004, Journal of the American College of Cardiology.

[14]  W. Bautz,et al.  Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction , 2003, Circulation.

[15]  C Georg,et al.  Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. , 2001, Journal of the American College of Cardiology.

[16]  Patrick W Serruys,et al.  Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography. , 2005, Journal of the American College of Cardiology.

[17]  M. Gotsman,et al.  Atherosclerosis studies by intracoronary ultrasound. , 1997, Advances in experimental medicine and biology.

[18]  C. Claussen,et al.  Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution , 2005, Heart.

[19]  Konstantin Nikolaou,et al.  Advances in cardiac CT imaging: 64-slice scanner , 2004, The International Journal of Cardiovascular Imaging.

[20]  G. Simonetti,et al.  Accuracy of thin-slice computed tomography in the detection of coronary stenoses. , 2004, European heart journal.

[21]  Richard D. White,et al.  Non-invasive assessment of plaque morphology and remodeling in mildly stenotic coronary segments: comparison of 16-slice computed tomography and intravascular ultrasound , 2003, Coronary artery disease.

[22]  S. Achenbach,et al.  Detection of Calcified and Noncalcified Coronary Atherosclerotic Plaque by Contrast-Enhanced, Submillimeter Multidetector Spiral Computed Tomography: A Segment-Based Comparison With Intravascular Ultrasound , 2003, Circulation.

[23]  Konstantin Nikolaou,et al.  Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT , 2003, European Radiology.

[24]  S. Furui,et al.  Measurement of vascular diameter in vitro by automated software for CT angiography: effects of inner diameter, density of contrast medium, and convolution kernel. , 2004, AJR. American journal of roentgenology.

[25]  Heshui Shi,et al.  Noninvasive Coronary Angiography With Multislice Computed Tomography , 2005 .