Dynamic Voltage Restorer Based on Proportional-resonant Control

A novel double-loop feedback control strategy of DVR based on proportional-resonant control is proposed. Compared with the traditional proportional-integral (PI) controller, the proportional-resonant controller applied to the output compensation voltage control strategy of DVR, can achieve tracking with zero static error for the reference signals of compensation voltage. Based on frequency characteristic analysis of proportional-resonant controller, the feedback control system of DVR in discrete domain introducing control delay is analyzed. Analyses show that the current inner loop using a simple proportional control has reliable stability, and the proportional-resonant control acting on outer voltage loop ensure steady-state accuracy of the system, as well as certain anti-interference ability against load currents. The whole system can obtain high quality steady-state compensation accuracy and fast dynamic response. The simulation results illustrate the correctness of theoretical analysis and the validity of the proposed double-loop feedback control strategy.

[1]  L. Morgan,et al.  Experience with an inverter-based dynamic voltage restorer , 1999 .

[2]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[3]  E. Acha,et al.  A Versatile Control Scheme for a Dynamic Voltage Restorer for Power-Quality Improvement , 2009, IEEE Transactions on Power Delivery.

[4]  San Shing Choi,et al.  Dynamic voltage restoration with minimum energy injection , 2000 .

[5]  H. G. Sarmiento,et al.  A voltage sag study in an industry with adjustable speed drives , 1994, Proceedings of Industrial and Commercial Power Systems Conference.

[6]  Nicholas Jenkins,et al.  Dynamic voltage restorer based on voltage-space-vector PWM control , 2001 .

[7]  San Shing Choi,et al.  Performance improvement of the dynamic voltage restorer with closed-loop load voltage and current-mode control , 2002 .

[8]  San Shing Choi,et al.  Dynamic voltage restoration with minimum energy injection , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[9]  Deepak Divan,et al.  Dynamic sag correctors: cost effective industrial power line conditioning , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[10]  Wu Wei-yang Research on Control Strategy for Single-Phase Grid-connected Inverter , 2007 .