Calibration of cross-sectional images measured by an ultrasound-based muscle evaluation system

The quantification of muscle volume can be used to estimate muscular strength. Therefore, we developed a flexible measuring system for muscle volume using ultrasonog-raphy. In the measuring process, subjects are not required to perform any muscular contraction, so it is completely safe and particularly suitable for elderly people. The ultrasound probe is installed on a mechanical arm, and continuously scans fragmental images along the body surface. The measured images are then composed into a wide area cross-sectional image. However, the muscle area measured by our system was slightly smaller than that measured by MRI. because the ultrasound probe contacted the body surface with a little pressure during the measurement. The strain then decreases the total image size and its circumference. This paper introduces our developed system and proposes a new calibration method for the muscle area in the thigh based on its circumference.

[1]  V. Edgerton,et al.  Physiological cross‐sectional area of human leg muscles based on magnetic resonance imaging , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  Jens E. Wilhjelm,et al.  Visual and quantitative evaluation of selected image combination schemes in ultrasound spatial compound scanning , 2004, IEEE Transactions on Medical Imaging.

[3]  Toshio Tsuji,et al.  Development of practical measuring system for cross-sectional image of human extremities with an ultrasonography , 1998 .

[5]  Kiyotaka Fukumoto,et al.  Development of a Measuring System for Cross-sectional Image of Human Extremities Using Ultrasonography , 2006 .

[6]  G.E. Trahey,et al.  Adaptive imaging and spatial compounding in the presence of aberration , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  A CROSS-SECTIONAL STUDY OF THE SIZE AND STRENGTH OF THE THIGH MUSCLES IN SEDENTARY 259 JAPANESE ADULTS , 1999 .

[8]  C. Lamb,et al.  Ultrasound image compounding: effect on perceived image quality. , 2007, Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association.

[9]  P. Gadeberg,et al.  Volume of ankle dorsiflexors and plantar flexors determined with stereological techniques. , 1999, Journal of applied physiology.

[10]  J P Albright,et al.  Cross-sectional thigh components: computerized tomographic assessment. , 1985, Medicine and science in sports and exercise.

[11]  T. Fukunaga,et al.  The relationship between ball velocity and muscle strength and muscle volume of baseball pitchers , 2006 .