Benefits of 3D rotational DSA compared with 2D DSA in the evaluation of intracranial aneurysm.

RATIONALE AND OBJECTIVES The aim of this study was to compare conventional two-dimensional (2D) digital subtraction angiography (DSA) with three-dimensional (3D) rotational DSA in the investigation of intracranial aneurysm in terms of detection, size measurement, neck diameter, neck delineation, and relationship with surrounding vessels. A further aim was to compare radiation dose, contrast volume, and procedural time between the two protocols. MATERIALS AND METHODS Thirty-five patients who presented with subarachnoid bleeds on computed tomography and were suspected of having intracranial aneurysms underwent conventional 2D DSA followed by 3D DSA. The 3D digital subtraction angiographic images were displayed as surface shaded display images. Aneurysm detection, sac size, neck diameter, neck delineation, and relationship of aneurysm to the surrounding vessels analyzed from the two protocols were compared. Radiation dose, contrast volume, and procedural time for both examinations were also compared. RESULTS Three-dimensional DSA detected 44 aneurysms in 31 patients, with negative findings seen in four patients. A false-negative detection rate of 6.8% (three of 44) for 2D DSA was noted. There was no significant difference in aneurysm size between 3D and 2D DSA. The sizes of aneurysm necks were found to be significantly larger in 3D DSA than on 2D DSA. The aneurysm neck and relationship to surrounding vessels were significantly better demonstrated on 3D DSA than on 2D DSA. Radiation dose (entrance surface dose), contrast use, and procedural time with 3D DSA were significantly less than with 2D DSA. CONCLUSIONS Three-dimensional DSA improves the detection and delineation of intracranial aneurysms, with lower radiation dose, less contrast use, and shorter procedural time compared to 2D DSA. The size of the aneurysm neck on 3D DSA tended to be larger than on 2D DSA.

[1]  Kazuyuki Kojima,et al.  Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm. , 2002, AJNR. American journal of neuroradiology.

[2]  C. Cognard,et al.  Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment. , 1998, Radiology.

[3]  Y Trousset,et al.  Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. , 2001, Radiology.

[4]  Uwe Spetzger,et al.  Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms. , 2002, AJNR. American journal of neuroradiology.

[5]  David F Kallmes,et al.  3D cerebral angiography: radiation dose comparison with digital subtraction angiography. , 2005, AJNR. American journal of neuroradiology.

[6]  C. H. Castaño-Duque,et al.  Pre-embolization study of ruptured cerebral aneurysm with rotational and 3D reconstruction angiography , 2002 .

[7]  M. Sluzewski,et al.  3D Rotational Angiography: The New Gold Standard in the Detection of Additional Intracranial Aneurysms , 2008, American Journal of Neuroradiology.

[8]  B. Jones,et al.  Three-dimensional rotational angiography of neurovascular lesions in pediatric patients. , 2006, AJR. American journal of roentgenology.

[9]  J M Wardlaw,et al.  Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort. , 2001, Radiology.

[10]  Toshinori Hirai,et al.  Pseudostenosis phenomenon at volume-rendered three-dimensional digital angiography of intracranial arteries: frequency, location, and effect on image evaluation. , 2004, Radiology.

[11]  Jose I Suarez,et al.  Aneurysmal subarachnoid hemorrhage. , 2006, The New England journal of medicine.

[12]  Yukunori Korogi,et al.  Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms. , 2002, AJNR. American journal of neuroradiology.

[13]  Andreas Raabe,et al.  Three-dimensional rotational angiography guidance for aneurysm surgery. , 2006, Journal of neurosurgery.

[14]  K. Fujii,et al.  Three-dimensional digital subtraction angiography vs two-dimensional digital subtraction angiography for detection of ruptured intracranial aneurysms: a study of 86 aneurysms. , 2005, Neurology India.

[15]  A Workman,et al.  Patient dose from 3D rotational neurovascular studies. , 2007, The British journal of radiology.

[16]  V. Seifert,et al.  Size and location of ruptured and unruptured intracranial aneurysms measured by 3-dimensional rotational angiography. , 2006, Surgical neurology.

[17]  Soon-Seob Ahn,et al.  Three-dimensional digital subtraction angiographic evaluation of aneurysm remnants after clip placement. , 2010, Journal of Korean Neurosurgical Society.

[18]  H. Mori,et al.  Three-dimensional Reconstructed Images after Rotational Angiography in the Evaluation of Intracranial Aneurysms: Surgical Correlation , 2000, Neurosurgery.

[19]  D F Kallmes,et al.  Comparison of 2D Digital Subtraction Angiography and 3D Rotational Angiography in the Evaluation of Dome-to-Neck Ratio , 2009, American Journal of Neuroradiology.