Development and validation of a real-time reduced field of view imaging driven by automated needle detection for MRI-guided interventions

Automatic tracking and scan plane control in MRI-guided therapy is an active area of research. However, there has been little research on tracking needles without the use of external markers. Current methods also do not account for possible needle bending, because the tip does not get tracked explicitly. In this paper, we present a preliminary method to track a biopsy needle in real-time MR images based on its visible susceptibility artifact and automatically adjust the next scan plane in a closed loop to keep the needle's tip in the field of view. The images were acquired with a Single Shot Fast Spin Echo (SSFSE) sequence combined with a reduced field of view (rFOV) technique using 2D RF pulses, which allows a reduction in scan time without compromising spatial resolution. The needle tracking software was implemented as a plug-in module for open-source medical image visualization software 3D Slicer to display the current scan plane with the highlighted needle. Tests using a gel phantom and an ex vivo tissue sample are reported and evaluated in respect to performance and accuracy. The results proved that the method allows an image update rate of one frame per second with a root mean squared error within 4 mm. The proposed method may therefore be feasible in MRI-guided targeted therapy, such as prostate biopsies.

[1]  Rolf W. Günther,et al.  A perspective on needle artifacts in MRI: an electromagnetic model for experimentally separating susceptibility effects , 2000, IEEE Transactions on Medical Imaging.

[2]  M. Bock,et al.  Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation , 2008, Magnetic resonance in medicine.

[3]  Zion Tsz Ho Tse,et al.  System for 3-D Real-Time Tracking of MRI-Compatible Devices by Image Processing , 2008, IEEE/ASME Transactions on Mechatronics.

[4]  Eigil Samset,et al.  Dynamic MRI Scan Plane Control for Passive Tracking of Instruments and Devices , 2007, MICCAI.

[5]  D. Beyersdorff,et al.  MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. , 2005, Radiology.

[6]  Gabor Fichtinger,et al.  Pneumatically operated MRI-compatible needle placement robot for prostate interventions , 2008, 2008 IEEE International Conference on Robotics and Automation.

[7]  Gabor Fichtinger,et al.  Robotic Assistant for Transperineal Prostate Interventions in 3T Closed MRI , 2007, MICCAI.

[8]  Haiying Liu,et al.  Interventional MRI at high‐field (1.5 T): Needle artifacts , 1998, Journal of magnetic resonance imaging : JMRI.

[9]  A.A. Goldenberg,et al.  Robotic System for Closed-Bore MRI-Guided Prostatic Interventions , 2008, IEEE/ASME Transactions on Mechatronics.

[10]  H. Weiss,et al.  Visualization of magnetic resonance-compatible needles at 1.5 and 0.2 Tesla , 1996, CardioVascular and Interventional Radiology.

[11]  J.M. Santos,et al.  Flexible real-time magnetic resonance imaging framework , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Bruno Madore,et al.  Reduced field‐of‐view MRI with two‐dimensional spatially‐selective RF excitation and UNFOLD , 2005, Magnetic resonance in medicine.

[13]  Gabor Fichtinger,et al.  Design of a novel MRI compatible manipulator for image guided prostate interventions , 2005, IEEE Transactions on Biomedical Engineering.

[14]  W. Eric L. Grimson,et al.  An Integrated Visualization System for Surgical Planning and Guidance Using Image Fusion and Interventional Imaging , 1999, MICCAI.

[15]  Gabor Fichtinger,et al.  OpenIGTLink: an open network protocol for image‐guided therapy environment , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[16]  J. Lewin,et al.  Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. , 1996, AJR. American journal of roentgenology.

[17]  Gabor Fichtinger,et al.  A hybrid method for 6-DOF tracking of MRI-compatible robotic interventional devices , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[18]  P Boesiger,et al.  Biopsy needle susceptibility artifacts , 1996, Magnetic resonance in medicine.

[19]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.