Integrated circuit ESD protection structure failure analysis based on TLP technique

This paper introduces an evaluation method of integrated circuit port protection structure burn-out mechanism basing on transmission line pulse test (TLP). Based on the analysis of a variety of typical ESD protection circuit structures of integrated circuit, the design procedure of TLP test scheme is provided. By establishing functional relation between I/V characteristic curves and the ESD damage failure of protection circuit, the level and consequence of integrated circuit ESD failure can be quantified precisely, the root causes also can be confirmed. With a failure analysis case of a typical clamp protection structure of 0.18μm process verifies the feasibility of the technique.

[1]  Gaudenzio Meneghesso,et al.  ESD robustness of smart-power protection structures evaluated by means of HBM and TLP tests , 2000, 2000 IEEE International Reliability Physics Symposium Proceedings. 38th Annual (Cat. No.00CH37059).

[2]  T. P. Chen,et al.  Reproducibility of transmission line measurement of bipolar I-V characteristics of MOSFETs , 1999, IEEE Trans. Instrum. Meas..

[3]  J.J. Liou,et al.  A method for determining a transmission line pulse shape that produces equivalent results to human body model testing methods , 2000, Electrical Overstress/Electrostatic Discharge Symposium Proceedings 2000 (IEEE Cat. No.00TH8476).

[4]  A. Johnston,et al.  Models for Total Dose Degradation of Linear Integrated Circuits , 1987, IEEE Transactions on Nuclear Science.